Gas Alarm GX-D250

The professional CO₂ detector with display and relays: keep an eye on indoor air, control ventilation automatically

The Schabus Professional CO₂ Detector GX-D250 is a CO₂ warning device for permanent installation in residential and office spaces and in rooms with regular occupancy, for example classrooms, offices, meeting rooms, medical practices or public facilities. An external, high-precision NDIR infrared sensor continuously measures the CO₂ concentration. An illuminated plain-text display shows the exact ppm value and evaluates the indoor air in understandable language, for example with “good air”. The GX-D250 was developed to detect spent exhaled air and to provide guidance for better ventilation behaviour.

The detector warns in three stages: From as low as 800 ppm the display indicates the need to ventilate. The pre-alarm follows at 1,000 ppm with a discreet acoustic warning; the highest alarm level is at 2,500 ppm CO₂ in line with occupational safety (half MAK). In addition, the device has two potential-free changeover relays: one switches on alarm and can, for example, activate forced ventilation or close a solenoid shut-off valve; the other reports faults to the building management system. This makes the GX-D250 not only a detector but a building block for automatic ventilation management.

The GX-D250 is permanently installed on the wall; installation must be carried out by a qualified specialist. The device has no options or variants.

⚠️

Important note: The GX-D250 is not suitable for monitoring CO₂ from technical systems under pressure or for dry-ice processing. It may only be installed in dry indoor rooms and not in potentially explosive atmospheres. Installation must be carried out by a qualified specialist; please observe the five safety rules. For applications with significantly elevated CO₂ concentrations, the manufacturer recommends the GX-D500 or GX-D500P with alarm thresholds in the percentage range.

Measure, display, warn, switch

The GX-D250 clearly reminds you to ventilate and passes its knowledge on to your technology via two relays.

🖥️

Plain-text display

The illuminated display shows the exact CO₂ concentration in ppm and evaluates the air in plain text, e.g. up to 800 ppm “good air”.

🔬

External NDIR sensor

The high-precision infrared sensor is long-lasting and can be mounted independently of the control unit at nose height in the occupancy area.

📏

Three warning levels

Ventilation advice from 800 ppm on the display, pre-alarm from 1,000 ppm, main alarm from 2,500 ppm CO₂ (half MAK).

🚨

Acoustic and visual

Discreet double beep during the pre-alarm, loud continuous tone during the main alarm, plus a flashing LED.

🔀

Alarm relay

A potential-free changeover relay switches on alarm and controls, for example, forced ventilation, ventilation flaps or solenoid shut-off valves.

🏢

Fault relay

A second potential-free changeover relay reports technical faults, e.g. to the building management system or home automation.

🧠

Permanent self-monitoring

A 32-bit microcontroller continuously monitors the system at around 300 points in hardware and software.

📊

Transparent operating data

The display shows current values, status messages, alarm history, temperature monitoring and error codes.

⚙️

Adjustable thresholds

The alarm thresholds are factory-defined and can be customised at the factory on request.

🇩🇪

Made in Germany

Developed and manufactured by Elektrotechnik Schabus from Upper Bavaria; every device is extensively tested before delivery.

Measure at nose height, display at eye level

With the GX-D250 the measuring point and the display are separate. The sensor measures where people breathe; the control unit is mounted so that the display is easy to read while standing. The sensor cable can be extended up to 50 m. Via the height of the sensor you set the response behaviour:

  • Mounted lower the sensor reacts more sensitively
  • Mounted higher the sensor reacts more tolerantly

What’s in the box

  • GX-D250 CO₂ warning device with pre-mounted external sensor
  • Mounting material
  • Operating instructions

How the GX-D250 is constructed

The GX-D250 consists of the control unit in a surface-mounted housing and the external sensor, which is connected via a cable. The sensor is already pre-mounted.

1

Surface-mounted housing

The control unit consists of a base shell and front panel, closed with four housing screws. The base shell is mounted on the wall; the mounting material is included.

2

Illuminated plain-text display

Shows the evaluation of the indoor air and the exact ppm value. By pressing a button you call up further displays, for example device type, software version, operating time and the last error code.

