€79.83
The external carbon monoxide sensor for technical monitoring – Accessory for the GX-A1+ and GX-HS gas warning devices
The Schabus GX-CO is an external gas sensor for the detection of carbon monoxide (CO) and smoke in the ambient air. It is used as an accessory for the GX-A1+ and GX-HS gas warning devices and is connected via an RJ plug connection on the cable.
In combination with the gas warning control units, the sensor enables continuous monitoring of technical installations with potential CO sources, for example in boiler rooms, technical rooms or underground car parks. It is compact, has low power consumption and can be easily integrated into Schabus gas warning systems.
The GX-CO must not be used in potentially explosive atmospheres.
Important note: The GX-CO may only be used in conjunction with a GX-A1+ or GX-HS gas warning device. It is a technical monitoring sensor for gas warning control units and does not replace a stand-alone, standard-tested CO alarm for direct personal protection. It must not be used in potentially explosive atmospheres. Installation must be carried out by a qualified specialist.
Danger detected – danger averted
The GX-CO reports carbon monoxide and smoke at an early stage to the connected gas warning device.
CO and smoke detection
External gas sensor for the detection of carbon monoxide (CO) and smoke in the ambient air.
RJ plug connection
The cable is equipped with an RJ plug connection, making integration into GX-A1+ and GX-HS simple.
2.5 m sensor cable
The connection cable can be extended if required. The minimum cross-sections must be observed.
Wide spectrum
The sensor has high cross-sensitivities and reacts differently depending on the medium to various gases and vapours.
Compact and robust
Small size, low power consumption and robust design.
For technical installations
For boiler rooms, technical rooms, underground car parks, workshops and buildings with potential CO sources.
Made in Germany
Directly from the manufacturer Elektrotechnik Schabus, including repair and spare parts.
Why CO monitoring is crucial
Carbon monoxide is imperceptible. Early detection helps to recognise hazards in good time.
- Carbon monoxide is colourless, odourless and tasteless
- It is produced by incomplete combustion
- It is harmful to health even at low concentrations
- Carbon monoxide is also produced during the development of smoke from fires
Typical sources of danger
- Gas and oil heating systems
- Open fireplaces
- Wood-burning stoves
- Combustion engines
- Emergency power generators
- Combined heat and power plants
How the sensor works
The GX-CO monitors the ambient air and supplies the measurement signal to the connected gas warning device.
- The sensor is powered and connected via the GX-A1+ or GX-HS gas warning device
- It continuously monitors the ambient air for carbon monoxide and smoke
- The gas warning device evaluates the signal and warns in the event of elevated concentrations
- The sensor reacts differentially depending on the medium to various gases and vapours
- It shows particularly high sensitivity to alcohols and organic solvents
- Increased sensitivity also exists to ethanol vapour and alcohol vapours
- The sensitivity diagram in the operating instructions shows the sensitivity profile to ethanol vapour as well as to various gases and vapours
- This cross-sensitivity must be taken into account when installing in corresponding environments
What is included in the box
The sensor is supplied with sensor cable and mounting material.
- Gas sensor GX-CO
- Mounting material (screw & wall plug)
- Operating instructions
Only usable in conjunction with GX-A1+ or GX-HS.
How the GX-CO is constructed
The GX-CO is a compact external sensor with a permanently connected supply cable.
Compact sensor housing
The light-coloured plastic housing carries a label on the front with the type designation GX-CO and a note on sensor mounting and the operating instructions. It is intended only for dry indoor rooms. A test date is also indicated on the sensor.
Ventilation slots
Ventilation slots are located on the housing through which the ambient air reaches the sensor element. They must not be covered, and dust or dirt must not clog them.
Mounting tab
A mounting tab with a hole is located at the bottom of the housing. The sensor is fastened with the screw and wall plug included in the scope of delivery.
Connection cable with RJ plug connection
The sensor cable is 2.5 m long and permanently connected to the sensor. The cores: brown = Vin+, white = VOut, green = GND. The RJ plug connection on the cable is used for connection to the gas warning device.
Mounting and connection
Installation must be carried out by a qualified specialist. Read the operating instructions thoroughly before mounting and commissioning and follow the safety instructions.
Positioning the sensor
- Install the sensor only in dry indoor rooms and position it correctly according to the type of gas to ensure proper functioning of the warning device.
- Mount the external sensor as close as possible to the combustion appliance to be monitored or to the flue, fireplace or chimney, but approx. 15–30 cm below the ceiling, as the escaping gases are heated and initially rise upwards.
- The prescribed mounting height must be strictly observed.
- The sensor cable must be permanently installed as surface-mounted wiring.
Connecting the sensor
- Connect the sensor to the GX-A1+ or GX-HS gas warning device via the RJ plug connection. Connection is described in the operating instructions of the gas warning device.
Extending the sensor cable
The sensor cables are 2.5 m long as standard. A 3-core cable must be used for extension. The following minimum cross-sections apply:
- 3 × 0.75 mm²: maximum length 10 m
- 3 × 1.5 mm²: maximum length 20 m
For extension, the manufacturer recommends the control cable LIYY (Art. No. 300780).
