Skip to main content Skip to search Skip to main navigation

GX-SE External Gas Sensor for Natural Gas/CNG

The external gas sensor for town gas, natural gas and LPG: accessory for the GX-A1 and GX-HS gas detectors, positioned according to the type of gas

The Schabus GX-SE is an external gas sensor for town gas and natural gas (methane), as well as for LPG (propane, butane) and R290. It is used as an accessory with the GX-A1 and GX-HS gas detectors from the Schabus product range and detects natural gas from leaks in the building installation as well as cylinder gas from leaking fittings. The sensor is connected via an RJ plug connection on the cable and operates in dry indoor areas.

The GX-SE is small, consumes little power and can be integrated into Schabus gas warning systems. Because methane is lighter than air and LPG is heavier than air, the sensor is mounted at the ceiling or just above the floor depending on the type of gas. The connection cable can be extended.

⚠️

Important note: The GX-SE is an accessory sensor and can only be used in conjunction with the GX-A1 or GX-HS gas detectors. It is not a standalone gas detector. The sensor may only be used in dry indoor areas and never in potentially explosive areas. Installation must be carried out by a qualified professional. Do not open the device; it contains no user-serviceable parts.

💡

Good to know: Be sure to observe the required position of the sensor. The correct height depends on the type of gas. For your own safety, ask your utility company about the type of gas present and its properties.

Detect gas leaks early

🔥

Town gas and natural gas

Detects natural gas (methane) from leaks in the building installation.

🛢️

LPG

Detects cylinder gas (propane, butane) from leaking fittings as well as R290.

🔗

For GX-A1 and GX-HS

External sensor as an accessory for the GX-A1 and GX-HS gas detectors, can be integrated into Schabus gas warning systems.

🔌

RJ plug connection

The connection to the gas detector is made via an RJ plug connection on the cable.

📏

Freely positionable

Up to 4 m from the gas detector, near the ceiling or near the floor depending on the type of gas.

📐

Extendable cable

The connection cable can be extended with 3-core cable, up to 20 m depending on the cross-section.

🔋

Small and economical

Small size and low power consumption.

What is included in the box

The GX-SE has no options and no additional variants. Mounting material is included. The GX-A1 or GX-HS gas detector is not included.

  • Gas sensor GX-SE with connection cable
  • Mounting material (wall plug, screw)
  • Operating instructions

How the GX-SE is constructed

The GX-SE consists of a compact sensor housing with connection cable. The device contains no user-serviceable parts and must not be opened.

1

Sensor housing with ventilation slots

Room air reaches the sensor through the slots in the housing. For this reason, it must not be mounted behind curtains or in cupboards and must remain protected from dust and dirt.

2

Mounting tab

The sensor is attached to the wall using the enclosed mounting material (wall plug, screw).

3

Connection cable with RJ plug connection

The cable connects the sensor to the GX-A1 or GX-HS gas detector. It can be extended and must be firmly installed as surface-mounted cable.

4

Printed test date

A test date (month/year) is printed on the sensor, which you should observe.

The correct position depending on the type of gas

The sensor may only be installed in dry indoor areas and must be positioned correctly depending on the gas type so that the warning device works properly. Installation must be carried out by a qualified professional.

⬆️

Town gas and natural gas (methane)

Mount the sensor 15 to 30 cm below the room ceiling, but no more than 4 m from the gas detector. It must be positioned above the highest door or window opening in the room. Methane is lighter than air and always rises upwards.

⬇️

LPG (propane, butane)

Mount the sensor a maximum of 15 cm above the floor, but no more than 4 m from the gas detector. LPG is heavier than air, sinks to the floor and spreads there similarly to water.

The sensor must not be mounted in the following locations

  • In places that could prevent the alarm from being triggered in the event of a gas leak, for example behind curtains or in cupboards
  • Directly next to a hob or above a washbasin
  • Next to a door, windows, ventilation, a fan, air conditioning or similar
  • In areas where dust or dirt could put the sensor out of operation
  • In potentially explosive areas

Extending the connection cable

  • The connection cable can be extended; a 3-core cable must be used for this
  • With 3 × 0.75 mm², the maximum length is 10 m; with 3 × 1.5 mm², a maximum of 20 m
  • At least 5 V (±0.1 V) must be present at the sensor; please observe this without fail
  • The manufacturer recommends the LIYY control cable (article 300780) for extension
  • The sensor cable must be firmly installed as surface-mounted cable

What to do in the event of a gas alarm

This applies in the event of an alarm from the gas detector and also when you can smell gas.