3

SERVICE and RESET | TEST buttons

With SERVICE you scroll through the displays and in the event of a fault retrieve the error number. RESET | TEST checks the alarm transmitter, mutes the alarm tone and resets the fault relay.

4

Three status LEDs

Operate (green) indicates operation, Error (yellow) a fault and Alarm (red) pre-alarm or alarm.

5

Acoustic alarm transmitter

Emits a discreet double beep during the pre-alarm and a loud continuous tone during the main alarm. In the event of a fault it beeps briefly every 10 seconds.

6

Terminals inside the housing

Under the front panel are the terminals for the mains voltage, for the alarm relay Re1 (left), the fault relay Re2 (right) and for the sensor. Each relay provides a common contact (C), a normally closed contact (NC) and a normally open contact (NO).

7

External NDIR sensor with cable

The sensor unit with ventilation slots contains the infrared sensor and is placed at nose height in the occupancy area. Signal transmission to the control unit is digital via pulse-width modulation, ensuring precise, low-interference measurement results.

Install correctly and put into operation

Read the operating instructions thoroughly before installation and first commissioning. Installation must be carried out by a qualified specialist. The device may only be installed on a wall in dry indoor rooms.

Wall mounting

  1. Loosen the four housing screws and remove the front panel. If necessary, unplug the ribbon cable at the connector.
  2. Fasten the base shell of the housing to the wall with the enclosed mounting material. The mounting position “at medium height” is chosen so that the display is easy to read while standing.
  3. Install the connection cables leading to the gas detector firmly as surface-mounted cables.
  4. Connect the mains voltage, relays and sensor to the terminals, then refit and screw on the front panel.

Connecting the relays correctly

🔀

Alarm relay Re1

Switches on alarm, e.g. for forced ventilation, ventilation flaps or solenoid shut-off valves.

🏢

Fault relay Re2

Reports faults to the building management system or home automation.

✅

Idle state

In monitoring mode the relay is “energised”: normally open contact closed, normally closed contact open.

🔴

Alarm or fault

The relay “drops out”: normally open contact open, normally closed contact closed. The switching current of 5 amperes must never be exceeded.

Commissioning step by step

  1. Ventilate the room well before commissioning.
  2. Apply the operating voltage. The display greets you with the manufacturer’s name and device type while all self-tests are completed.
  3. Wait for the start phase of 5 minutes. During this time the GX-D250 performs function tests, the external sensor is pre-heated and the software checks itself. The display shows “CO₂: Wait / Prepairing”. Move away from the sensor during the start phase so as not to falsify the starting values.
  4. When the green LED lights alone, the warning system is in order and ready for operation.

Even after a short power failure the function test is restarted.

How the GX-D250 evaluates the indoor air

Fresh outdoor air is around 400 to 410 ppm. Depending on the concentration the GX-D250 displays the following:

🌿

Good air: 400 to 800 ppm

No alarm; display shows “good air”. The alarm relay is energised.

💨

Please ventilate: 800 to 1,000 ppm

No alarm, but the display indicates the need to ventilate via a text message. The alarm relay remains energised.

🟠

Loaded air, pre-alarm: 1,000 to 2,500 ppm

Discreet double beep for a short time with a longer pause; the alarm LED flashes. The alarm relay remains energised.

🔴

Heavily loaded, alarm: 2,500 to 5,000 ppm

Loud alarm tone and flashing LED; the alarm relay drops out. This is the highest alarm threshold (half MAK).

Behaviour in the event of an alarm

  1. Ventilate the room and open all doors and windows. If necessary, inform other people and ask them to leave the room.
  2. Stay calm; there is absolutely no reason to panic. Even CO₂ concentrations near 5,000 ppm are not life-threatening. 5,000 ppm for a long time corresponded to the MAK (maximum workplace concentration for 8 hours).
  3. Stop all use of combustion appliances and ensure fresh air.
  4. If necessary, mute the alarm tone with the RESET button. It remains muted until the system falls back into “pre-alarm” mode as the CO₂ concentration decreases.

Test regularly

For your own safety the manufacturer recommends regularly checking the acoustic alarm transmitter for proper function with the test button. Both relays Re1 and Re2 also drop out during this test.

