Skip to main content Skip to search Skip to main navigation

Gas Alarm GX-C1pro Plug-in Device 230V

The Plug-In CO Alarm: Early Warning of Carbon Monoxide, with TÜV-Tested Sensor to DIN EN 50291, No Installation Effort

The Schabus CO alarm GX-C1pro is a plug-in device (230 V) for the early detection of dangerous carbon monoxide concentrations in living spaces. It is simply plugged into a socket at mid-room height and is ready for operation after about 5 minutes of initialisation time.

Carbon monoxide (CO) is colourless, odourless and tasteless, arises from incomplete combustion and can already be life-threatening in low concentrations. The GX-C1pro detects CO with its electrochemical sensor and alarms in accordance with DIN EN 50291, loudly and acoustically with a piezo buzzer as well as optically with a red flashing LED. It already warns at a gas concentration that is far below the life-threatening value.

The device monitors carbon monoxide at combustion sites in apartments, houses, shops, small businesses, cafés and low-dust workshops, for example at gas boilers, gas heating systems, gas cookers, gas ovens, but also at oil heating systems and open fires. It is suitable for normal household use.

⚠️

Important note: The GX-C1pro does not replace the proper installation, use and maintenance of fuel-burning appliances including the associated ventilation and flue systems. It must not be used in potentially explosive atmospheres and only indoors.

💡

Good to know: The device tests the sensor and electronics when plugged in and then every 24 hours itself. A test with gas is therefore not necessary. You carry out the functional test of LEDs and alarm tone yourself using the test button; the manufacturer recommends this every six months.

Plug In, Monitor, Be Warned

The GX-C1pro combines a tested sensor with clear optical and acoustic alarming and automatic self-monitoring.

🔌

Simply Plug In

230 V plug-in device, installed in seconds, no installation effort.

🔬

Electrochemical Sensor

Maintenance-free sensor with high long-term stability and low drift. It detects CO from all gas-operated systems.

✅

TÜV-Tested to DIN EN 50291

The measuring cell has a full TÜV test to DIN EN 50291. Sensor technology, calibration, evaluation and software have been tested and certified by TÜV Süd.

🔔

Dual Alarming

Loud acoustic alarm with piezo buzzer and red flashing LED. The alarm characteristic complies with the requirements of DIN EN 50291.

⏳

Standard-Compliant Alarm Delay

Depending on the concentration, a pre-alarm first starts via the LED. The buzzer only sounds when the elevated concentration is present for longer than the delay time.

🔁

Automatic Self-Test

Sensor and electronics test themselves when plugged in and every 24 hours. In the event of a fault the device restarts itself.

🔘

Test Button

A short press checks all three LEDs and the alarm generator.

🛁

Also in Damp Rooms

Also usable in bathrooms and other damp rooms as long as the moisture does not condense.

🏭

For Years of Continuous Operation

Designed for continuous operation at the socket.

What's in the Box

The GX-C1pro is ready for immediate use. The device has no options and no additional variants.

  • CO alarm GX-C1pro
  • Operating instructions

Mounting material is not required because the device is simply plugged into the socket.

How the GX-C1pro Is Constructed

Plug housing, sensor, electronics and alarm generator are combined in one device. It contains no parts that you need to maintain.

1

Plug Housing with Mains Plug

The light plastic housing carries the mains plug for the 230 V socket on the rear. The device hangs directly in the socket; cable and power supply unit are not required.

2

Ventilation Slots on the Housing

Via the slots in the housing the room air reaches the sensor. Therefore the device must not be operated behind curtains or in cupboards.

3

Electrochemical Sensor

Inside is the sensor that detects carbon monoxide. It is maintenance-free but is regularly checked automatically for function. On the underside of the housing is the date (month/year) of the next sensor test.

4

Display Panel with Three LEDs

On the device front three LEDs show the status: green “Operate” (operation), yellow “Error” (fault) and red “Alarm”.

5

Test Button

Next to the LEDs is the test button. With a short press you check the three LEDs and the alarm generator.

6

Piezo Buzzer

The integrated alarm generator emits the loud alarm tone. In the event of a fault it also reports with a short information tone.

How the GX-C1pro Warns

The alarm operates in several stages, from normal operation via pre-alarm to alarm.