Please note carefully: At the transfer point to the sensor, at least 5 V ± 0.1 V must be present, even with an extended cable (e.g. 20 m between gas detector and sensor).
Do not mount
The sensor must not be mounted in the following locations:
- Places that could prevent alarm activation in the event of a gas leak (e.g. behind curtains or in cupboards)
- Directly next to a cooker or above a sink
- Next to a door, windows, ventilation, fan, air conditioning, etc.
- In areas where dust or dirt can put the sensor out of operation
- In potentially explosive atmospheres
Function test, false alarms and behaviour in the event of an alarm
Function test and care
- For safety reasons, the manufacturer recommends carrying out the function test monthly
- Clean the sensor regularly by blowing off the dust
- Observe the test date indicated on the sensor and return the sensor to Elektrotechnik Schabus for factory testing and replacement
- Avoid moisture (splash or rain water), dust and direct sunlight on the device
- Clean only with a dry linen cloth; if heavily soiled, slightly dampened; no solvent-based cleaning agents
False alarms
The sensitive sensor of the system also responds to other gaseous media. The following can lead to a false alarm:
- The use of aerosols (propellant gas in sprays for hair, disinfection, etc.)
- Heavy tobacco smoke (e.g. a smoking card party)
- Cooking fumes
Behaviour in the event of an alarm
- Do not unplug the warning device
- Do not switch on any further electrical appliances
- Do not light any open flames or extinguish open fires
- Ensure fresh air: remain calm, open all doors and windows and thoroughly ventilate the room or house
- If the alarm continues or occurs again, evacuate the building and leave all windows and doors open. Ensure that all persons in the house are warned
- Investigate the room or house for possible sources of fire
- Carbon monoxide is produced during the development of smoke from fires. Important: All persons must leave the house
- Eliminate the cause of the gas leak. In case of uncertainty, contact the energy supply specialist
- In the event of a persistent or repeated alarm, contact the energy supply specialist or the fire brigade
- Provide medical help for anyone showing symptoms of carbon monoxide poisoning and point out that inhalation of carbon monoxide is suspected
- Only put the combustion appliance back into operation after it has been checked by a competent person and released for use again
Manufacturer’s notes
- Read the operating instructions thoroughly before mounting and commissioning and keep them; they form part of the product
- The sensor is a technical monitoring sensor and does not replace a stand-alone, standard-tested CO alarm for direct personal protection
- The sensor is not suitable for potentially explosive atmospheres
- The sensor is intended only for dry indoor rooms
- Do not open the device; it contains no parts that can be maintained by the user
- Packaging material is not a toy and must be kept away from children
- The device is not approved for any use other than that described
- Intended for residential areas (houses, flats, rooms), commercial and business premises (shops, hypermarkets), small businesses (workshops, service centres) with connection to the public low-voltage network
- The manufacturer is not liable for damage or losses of any kind, e.g. individual or consequential damage, resulting from the fact that no alarm signal is given by the gas detector despite elevated gas concentration
- The declaration of conformity is available for download on the manufacturer’s website
Warranty, guarantee, return and disposal
The device is covered by the statutory warranty of at least 2 years in the EU. The manufacturer Elektrotechnik Schabus additionally offers a 5-year guarantee that can be registered online. There is a right of withdrawal of 14 days. Repair and spare parts are available directly from the manufacturer, even beyond the statutory warranty.
The manufacturer repairs or replaces the device free of charge in the event of a warranty claim if the following is fulfilled: The device is sent in with a description of the fault, proof of purchase and address and delivery address (name, telephone number, street, house number, postcode, city, country), adequately packed (the manufacturer accepts no liability for damage or loss during shipping) and used in accordance with the operating instructions. No liability is accepted for damage caused by accident, misuse, modification or negligence.
In the event of a defect, please contact the manufacturer and provide your complete address and the reason for return. Within Germany you will receive a free return label by e-mail. Carriage forward packages will not be accepted; unjustified returns that do not constitute a complaint will be charged subsequently.
The device does not belong in household waste. The crossed-out wheeled bin symbol reminds you to use the take-back systems for waste electrical and electronic equipment (WEEE No. 91394868). The product may contain substances that are hazardous to health and the environment. Information on collection, reuse and recycling systems can be obtained from your local waste advisory service or from the manufacturer.
Why the GX-CO is suitable
For CO and smoke
Detection of carbon monoxide and smoke in technical installations.
Simple integration
Quickly integrable into Schabus gas warning systems, connection via RJ plug connection.
Compact design
Small size and low power consumption.
Flexible cable length
2.5 m sensor cable, extendable up to 20 m with appropriate cross-section.
Clear limits of use
Limits of use, mounting instructions and behaviour in the event of an alarm are clearly described.
Made in Germany
Repair and spare parts directly from the manufacturer.