The device monitors itself

A 32-bit microcontroller continuously monitors the system at around 300 points in hardware and software. Several temperatures, voltages and currents are measured and compensated, results for internal long-term tests are stored, calculated against each other and some of them displayed on the screen. In addition the system performs regular tests on the sensor element. If the result is “good”, you notice nothing. If it is “not good”, the system restarts up to three times, repeats the measurements and then decides whether to issue a fault message.

1

Fault is displayed

In every case the fault relay Re2 drops out so that the building management system or home automation is informed. In addition the yellow LED flashes or lights and a short beep sounds every 10 seconds.

2

Retrieve error number

Press the Service button until the display shows the type of fault. The term “error” and a number appear. Quote this number to the Technical Support of Elektrotechnik Schabus, who will find a solution together with you.

3

Interpret the yellow LED correctly

Only a few faults affect the measurement and prevent alarming. Others merely indicate adverse ambient conditions with accelerated ageing or mains voltage fluctuations. The blink rhythms come directly from the microcontroller. If the yellow LED only lights continuously, the controller itself has a problem. This can only be remedied at the factory in Stephanskirchen; please contact the manufacturer.

4

Clear the fault

Press the Test/Reset button so that the fault relay Re2 is energised again. If the fault persists, Re2 remains energised and only drops out again on a new fault. Often a fault clears itself. Alternatively, disconnect the device from the mains, let it cool for about 15 minutes and put it back into operation; ensure sufficient fresh air during this time. If the fault message remains, take the device out of service and have it checked by a qualified specialist.

Maintenance-free, but not care-free

The GX-D250 operates maintenance-free. Only remove dust from it from time to time using dry cloths. Please do not vacuum the device: through the small slots and openings in the housing very high wind speeds could arise inside that would permanently impair the internal temperature sensors through excessive cooling or transmit incorrect values to the processor. Consequences would be an early defect, a severely reduced service life or permanently incorrect measured values.

The external CO₂ sensor should be regularly exposed to fresh air during operation. The lowest CO₂ value measured continuously for at least 20 minutes within each 7 uninterrupted operating days is interpreted as the 400 ppm point, stored and adopted as the new calibration value (zero-point adjustment) for subsequent measurements. If the device is used as intended as a reminder for regular ventilation, it is entirely sufficient to thoroughly ventilate the monitored room once a day and on 2 out of 7 days of a week. The manufacturer also recommends regularly testing infrared sensors and recalibrating them for about 30 minutes in fresh air weekly.

Avoid the influence of moisture (splash or rain water), dust and direct sunlight on the device. Clean it only with a dry linen cloth, which may be slightly dampened in case of heavy soiling. Do not use solvent-based cleaning agents.

Note for maintenance companies: The manufacturer recommends entering all information with date and time in a list at every visit. This allows conclusions to be drawn after some time about the operational safety of the system and about possible manipulations or malfunctions.

What the display shows

After each press of the SERVICE button you move to the next display until the main display appears again. If you remain on a display, the device automatically switches back to the main display after a while, or if you press the SERVICE button a little longer.

1

Main display

Current CO₂ concentration in ppm and the evaluation of the air, e.g. “good air”.

2

Product Type

Shows the type designation of the device.

3

Software Version

Shows the installed software version.

4

On Time

Shows the time since switch-on.

5

Last Error

Shows the last error code that occurred.

+

Further displays

Depending on the software there are further permanently stored displays that are mainly needed in service cases. Some values are already present because every single device is extensively tested before it leaves the factory in Stephanskirchen.