🟢

Normal Operation

The green LED “Operate” lights. The device monitors the room air and tests itself every 24 hours.

🟠

Pre-Alarm

As soon as the GX-C1pro detects carbon monoxide, the concentration-dependent delay time starts. The “Alarm” LED flashes red; the buzzer remains silent.

🔴

Alarm

If the elevated concentration is present for longer than the delay time, the acoustic alarm sounds and the “Alarm” LED continues to flash.

🟡

Sensor Fault

If the device detects a fault, the yellow LED “Error” flashes or lights and the buzzer emits a short information tone every 30 seconds. This is not an alarm.

Position Correctly, Plug In, Test

The device must be correctly positioned depending on the gas source so that it functions properly.

Placement

  1. Choose the room in which the occupants spend the longest time, as close as possible to a sleeping place.
  2. Choose a socket that is as far as possible from a cooking area, at mid-room height or at nose height of the main occupancy position.
  3. Maintain a minimum distance of 30 cm from corners, edges, ceilings, floors and other devices as well as a distance of 1 to 3 metres from combustion sites.

These Locations Are Unsuitable

  • Places that could prevent the alarm from being triggered in the event of a gas escape, for example behind curtains or in cupboards
  • Directly above a cooker or a combustion site or above a washbasin
  • Next to a door, windows, ventilation, fan, air conditioning and similar
  • Areas in which dust, moisture or dirt can put the sensor out of operation
  • In the immediate vicinity of the cooker
  • Areas outside the intended temperatures or humidities, also with condensing moisture
  • Potentially explosive atmospheres

Commissioning

  1. Plug the GX-C1pro into a 230 V socket. The green LED “Operate” lights up and the alarm tone sounds once briefly.
  2. Wait for the initialisation phase of about 5 minutes. After that the device is ready for operation.
  3. Press the test button briefly. This verifies the function of all three LEDs and the alarm generator.
  4. Repeat the test at regular intervals; every 6 months is recommended.

What You Should Do in the Event of an Alarm

Act calmly and consistently. With carbon monoxide the safety of all persons in the house is paramount.

  • Do not unplug the warning device and remain calm
  • Do not put any further electrical devices into operation
  • Do not light any open flame and do not extinguish any open fire
  • Immediately open windows and doors and thoroughly ventilate the room or the house
  • Inform other persons in the house. All persons must leave the house
  • Check the room or the house for possible sources of fire, because carbon monoxide also arises from the smoke of fires
  • Eliminate the cause of the gas escape. In case of doubt contact your energy supply specialist
  • In the event of a persistent or repeated alarm contact the energy supply specialist or the fire brigade

Manufacturer’s Notes

  • Read the operating instructions thoroughly before installation and first commissioning and keep them
  • Use only indoors
  • Intended for residential buildings, sales areas with residential-like use and rooms of small businesses such as workshops and service centres with connection to the public low-voltage network
  • The device is not approved for any other use
  • Do not use in potentially explosive atmospheres
  • The device does not replace the proper installation, use and maintenance of fuel-burning appliances and their ventilation and flue systems
  • The operating instructions state installation by a qualified specialist
  • Packaging material is not a children’s toy and does not belong in children’s hands
  • The manufacturer is not liable for damage or losses arising from the fact that no alarm signal is given despite a gas escape
  • Repairs and maintenance may only be carried out by the manufacturer or authorised specialist personnel

What the GX-C1pro Does Not Do

  • It detects carbon monoxide. It does not specifically report other gases
  • Due to its design the electrochemical sensor also responds to other gaseous media such as hydrogen or various sulphur compounds
  • Aerosols (propellant gas in sprays for hair, disinfection and similar), strong tobacco smoke, for example from a smoking card game, and cooking fumes can lead to a false alarm
  • It does not replace professional maintenance of fireplaces, ventilation and flue systems
  • It is not intended for potentially explosive atmospheres and not for outdoor use
  • You cannot test the sensor and electronics yourself. This is handled by the software in operation every 24 hours
  • The sensor has a limited service life that depends on the environment. The date of the next sensor test is on the underside of the housing

Clean, Check, Find Faults

Check and Clean

  • Carry out the test button every six months
  • Clean the sensor regularly by blowing the dust off the device
  • Keep moisture away from the device
  • Clean the device only with a dry linen cloth; in case of heavy soiling it may be slightly dampened
  • Do not use solvent-containing cleaning agents
  • Avoid moisture (splash or rain water), dust and direct sunlight
  • Keep an eye on the date of the next sensor test on the underside of the housing and send the device in good time to the manufacturer for the factory test

Troubleshooting

🟡

Yellow LED “Error” Flashes or Lights?

