€116.81
The refrigerant warning device with external sensor: place the sensor directly at the potential leakage source, for R32 on heat pumps and air-conditioning systems
The Schabus GX-K2 is a plug-in refrigerant warning device with an external sensor for detecting fluorinated refrigerants (HFCs/HFCs). It monitors the ambient air for escaping refrigerants and coolants and already warns at low concentrations. The target gas is R-32; the sensor also responds to many other refrigerants.
The special feature of the GX-K2 is the sensor head: it is connected to the plug-in unit via a cable and can be mounted where it measures best – close to the potential leakage source and matched to the properties of the refrigerant – without structural measures. In the event of a leak, the GX-K2 warns optically with a red flashing LED and, if the concentration continues to rise, additionally acoustically with a loud alarm tone. After the warm-up phase of approximately 3 to 5 minutes it is ready for operation.
Important note: Both the warning device and the external sensor are intended only for dry indoor areas. The GX-K2 is not an outdoor detector and must not be operated in locations with rain, splash water or condensation, or in potentially explosive atmospheres. Mounting directly next to the outdoor unit of a heat pump is therefore not intended. The sensor cable must not be extended or modified. The warning device does not replace the proper installation, maintenance and servicing of the monitored system.
Good to know: Fluorinated refrigerants are climate-damaging, some are flammable and some are harmful to health. Their use is regulated by the EU F-Gas Regulation. The trigger concentration depends on the type of gas; there is therefore no uniform value for different refrigerants. An alarm also does not indicate which gas triggered the warning.
Sensor where refrigerant can escape
External sensor
The sensor head can be positioned independently of the socket at the suitable measuring point, without structural measures.
Simply plug in
230 V plug-in device, ready for immediate use. Mounting material for the sensor is included.
R-32 and many other refrigerants
Target gas R-32, plus R-410A, R-404A, R-407C, R-454B, R-1234yf, R-1234ze, R-290 (propane) and R-22.
Optical pre-alarm
When the alarm threshold is reached, the red LED flashes.
Acoustic main alarm
If the concentration continues to rise, a loud alarm tone also sounds from the piezo buzzer.
Three status LEDs
Operation, fault and alarm are visible at a glance.
TEST button
Checks LEDs and sounder. In the event of an alarm it mutes the tone.
Ready for operation after 3 to 5 minutes
During the warm-up phase the green LED flashes; afterwards it lights continuously.
Fault and cable-break indication
In the event of a fault the yellow LED flashes and a signal tone sounds every 30 seconds.
Sensor replaceable by the user
The external sensor can be replaced by the user. Coordinate sensor replacement and factory inspection with Schabus Support.
Which refrigerants the GX-K2 detects
The sensor detects numerous common refrigerants and also responds to other gases.
Refrigerants
- R-32 (target gas)
- R-410A, R-404A, R-407C, R-454B
- R-1234yf, R-1234ze
- R-290 (propane)
- R-22
- Other fluorinated refrigerants (HFCs/HFCs)
Cross-sensitivities
- Methane, butane and propane
- Ethanol and hydrogen
- Other hydrocarbons
- Certain sprays or vapours
Sensitivity and therefore the trigger concentration differ depending on the type of gas. The GX-K2 does not detect carbon monoxide and does not replace a CO detector.
What is included in the box
The GX-K2 is ready for immediate use. The device has no options and no additional variants.
- Refrigerant warning device GX-K2 (plug-in unit)
- External sensor with 2.5 m sensor cable, not extendable
- Mounting material for the external sensor (screw and plug)
- Operating instructions
How the GX-K2 is constructed
The system consists of two parts: the plug-in unit in the socket and the external sensor, which is connected via the cable. The plug-in unit contains no parts that you need to maintain or repair and must not be opened.
Plug-in unit with Schuko plug
The main unit is plugged directly into a 230 V socket with its plug on the rear, which also supplies the system with power. It contains the electronics, the LEDs, the TEST button and the sounder.
Acoustic sounder
The piezo buzzer is located in the plug-in unit; the tone passes through the large slots in the housing to the outside. It emits a short tone when plugged in, a loud alarm tone during the main alarm and a signal tone every 30 seconds in the event of a fault.
Status LEDs
Green indicates the warm-up phase and operation, yellow a fault, red pre-alarm and main alarm.
TEST button
It checks the LED indicators and the acoustic sounder. The sensor is not checked by this. In the event of an alarm it mutes the alarm tone; the red LED continues to flash as long as gas is detected.
Sensor cable
The cable connects the plug-in unit and the external sensor. It is 2.5 m long and must not be extended or modified. Take the length into account when choosing the socket and sensor position. In the event of a fault, check the cable and the plug connection.
External sensor
The sensor head measures the air where you mount it. It is fixed with the supplied screw and plug, as close as possible to the potential leakage source.