Manufacturer’s notes

  • Read the operating instructions carefully before installation and commissioning and keep them
  • Installation must be carried out by a qualified specialist; the five safety rules must be observed
  • Packaging material is not a toy and must be kept away from children
  • Intended for residential rooms and rooms with residential-like use
  • Intended for residential buildings, sales areas and rooms of small businesses such as workshops and service centres, each connected to the public low-voltage network
  • Not suitable for monitoring CO₂ from technical systems under pressure or for dry-ice processing
  • Do not use in potentially explosive atmospheres; the device is not approved for other uses
  • The measuring cell, evaluation and software were tested by TÜV Süd as part of the development of a CO₂ sensor; safety and stability were certified for the system. The complete warning device GX-D250 was not tested by TÜV
  • The declaration of conformity is available for download on the manufacturer’s website

Warranty, guarantee, return and disposal

The GX-D250 is covered by the statutory warranty of at least 2 years in the EU. The manufacturer Elektrotechnik Schabus additionally offers a 5-year guarantee that can be registered online. Repair and spare parts are available directly from the manufacturer, even beyond the statutory warranty. Personal specialist advice is available without a call centre directly from the manufacturer. In the event of a warranty claim, the device is sent in sufficiently packed with a description of the fault, proof of purchase as well as address and delivery address. The device must have been used in accordance with the operating instructions.

Return: In the event of a defect, first contact the manufacturer and state the complete address as well as the reason for return. Within Germany the manufacturer arranges free collection of the parcel. Unpaid parcels will not be accepted, and unjustified returns that do not constitute a complaint will be charged subsequently.

The GX-D250 does not belong in household waste. The crossed-out wheeled bin symbol on the product reminds you to use the take-back systems for waste electrical and electronic equipment (WEEE No. DE91394868). Further information is available from your local waste advice centre or from the manufacturer.

Areas of application

  • Classrooms and schools
  • Seminar rooms and further education
  • Offices and open-plan offices
  • Meeting and conference rooms
  • Medical practices and waiting rooms
  • Public facilities
  • Co-working spaces
  • Living rooms and home office

The Schabus Professional CO₂ Detector GX-D250: Because good air knows no compromises.

Frequently asked questions

What is the GX-D250 intended for?

It permanently monitors the CO₂ concentration in residential and office spaces and in rooms with residential-like use, reminds you to ventilate and can control ventilation via relays. It is not suitable for CO₂ from technical systems under pressure or for dry-ice processing.

What is the difference from the socket devices GX-D1 and GX-D2?

The GX-D250 is a permanently installed wall device with plain-text display, pre-alarm from 1,000 ppm, two potential-free changeover relays and an external sensor. It can therefore switch ventilation technology and report faults to the building management system. Installation is carried out by a specialist.

When does the GX-D250 warn?

From 800 ppm the display indicates the need to ventilate. Between 1,000 and 2,500 ppm the pre-alarm with discreet double beep is active. From 2,500 ppm the main alarm triggers with a loud tone, flashing LED and dropping alarm relay.

Is 2,500 ppm already dangerous?

No. 2,500 ppm corresponds to roughly half the MAK. Even CO₂ concentrations near 5,000 ppm are not life-threatening; 5,000 ppm for a long time corresponded to the MAK. The alarm primarily reminds you to thoroughly ventilate the room.

What do the two relays switch?

The alarm relay Re1 switches on alarm and can, for example, activate forced ventilation, control ventilation flaps or close solenoid shut-off valves. The fault relay Re2 switches on a detected fault and reports it, for example, to the building management system. Both are potential-free changeover contacts. In normal operation they are energised; in the event of alarm or fault they drop out.

Where do I place the control unit and the sensor?

The control unit is mounted at medium height on the wall so that the display is easy to read while standing. The sensor can be mounted independently at nose height in the occupancy area. Mounted lower it reacts more sensitively; mounted higher more tolerantly.

Can I extend the sensor cable?

Yes, according to the manufacturer the sensor cable can be extended up to 50 m.

How long does it take until it is ready for operation?

After applying the voltage a start phase of 5 minutes runs with function tests and sensor pre-heating. The display shows “CO₂: Wait / Prepairing”. When the green LED then lights alone, the system is ready for operation. Ventilate thoroughly beforehand and move away from the sensor during the start phase.

How do I switch off the alarm tone?

With the RESET button. The tone remains muted until the system falls back into pre-alarm as the CO₂ concentration decreases. Ventilate thoroughly in the meantime.

How do I test the function?

With the test button you regularly check the acoustic alarm transmitter for function. Both relays Re1 and Re2 also drop out; bear this in mind with connected devices.

The yellow LED lights or flashes. What should I do?