The device has detected a sensor fault; the buzzer emits a short information tone every 30 seconds. This is not an alarm. Contact the manufacturer.

❓

Unexpected Alarm?

Check whether aerosols, strong tobacco smoke or cooking fumes could be the cause. In the event of an alarm nevertheless first ventilate and behave as described in the section “Behaviour in the Event of an Alarm”.

⚡

No Response When Plugging In?

Check whether the socket is live. When plugging in the green LED must light and the alarm tone must sound briefly.

If the fault persists, contact Schabus Support.

Matching Accessories, Available Separately

The GX-C1pro itself has no options. Matching this the manufacturer offers an anti-theft device.

🔒

Anti-Theft Device for Plug-In Devices

Protects plug-in devices and intermediate plugs against unauthorised removal. Ideal for public areas, basements, garages or commercial installations.

In Case of Service and Return

  1. Get in touch if the device is defective and state your complete address as well as the reason for return.
  2. Within Germany the manufacturer will send you a free return label by e-mail.
  3. Pack the device adequately. Enclose a fault description, proof of purchase as well as your address and delivery address (name, telephone number, street, house number, postcode, city, country).

The manufacturer cannot accept unfree parcels. Unauthorised returns that do not constitute a complaint will be charged subsequently.

Warranty, Guarantee and Disposal

The GX-C1pro is covered by the statutory warranty of at least 2 years in the EU. In the event of material defects and quality deficiencies the manufacturer repairs or replaces the device free of charge provided it has been used in accordance with the operating instructions. In addition, Elektrotechnik Schabus offers a 5-year guarantee that can be registered online. Repair and spare parts are available directly from the manufacturer, even beyond the statutory warranty.

The device bears the CE marking. The declaration of conformity can be found on the manufacturer’s website.

The GX-C1pro does not belong in household waste. The crossed-out waste bin symbol on the product reminds you to use the take-back systems so that the materials can be reused in an environmentally friendly manner at the end of the service life (WEEE Reg. No. DE91394868). Further information is available from the waste advice centre of your city or from the manufacturer.

Why the GX-C1pro Is Suitable

Ready for Immediate Use

Plug in, wait about 5 minutes, done.

Tested Safety

TÜV-tested sensor to DIN EN 50291, software and calibration certified by TÜV Süd.

Dual Warning

Loud piezo buzzer and red flashing LED.

Monitors Itself

Automatic self-test every 24 hours, no test with gas necessary.

Versatile Use

For apartments, houses, shops, cafés and low-dust workshops, also in the bathroom.

From the Manufacturer

Personal expert advice, 5-year guarantee registrable, repair and spare parts directly from the manufacturer.

Application Areas

  • Apartments with gas boiler
  • Houses with heating boiler, including gas and oil heating systems
  • Rooms with fireplace or stove
  • Kitchens with gas appliances and gas cooker
  • Rooms with open fires
  • Shops and cafés
  • Small businesses and low-dust workshops
  • Bathrooms and other damp rooms without condensation

The Schabus CO alarm GX-C1pro: CO detected, danger averted.

Frequently Asked Questions

How does the CO alarm GX-C1pro work?

An electrochemical sensor detects carbon monoxide in the room air. As soon as CO is detected, a concentration-dependent delay time starts and the red “Alarm” LED flashes. If the elevated concentration is present for longer than the delay time, the loud alarm buzzer additionally sounds.

How do I install the alarm?

Plug the GX-C1pro into a 230 V socket. The green LED “Operate” lights up and the alarm tone sounds once briefly. After an initialisation phase of about 5 minutes the device is ready for operation. Choose a suitable location at mid-room height.

Where should I place the alarm?