Air inlet slots on the sensor
Room air reaches the sensor element through the slots in the sensor housing. Keep them clear and dry. The date (month/year) on the sensor indicates the next inspection date.
Correct placement and commissioning
With the GX-K2 the position of the external sensor is decisive. The height depends on the refrigerant used.
Where the sensor belongs
- General: Mount the sensor close to the potential leakage source and matched to the properties of the refrigerant
- Gases heavier than air (for example R-290/propane sinks to the floor, spreads in a similar way to water and collects in depressions): sensor 15 to 30 cm above the floor
- Gases lighter than air: sensor 15 to 30 cm below the ceiling and above the highest door or window opening in the room
- Distance to the monitored system: maximum 4 m
- Sensor cable: It is 2.5 m long and not extendable. Choose the socket and sensor position accordingly
- Check the refrigerant: Obtain information from the manufacturer of your refrigeration or air-conditioning system about the refrigerant used and its properties. The position does not affect the way the device works, but it does affect the measurement results
Where the device must not be operated
- In draughts, next to doors, windows or ventilation openings
- Directly next to a cooker or above a sink
- In locations where dust, dirt or covered sensor openings could impair function
- Outdoors or in locations with rain, splash water or condensation, also not directly next to the outdoor unit of a heat pump
- In potentially explosive atmospheres
Installation and commissioning
- Mount the external sensor close to the potential leakage source with the supplied screw.
- Plug the warning device into a socket. A short alarm tone is heard.
- Wait for the warm-up phase of approximately 3 to 5 minutes. During this time the green LED flashes.
- Only when the green LED lights continuously is the device ready for operation. After an interruption of the power supply the warm-up phase starts again.
- Note: Transport, prolonged storage or moisture can influence the start-up behaviour. In the event of an alarm, first follow the instructions for behaviour in the event of an alarm. A restart may only be carried out once an actual gas leak has been ruled out. In the event of a repeated alarm or uncertainty, contact Schabus Support.
What the LEDs mean and how to test
Green flashing
Warm-up phase, approximately 3 to 5 minutes.
Green steady
Ready for operation; the device monitors the ambient air.
Red flashing
Pre-alarm: A gas or vapour concentration corresponding to the sensitivity of the sensor has been detected.
Red flashing and alarm tone
Main alarm: The concentration continues to rise. Initiate the measures for the event of an alarm.
Yellow flashing
Fault with signal tone every 30 seconds. Possible cause is a sensor, cable or device fault, including a cable break. Check the sensor cable and the plug connection. If the fault persists, contact Support.
All indicators off
Possible cause: socket without voltage or device fault. Check the power supply, but do not carry out any work on the socket. If the indicators remain off, contact Support.
Function test
In the ready-for-operation state, press the TEST button and check whether the LED indicators and the acoustic sounder respond. The TEST button checks the LEDs and buzzer, not the sensor. Check the sensor function on the external sensor with a suitable test medium (R32 test aerosol) and observe the application instructions of the test agent manufacturer. The test gas must diffuse into the air inlet slots of the sensor. Do not gas the sensor directly with lighter gas; strong direct gassing damages the sensor. The manufacturer recommends a monthly function test.
What to do in the event of an alarm or suspected gas leak?
Take the warning seriously and protect people first:
- Warn people: Warn other people and leave the affected area.
- Avoid ignition sources: Do not light any flames, do not operate any electrical switches and do not unplug the warning device from the socket.
- Ventilate if safe to do so: Open doors and windows only if this is possible without endangering yourself.
- Have the cause checked: Have the refrigeration, air-conditioning or heat pump system checked for leaks by a specialised company.
- Return only after clearance: Re-enter the area only when the danger has been eliminated, the cause has been clarified and clearance has been given by emergency services or specialists.
- In the event of acute danger or symptoms, call the emergency number 112 from a safe distance.
With the TEST button you mute the alarm tone. The red LED continues to flash as long as gas is detected. Muting does not eliminate the gas exposure or its cause.
When the sensor triggers without a recognisable leak
Other gases and vapours can also trigger the sensor, for example certain sprays. Nevertheless, always treat a warning initially as a possible gas leak and clarify the cause.
What the warning device does not replace
- The GX-K2 does not detect carbon monoxide and does not replace a CO detector
- It is not explosion-proof and is not approved for potentially explosive atmospheres
- It is not an outdoor detector
- It does not replace the proper installation, maintenance and servicing of the monitored refrigeration, air-conditioning or heat pump system
- An alarm does not indicate which gas caused the warning
- The manufacturer is not liable for damage caused by improper use, modifications to the device or failure to observe the operating instructions
Cleaning, care and sensor service life
Cleaning and care
- Check the sensor openings regularly for dust and dirt and do not cover the device or the sensor
- Clean the housing with a dry, soft cloth, which may be slightly dampened in the case of heavier soiling
- Wipe only the housing and keep the sensor openings dry
- Do not use solvent-based cleaners
- Avoid moisture, splash and rain water as well as direct sunlight
- Do not allow moisture to enter the device or the sensor
- Do not open the plug-in unit; it contains no parts that you need to maintain. Do not extend or modify the sensor cable
Sensor service life and inspection date
The sensor service life is approximately 5 years. The date with month and year on the sensor indicates the next inspection date. The external sensor can be replaced by the user. Coordinate the factory inspection or sensor replacement in good time with Schabus Support.