  1. Do not unplug the warning device.
  2. Do not operate any further electrical devices.
  3. Do not light an open flame and extinguish open fires.
  4. Ensure fresh air: stay calm, open all doors and windows and ventilate the room or house thoroughly.
  5. If the alarm continues or sounds again, evacuate the building and leave all windows and doors open. Make sure that everyone in the house has been warned.
  6. Check the room or house for possible sources of fire.
  7. Shut off the main gas supply and ensure that the cause of the gas leak is eliminated.
  8. In the event of a persistent or repeated alarm, contact your energy supply professional or the fire brigade.

Check, maintain, avoid false alarms

Function test

  1. The manufacturer recommends a monthly function test.
  2. For this, for example, hold a butane lighter (without a flame) at least 10 to 20 cm above the sensor and let the escaping gas sink onto the sensor for a short moment.
  3. Further information can be found in the operating instructions of the gas detector.
  4. Never expose the sensor to pure gas from refill bottles, cartridges or gas lighters; this would destroy it.

Possible causes of false alarms

  • The sensitive sensor also reacts to other gaseous media
  • Aerosols, for example propellant gas in hairsprays or disinfectant sprays
  • Heavy tobacco smoke, for example during a smoking card game, and cooking fumes
  • Rapidly changing environmental conditions such as humidity, temperature fluctuations or draughts

Cleaning and care

  • Clean the sensor of dust regularly
  • Avoid exposing the device to moisture (splash or rain water), dust and direct sunlight
  • Clean the device only with a dry linen cloth; if heavily soiled, it may be slightly dampened
  • Do not use cleaning agents containing solvents
  • Observe the test date (month/year) indicated on the sensor

Suitable devices and accessories

The GX-SE itself has no options. It is operated with one of the following gas detectors from the Schabus product range.

  • Gas detector GX-A1
    Required: the GX-SE is connected to this gas detector as an external sensor
  • Gas detector GX-HS
    Required: alternatively, the GX-SE can also be connected to this gas detector
  • LIYY control cable (article 300780)
    Recommended by the manufacturer for extending the sensor cable

What the GX-SE is not

  • It is not a standalone gas detector, but an accessory sensor for the GX-A1 and GX-HS
  • It is only intended for dry indoor areas and not for potentially explosive areas
  • It does not trigger on carbon monoxide (CO) and does not replace a CO detector
  • Frequent and high gas concentrations reduce sensitivity over time and shorten service life
  • It must never be exposed to pure refrigerant gas or pure gas from refill bottles, cartridges or gas lighters
  • The manufacturer is not liable for damage and losses of any kind resulting from no alarm signal being issued by the gas detector despite an increased gas concentration

Manufacturer’s notes

  • Read the operating instructions carefully before installation and initial commissioning, follow the safety instructions in particular and keep the manual
  • Installation must be carried out by a qualified professional
  • Packaging material is not a toy; keep it away from children
  • Do not open the device; it contains no user-serviceable parts
  • The device is intended for use in residential buildings, in retail spaces such as shops and supermarkets, and in small businesses such as workshops and service centres, in each case connected to the public low-voltage grid
  • The device is not approved for any use other than that described

Conformity and disposal

The product fulfils the statutory, national and European requirements and bears the CE marking. You can find the declaration of conformity on the manufacturer’s website.

The GX-SE does not belong in household waste. The crossed-out wheelie bin symbol reminds you to use the take-back systems so that the materials can be reused in an environmentally friendly manner at the end of their service life (WEEE reg. no. DE91394868). For further information, contact your city’s waste advisory service or the manufacturer.

Why the GX-SE is suitable

Several fuel gases

Detects natural gas, town gas, LPG (propane, butane) and R290.

Safety in the event of leaks

Protects against leaks in the building installation and leaking fittings on cylinder gas.

Easy to integrate

RJ plug connection, mounting material included, compatible with GX-A1 and GX-HS.

Small and economical

Small size, low power consumption, flexibly positionable.

Flexible cable

Connection cable extendable up to 20 m, depending on cable cross-section.

From the manufacturer

Made in Germany, German manufacturer since 1992, personal expert advice without a call centre, ISO 9001:2015 certified.