In the room in which the occupants spend the longest time, close to a sleeping place, as far as possible from a cooking area, at mid-room height or at nose height of the main occupancy position. Maintain a minimum distance of 30 cm from corners, edges, ceilings, floors and other devices as well as 1 to 3 metres distance from combustion sites.

Where must I not operate the alarm?

Not behind curtains or in cupboards, not directly above a cooker or a combustion site or above a washbasin, not next to a door, windows, ventilation, fan or air conditioning, not in areas with dust, dirt or condensing moisture and not in potentially explosive atmospheres.

Can I use the alarm in the bathroom?

Yes, use in the bathroom and other damp rooms is also possible as long as the moisture does not condense. However, do not mount it above a washbasin and keep splash and rain water away.

What do the three LEDs mean?

The green LED “Operate” indicates operation. The yellow LED “Error” flashes or lights when a fault has been detected. The red LED “Alarm” flashes as soon as carbon monoxide is detected, first in the pre-alarm without tone, later together with the acoustic alarm.

What is the difference between pre-alarm and alarm?

In the pre-alarm the device has detected carbon monoxide and the concentration-dependent delay time is running. The red LED flashes; the buzzer is silent. Only when the elevated concentration is present for longer than the delay time does the device trigger the acoustic alarm.

What to do in the event of an alarm?

Do not unplug the warning device and remain calm. Do not put any further electrical devices into operation, do not light any open flame and do not extinguish any open fire. Immediately open windows and doors and thoroughly ventilate, inform other persons and leave the house. Check the room for sources of fire and eliminate the cause; in case of doubt contact the energy supply specialist. In the event of a persistent or repeated alarm contact the specialist or the fire brigade.

Can there be false alarms?

Due to its design the electrochemical sensor also responds to other gaseous media such as hydrogen or various sulphur compounds. Aerosols, strong tobacco smoke and cooking fumes can also lead to a false alarm. Therefore observe the recommended location, in particular the distance from the cooking area.

How do I test the device?

With a short press of the test button you check the function of all three LEDs and the alarm generator. The manufacturer recommends carrying out the test every six months. You cannot test the sensor and electronics yourself; this task is handled by intelligent software in operation every 24 hours.

What happens if the self-test finds a fault?

The device first carries out a restart itself. Only if the fault occurs again does the yellow LED “Error” flash or light and the buzzer emit a short information tone every 30 seconds. This is not an alarm. In this case contact the manufacturer.

What does the date on the underside mean?

On the underside of the housing is the date (month/year) for the next sensor test. Send the device to the manufacturer for the factory test.

How do I clean the alarm?

Remove dust regularly by blowing and keep moisture away from the device. For cleaning a dry linen cloth is sufficient; in case of heavy soiling it may be slightly dampened. Do not use solvent-containing cleaning agents.

Does the alarm replace the maintenance of my heating or gas boiler?

No. The device does not replace the proper installation, use and maintenance of fuel-burning appliances including the associated ventilation and flue systems.

Are there options or additional variants?

No. The GX-C1pro has no options. As separate accessories an anti-theft device for plug-in devices is available.

How long is the guarantee valid?

The statutory warranty of at least 2 years in the EU applies. In addition, the manufacturer Schabus offers a 5-year guarantee that can be registered online.

Questions about the CO alarm GX-C1pro?

Our support team in Germany advises you free of charge on selection, installation and configuration.

Videos
Video 1
Datasheets
Datasheet 1

Oops! Your browser doesn't support PDFs!

Datasheet 1 (1.81 MB)

GX-C1pro CO Alarm: Plug-in Early Warning without Installation – TÜV Certified, Maintenance-Free

Carbon monoxide knows no floor level – the GX-C1pro from Elektrotechnik Schabus GmbH & Co. KG makes it simple: just plug it in, wait 5 minutes, and you are protected.

The internal, TÜV-certified electrochemical sensor (DIN EN 50291) detects CO from gas boilers, fireplaces, oil heaters or gas stoves – with minimal cross-sensitivity. When the limit is exceeded, a loud piezo alarm sounds and a red LED flashes – a dual warning system.