The device has detected a fault; the fault relay has dropped out and it beeps briefly every 10 seconds. Press the Service button until the display shows “error” and a number, and quote this number to Technical Support. With the Test/Reset button the fault relay can be reset. If the message remains, take the device out of service and have it checked by a specialist.

Do I need to maintain the device?

No, the GX-D250 operates maintenance-free. Only remove dust from time to time with dry cloths and do not vacuum the device. The sensor should regularly receive fresh air: thoroughly ventilating once a day and on 2 out of 7 days per week is sufficient.

How long does the sensor last?

The manufacturer states a service life of about 8 to 10 years for 90 % of the sensors. This is based on manufacturer experience, is not a guarantee and serves for comparison. Under ideal ambient conditions the service life can be longer.

How long is the guarantee valid?

The statutory warranty of at least 2 years in the EU applies. In addition, Schabus offers a 5-year guarantee that can be registered online.

Questions about the Professional CO₂ Detector GX-D250?

Our support team in Germany advises you free of charge on selection, installation and configuration.

Videos
YouTube
Datasheets
Datasheet 1

Oops! Your browser doesn't support PDFs!

Datasheet 1 (2.43 MB)
Datasheet 2

Oops! Your browser doesn't support PDFs!

Datasheet 2 (1.05 MB)

Professional CO₂ Alarm GX-D250 – For Residential and Office Areas

The GX-D250 is a professional CO₂ alarm for residential and office environments. It reliably detects elevated CO₂ concentrations using an external NDIR infrared sensor and optical absorption technology. With precise indication, potential-free relay contacts, and simple installation, it is ideally suited for monitoring indoor air quality.

Technical Data

  • Operating voltage: 100–240 V AC / 50–60 Hz
  • Power consumption: max. 10 VA (typ. 2 VA depending on operating state)
  • Degree of protection: IP 54 (control unit), IP 20 (sensor)
  • Dimensions: Control unit 80 × 160 × 55 mm, sensor 52 × 27 × 29 mm (H×W×D)
  • Sensor lifetime: approx. 8–10 years (90% of sensors, depending on environmental conditions)*
  • Relay contacts: 2 potential-free changeover contacts (NC/NO)
    Re1 “Alarm”: 250 V AC / 5 A
    Re2 “Fault”: 60 V DC / 5 A
  • Cable: 2.5 m, 2×0.14 mm², white
    Sensor cable: 3×0.14 mm², 6 m, white, Ø 3.5 mm, extendable up to 50 m
  • Humidity: 10–90% rH, non-condensing

Sensor & Measurement

  • Sensor type: External NDIR infrared, optical CO₂ absorption
  • Sensor output: brown 9–30 VDC, green GND, white PWM
  • Response time: approx. 90 seconds
  • Sensor operating range: 0°C … 50°C / 10–90% rH (non-condensing)

Alarm

  • Pre-alarm: >1000 ppm CO₂
  • Main alarm: >2500 ppm CO₂
  • Reference value: 800 ppm CO₂
  • Sound pressure level: 85 dB(A) @ 1 m (control unit), 90 dB @ 10 cm (local)

Environmental Conditions

  • Control unit operating range: -15°C … +45°C / 10–90% rH (non-condensing)
  • Sensor operating range: 0°C … 50°C / 10–90% rH (non-condensing)
  • Storage temperature: -20°C … +70°C

*Note: Lifetime specifications are based on manufacturer experience and are for comparison purposes. Infrared sensors should be tested regularly and recalibrated weekly for about 30 minutes in fresh air. Under ideal environmental conditions, the service life may be longer.

Manufacturer information:

Electrical engineering Schabus GmbH & Co. KG

Baierbacher Straße 150

83071 Stephanskirchen
Germany

Telephone: +49 80 36 / 674 979 – 0

Email: info@elektrotechnik-schabus.de

Responsible person:

Didactum® Security GmbH

Im Mühlenfeld 4

48163 Münster
Deutschland

Fon: (+49) 250 19 71 63 54 / (+49) 171 33 11 577

Email: info@didactum-security.de

Questions?

You have questions about Schabus products?

You would like a quote?

Contact us