Manufacturer’s notes
- Read the operating instructions carefully before installation and commissioning and keep them; they form part of the product. Pass the device on to third parties only together with the instructions
- The device is operated with 230 V mains voltage; installation must be carried out by a qualified specialist
- Do not open or modify the device
- Keep the sensor openings clear
- Match the mounting position of the sensor to the refrigerant used
- Packaging material is not a toy and does not belong in children’s hands. Children and persons with reduced physical, sensory or mental capabilities may only use the device under supervision or after instruction in safe use
- Intended for residential buildings and living spaces, commercial and sales rooms as well as rooms of small businesses that are connected to the public low-voltage network
- For other applications, contact Schabus Support before use
- The declaration of conformity is available for download on the manufacturer’s website
Warranty, guarantee and disposal
The GX-K2 is covered by the statutory warranty of at least 2 years in the EU. The manufacturer Elektrotechnik Schabus additionally offers a 5-year guarantee that can be registered online. Repairs and spare parts are available directly from the manufacturer, even beyond the statutory warranty. The prerequisite is that the device has been used in accordance with the operating instructions. Damage caused by improper use, modifications to the device, external influences or unauthorised repairs is excluded.
The GX-K2 does not belong in household waste. At the end of its service life, hand it in at a suitable collection point for waste electrical equipment (WEEE Reg. No. DE91394868) and dispose of the packaging separately according to material type. Information is available from your city or municipality.
Why the GX-K2 is suitable
Sensor in the right place
The external sensor is located close to the potential leakage source, independent of the socket.
Specifically for refrigerants
Target gas R-32 and many other fluorinated refrigerants, specially for heat pumps and air-conditioning systems.
Early and clear warning
Optical pre-alarm and loud acoustic main alarm.
Always in view
Three LEDs for operation, fault and alarm as well as a TEST button.
Sensor replaceable
The external sensor can be replaced by the user.
From the manufacturer
Made in Germany, German manufacturer since 1992, personal expert advice without call centres, ISO 9001:2015 certified.
Service included
5-year guarantee registrable, repairs and spare parts directly from the manufacturer.
Areas of application
- Heat pumps
- Private air-conditioning systems
- Refrigeration systems and refrigeration units
- Cold rooms
- Technical rooms
- Private and commercial applications in dry indoor areas
The Schabus GX-K2: sensor in the right place, detect leaks early.
Frequently asked questions
What is the GX-K2 suitable for?
It monitors the ambient air for escaping refrigerants and coolants, for example on heat pumps, air-conditioning systems and refrigeration units. Its external sensor can be positioned independently of the plug-in unit at the suitable measuring point. The system is intended for dry indoor areas.
Which refrigerants does the GX-K2 detect?
The target gas is R-32. The sensor also responds to other refrigerants, including R-410A, R-404A, R-407C, R-454B, R-1234yf, R-1234ze and R-22. Sensitivity and therefore the trigger concentration differ depending on the type of gas.
Does the GX-K2 also detect R-290 or propane?
Yes, the sensor has a cross-sensitivity to propane, which is used as refrigerant R-290. However, the GX-K2 is not explosion-proof and must not be operated in potentially explosive atmospheres. Suitability for the intended place of use must be clarified before installation.
What is the difference between GX-K1 and GX-K2?
On the GX-K1, a separate device, the sensor is integrated in the warning device and measures directly at the location of the socket. On the GX-K2 the sensor is connected via a 2.5 m long cable. This allows the measuring point to be positioned independently of the socket.
Where must the external sensor be mounted?
The height depends on the refrigerant used. For gases heavier than air, 15 to 30 cm above the floor. For lighter gases, 15 to 30 cm below the ceiling and above the highest door or window opening. The distance to the monitored system must not exceed 4 m. Observe the information provided by the system manufacturer.
How long is the sensor cable and can it be extended?
The external sensor is connected to the warning device via a 2.5 m long cable. It must not be extended or modified. Take the cable length into account when choosing the socket and sensor position.
May the external sensor be mounted outdoors?
No. Both the warning device and the external sensor are intended for dry indoor areas. The GX-K2 is not an outdoor detector. Do not place the sensor in locations with rain, splash water or condensation. Mounting directly next to the outdoor unit of a heat pump is also not intended.