Automatic self-test every 24 hours, manual test button, no gas calibration required. Powered directly from 230 V – no batteries, no replacements. Suitable for humid environments (such as bathrooms, provided no condensation forms). Robust, display-free, and made in Germany – the GX-C1pro is your invisible life insurance in any room where combustion occurs.

The GX-C1pro’s technology is compliant with standards and designed for daily use: a highly selective sensor fully TÜV-tested for cell, electronics, and software performance. Responds in stages according to DIN EN 50291 – immediate at high concentrations, delayed at low levels, eliminating false alarms. Flexible installation height (1–1.8 m), as CO distributes evenly throughout the air.

The self-test checks the sensor, electronics, and alarm every day. Operates in any 230 V socket – ideal for rented flats, older buildings, cafés, or workshops. The GX-C1pro is not just a detector, but an active protection system – simple, reliable, and maintenance-free.

The GX-C1pro is more than just a device – it is plug-in safety. Whether for a gas boiler in the utility room, a fireplace in the living room, a gas stove in the kitchen, or an oil heater in the basement: a blocked flue, leaking burner, or unattended pot – the GX-C1pro provides an early warning. Tenants, homeowners, and business owners appreciate its instant setup and automatic self-test. No drilling, no electrician, simply plug it in. Its robust housing, calibrated sensor, and German craftsmanship make the GX-C1pro a long-lasting safety companion. Proof that protection can be simple. With the GX-C1pro, you invest in peace – the peace that comes when a small device eliminates major risks.

The GX-C1pro at a Glance:

  • TÜV DIN EN 50291: Fully tested cell and software – standard-compliant, immune to false alarms.
  • Plug & Play: 230 V socket – installed in seconds.
  • Loud alarm: Piezo buzzer and red flashing LED – impossible to ignore.
  • 24 h self-test: Automatic + test button – always operational.
  • Moisture-resistant: Suitable for bathrooms and basements – as long as no condensation.
  • Flexible mounting position: 1–1.8 m height – CO disperses evenly in air.
  • Low cross-sensitivity: No false alarms from household chemicals.
  • Made in Germany: Exceptional quality, durability, and support from Schabus.

Applications: Where the GX-C1pro Provides Reliable Protection

The GX-C1pro ensures CO safety in all dry or slightly humid indoor environments where combustion appliances are used:

  • Boiler rooms: Gas or oil boilers – warns of exhaust backflow.
  • Living rooms with fireplaces: Plug in at 1.5 m – protection against incomplete combustion.
  • Kitchens with gas stoves: Convenient near socket – safe cooking.
  • Bathrooms: Moisture-tolerant – usable with gas water heaters.
  • Rented apartments and older buildings: No approval required – instant security.
  • Cafés and small businesses: Additional safety – works wherever there’s a plug.
  • Workshops (low dust): Complements safety systems – protects employees.

With the GX-C1pro, CO safety begins at the socket. It’s the simplest and fastest solution for anyone using gas or oil – without compromising safety. The automatic self-test, loud alarm, and German quality make it an essential part of every household.

Scope of Delivery

  • Gas Alarm GX-C1pro
  • User manual

Safety Instructions

  • Before installation or use, read the operating instructions carefully.
  • Packaging material is not a toy. Keep out of reach of children.
  • Installation must be performed by qualified personnel.

Intended Use

  • The GAS ALARM GX-C1pro with electrochemical sensor is a carbon monoxide (CO) detector that triggers at concentrations far below life-threatening levels.
  • This monitoring system is intentionally configured with high sensitivity.
  • The device is suitable for normal household use and must not be used in explosive environments.
  • Any use other than that described is not permitted.
  • The device does not replace proper installation, operation, or maintenance of fuel-burning appliances and their ventilation or exhaust systems.

Manufacturer information:

Electrical engineering Schabus GmbH & Co. KG

Baierbacher Straße 150

83071 Stephanskirchen
Germany

Telephone: +49 80 36 / 674 979 – 0

Email: info@elektrotechnik-schabus.de

Responsible person:

Didactum® Security GmbH

Im Mühlenfeld 4

48163 Münster
Deutschland

Fon: (+49) 250 19 71 63 54 / (+49) 171 33 11 577

Email: info@didactum-security.de

Questions?

You have questions about Schabus products?

You would like a quote?

Contact us