Areas of application
- Boiler rooms with gas or oil burners
- Rooms with open fireplaces or wood-burning stoves
- Underground car parks
- Workshops with running combustion engines
- Installations with emergency power generators
- Installations with combined heat and power plants
- Technical rooms
- Residential buildings with potential CO sources
The Schabus GX-CO monitors technical installations with potential CO sources and reports carbon monoxide and smoke to the connected gas warning device.
Gas warning devices with which the GX-CO is operated
- GX-A1+ – Gas warning control unit from Schabus
- GX-HS – Signalling device from Schabus
Frequently asked questions
With which devices can the GX-CO be operated?
The GX-CO may only be used in conjunction with the GX-A1+ or GX-HS gas warning devices. It is an external sensor and is connected via an RJ plug connection. Connection is described in the operating instructions of the respective gas warning device.
Does the GX-CO replace a CO alarm?
No. The GX-CO is a technical monitoring sensor for gas warning control units. It does not replace a stand-alone, standard-tested CO alarm for direct personal protection.
Where must the sensor be mounted?
As close as possible to the combustion appliance to be monitored or to the flue, fireplace or chimney, but approx. 15–30 cm below the ceiling. The prescribed mounting height must be strictly observed, and the sensor cable must be permanently installed as surface-mounted wiring.
May the sensor be used in potentially explosive atmospheres?
No. The GX-CO must not be used in potentially explosive atmospheres. It is intended only for dry indoor rooms.
How is the cable assigned?
Brown = Vin+, white = VOut, green = GND. The RJ plug connection on the cable is used for connection to the gas warning device.
Can I extend the sensor cable?
Yes. A 3-core cable must be used for extension: With 3 × 0.75 mm² the maximum length is 10 m, with 3 × 1.5 mm² a maximum of 20 m. At the transfer point to the sensor, at least 5 V ± 0.1 V must be present. The manufacturer recommends the control cable LIYY (Art. No. 300780).
Does the sensor also react to other gases?
Yes. The sensor reacts differently depending on the medium to various gases and vapours. It shows particularly high sensitivity to alcohols, ethanol vapour and organic solvents. This must be taken into account when installing in corresponding environments.
Where can a false alarm come from?
The use of aerosols (propellant gas in sprays for hair, disinfection, etc.), heavy tobacco smoke (e.g. a smoking card party) and cooking fumes can lead to a false alarm.
How do I care for and test the sensor?
The manufacturer recommends carrying out the function test monthly. Regularly remove dust from the sensor by blowing. Observe the test date on the sensor and return the sensor to Elektrotechnik Schabus for factory testing and replacement. For cleaning the housing, use only a dry linen cloth; if heavily soiled, slightly dampened; no solvent-based cleaning agents.
What should I do in the event of an alarm?
Do not unplug the warning device, do not switch on any further electrical appliances and do not light any open flames. Ensure fresh air, open all doors and windows and ventilate thoroughly. If the alarm continues or occurs again, evacuate the building and warn all persons. In the event of symptoms of carbon monoxide poisoning, seek medical help and point out the suspicion. In the event of a persistent or repeated alarm, contact the energy supply specialist or the fire brigade. Only put the combustion appliance back into operation after release by a competent person.
How long is the guarantee valid?
The statutory warranty of at least 2 years applies in the EU. In addition, the manufacturer Schabus offers a 5-year guarantee that can be registered online.
What do I do in the event of a defect?
Contact the manufacturer and provide your complete address and the reason for return. Within Germany you will receive a free return label by e-mail. Carriage forward packages will not be accepted. In the event of a statutory warranty claim, the device must be sent in with a description of the fault, proof of purchase and address and delivery address.
Questions about the GX-CO carbon monoxide sensor?
Our support team in Germany will advise you free of charge on selection, installation and configuration.
Gas Sensor GX-CO
The GX-CO gas sensor is designed for the detection of carbon monoxide (CO) and operates catalytically. Its service life depends on environmental conditions; please observe the inspection date.
Technical Data
- Operating voltage: 5 V ± 0.1 V
- Operating range: -10 °C to +40 °C
- Storage temperature: -20 °C to +50 °C
- Protection class: IP 20
- Dimensions (W×H×D): 52 × 27 × 29 mm
- Power consumption: 300 mA @ 5 V
- Weight: 0.08 kg
- Cable: 2.5 m, 3 × 0.75 mm²
- Humidity: 10–90 % RH, non-condensing
- Trigger concentration: 80–200 ppm / approx. 2.5 V, depending on temperature
- Sensor type: catalytic
Manufacturer information:
Electrical engineering Schabus GmbH & Co. KG
Baierbacher Straße 150
83071 Stephanskirchen
Germany
Telephone: +49 80 36 / 674 979 – 0
Email: info@elektrotechnik-schabus.de
Responsible person:
Didactum® Security GmbH
Im Mühlenfeld 4
48163 Münster
Deutschland
Fon:
(+49) 250 19 71 63 54 / (+49) 171 33 11 577
Email: info@didactum-security.de