Is the GX-K2 ready for operation immediately after plugging in?
The sensor requires a warm-up time of approximately 3 to 5 minutes; during this time the green LED flashes. Only when it lights continuously is the device ready for operation. After an interruption of the power supply the warm-up phase starts again.
How does the GX-K2 warn in the event of a refrigerant leak?
In the event of a pre-alarm the red LED flashes. If the concentration continues to rise, the acoustic main alarm also sounds. With the TEST button you mute the alarm tone; the red LED continues to flash as long as gas is detected. Muting does not eliminate the gas exposure or its cause.
What must I do in the event of an alarm?
Warn other people and leave the affected area. Avoid ignition sources, do not operate any electrical switches and do not unplug the warning device from the socket. Ventilate only if this is possible without danger. Have the cause checked by a specialised company. In the event of acute danger, call the emergency number 112 from a safe distance.
How do I check the function of the GX-K2?
With the TEST button you check the LEDs and the acoustic sounder, not the sensor. For the sensor test, use an R32 test aerosol on the external sensor in accordance with the application instructions of the test agent manufacturer. Do not gas the sensor directly with lighter gas. A monthly function test is recommended.
What does a flashing yellow LED mean?
A flashing yellow LED with a signal tone every 30 seconds indicates a fault, for example a sensor, cable or device fault. Check the sensor cable and the plug connection. If the fault persists, contact Schabus Support. Do not open or repair the warning device yourself.
Can the GX-K2 also react to other substances?
Yes. The sensor has cross-sensitivities, among others to methane, butane, propane, ethanol and hydrogen. Certain sprays or vapours can also trigger a warning. Always treat an alarm initially as a possible gas leak.
Does the GX-K2 also detect carbon monoxide?
No. The GX-K2 does not detect carbon monoxide and does not replace a CO detector.
How long does the sensor last and can I replace it myself?
The sensor service life is approximately 5 years. The external sensor can be replaced by the user. Observe the inspection date indicated on the sensor and coordinate factory inspection or sensor replacement in good time with Schabus Support. The plug-in unit must not be opened by the user.
Are there options or additional variants?
No. The GX-K2 has no options. With external sensor, sensor cable, mounting material and operating instructions it is complete.
How long is the guarantee valid?
The statutory warranty of at least 2 years applies in the EU. In addition, the manufacturer Schabus offers a 5-year guarantee that can be registered online.
Questions about the refrigerant warning device GX-K2?
Our support team in Germany will advise you free of charge on selection, installation and configuration.
GX-K2 Refrigerant Gas Alarm
The GX-K2 is a high-performance refrigerant gas alarm designed for the early detection of refrigerant leaks. It reliably detects flammable and non-flammable refrigerants and is suitable for use in cold rooms, technical facilities, or machine rooms.
Technical Data
- Operating voltage: 230 V AC (±10%), 50–60 Hz
- Power consumption: up to approx. 3 VA (depending on operating state)
- Protection rating: IP 20
- Sound pressure (buzzer): > 80 dB(A) @ 1 m (main alarm)
- LED indicators:
- Green flashing: warm-up phase approx. 3 minutes
- Green steady: operation / monitoring
- Yellow flashing: fault, cable break, etc.
- Red flashing: pre-alarm / main alarm - Sensor type: catalytic
- Operating temperature range (sensor): -10 °C to +50 °C
- Storage temperature range (sensor): -20 °C to +70 °C
- Ambient humidity: 5–90 % RH (non-condensing)
- Sensor lifetime: approx. 5 years
- Dimensions (H×W×D): 118 × 60 × 44 mm
- Cable length: 2.5 m (non-extendable)
- Cable diameter: 3.5 mm
- Sensor dimensions (H×W×D): 52 × 27 × 29 mm
Gas Detection
- Sensitive to: R-22, R-32, R-404A, R-410A, R-1234yf, and other HFCs
- Cross-sensitivity: methane, butane, propane (R-290), ethanol, hydrogen, and other hydrocarbons
- Not sensitive to: carbon monoxide (CO)
Alarm Levels
- Pre-alarm: 100–10,000 ppm (depending on refrigerant), 3% LEL for flammable gases
- Main alarm: e.g. R-32 from 1,000 ppm @ 20 °C ambient, 10–20% LEL (typically 12% LEL)
Manufacturer information:
Electrical engineering Schabus GmbH & Co. KG
Baierbacher Straße 150
83071 Stephanskirchen
Germany
Telephone: +49 80 36 / 674 979 – 0
Email: info@elektrotechnik-schabus.de
Responsible person:
Didactum® Security GmbH
Im Mühlenfeld 4
48163 Münster
Deutschland
Fon:
(+49) 250 19 71 63 54 / (+49) 171 33 11 577
Email: info@didactum-security.de