Areas of application

  • Heating rooms
  • Rooms with gas installation
  • Rooms with cylinder gas (propane, butane)
  • Kitchens and catering
  • Living spaces and motorhomes
  • Workshops and small businesses

Frequently asked questions

Can I operate the GX-SE on its own?

No. The GX-SE is an external sensor and is used as an accessory with the GX-A1 or GX-HS gas detectors. It is connected via the RJ plug connection on the cable.

Which gases does the GX-SE detect?

Town gas and natural gas (methane), LPG (propane, butane) and R290. The sensor does not trigger on carbon monoxide (CO).

Where do I mount the sensor?

For town gas and natural gas (methane), 15 to 30 cm below the room ceiling and above the highest door or window opening; for LPG, a maximum of 15 cm above the floor. In both cases, no more than 4 m from the gas detector and only in dry indoor areas.

Where must the sensor not be mounted?

Not behind curtains or in cupboards, not directly next to a hob or above a washbasin, not next to doors, windows, ventilation, a fan or air conditioning, not in dusty or dirty areas and not in potentially explosive areas.

Can I extend the connection cable?

Yes, with a 3-core cable: with 3 × 0.75 mm² up to a maximum of 10 m, with 3 × 1.5 mm² up to a maximum of 20 m. At least 5 V (±0.1 V) must be present at the sensor. The manufacturer recommends the LIYY control cable (article 300780). The sensor cable must be firmly installed as surface-mounted cable.

How do I check the function?

The manufacturer recommends a monthly test. Hold a butane lighter without a flame at least 10 to 20 cm above the sensor and let the escaping gas sink briefly onto the sensor. Never expose the sensor to pure gas; this would destroy it.

Why is there a false alarm?

The sensitive sensor also reacts to other gaseous media. Aerosols such as hair or disinfectant spray, heavy tobacco smoke and cooking fumes can trigger a false alarm, as can rapidly changing humidity, temperature fluctuations or draughts. Clean the sensor of dust regularly.

What should I do in the event of a gas alarm?

Do not unplug the warning device, do not switch on any further electrical devices, do not light an open flame, open doors and windows and ventilate thoroughly. If the alarm continues, evacuate the building and warn everyone. Shut off the main gas supply and, in the event of a persistent or repeated alarm, contact your energy supply professional or the fire brigade.

Do high gas concentrations affect the sensor?

Yes. Frequent and high gas concentrations reduce the sensitivity of the sensor over time and shorten its service life. Also observe the test date (month/year) indicated on the sensor.

Are there options or additional variants?

No. The GX-SE (article number 200897-SE) has no options. Mounting material (wall plug, screw) is included in the scope of delivery; the GX-A1 or GX-HS gas detector is required separately.

Questions about the GX-SE gas sensor?

Our support team in Germany provides free advice on selection, installation and configuration.

Datasheets
Datasheet 1

Oops! Your browser doesn't support PDFs!

Datasheet 1 (948.13 KB)

GX-SE Gas Sensor for City, Natural, and LPG Gas

Measured gases

  • Methane (natural gas, city gas)
  • Propane / isobutane (LPG)
  • Ethanol / acetone

Sensor characteristics

  • Sensor type: catalytic gas sensor
  • Operating voltage: 5 V DC ±0.1 V
  • Ambient humidity: 5–90 % RH (non‑condensing)
  • Operating temperature range: −10 °C to +50 °C
  • Storage temperature: −20 °C to +70 °C
  • Service life: approx. 5 years

Trigger concentrations

  • CO: no response
  • Methane: <5000 ppm (0.5 %)
  • Propane / isobutane: <2000 ppm (0.2 %)
  • Ethanol / acetone: <5000 ppm (0.5 %)

Electrical connections

  • Wire configuration:
    • Brown: Vin +
    • White: VOut
    • Green: GND

General technical data

  • Protection rating: IP20
  • Cable length: 2.5 m
  • Cable diameter: 3.5 mm
  • Dimensions (H × W × D): 52 × 27 × 29 mm

Manufacturer information:

Electrical engineering Schabus GmbH & Co. KG

Baierbacher Straße 150

83071 Stephanskirchen
Germany

Telephone: +49 80 36 / 674 979 – 0

Email: info@elektrotechnik-schabus.de

Responsible person:

Didactum® Security GmbH

Im Mühlenfeld 4

48163 Münster
Deutschland

Fon: (+49) 250 19 71 63 54 / (+49) 171 33 11 577

Email: info@didactum-security.de

Questions?

You have questions about Schabus products?

You would like a quote?

Contact us