€91.60
The professional water detector for DIN rail: two independent detection lines, two relay outputs, cables up to 300 m
The Schabus water detector SHT 5001 monitors water leakage and water levels in control cabinets, technical rooms and systems. It is an installation device in a standardised DIN-rail housing (35 mm DIN rail) and is intended for permanent installation in a small distribution board or fuse box. The detector itself remains dry: only the water sensor or the mini float switch is located at the measuring point.
The SHT 5001 has two independent detection lines. Each line has an input for water sensors (AC), an input for mini float switches (DC) and its own potential-free changeover relay. In the event of an alarm, the red SENSOR LED lights up or flashes, the internal buzzer sounds and the common 12 V alarm output is activated. An alarm memory can be enabled for each line using a wire bridge. External devices such as signal horns, flashing lights, GSM diallers, WWD 200 or a suitable BUS interface (EIB) can be controlled via the relays.
Important note: Installation and connection may only be carried out by a qualified specialist. Connection to the mains voltage must be carried out by a qualified electrician. Before working on the terminals, switch off the supply and any connected relay loads and secure them against being switched on again. Install the SHT 5001 completely protected against moisture and only in dry indoor areas. It is not suitable for use in potentially explosive atmospheres. The water detector does not replace the proper installation, maintenance and inspection of water pipes and fittings.
Good to know: The SHT 5001 is the control unit; water detection is performed by the connected sensors. Water sensors and mini float switches are not included in the scope of delivery and must be ordered separately. The TEST button simulates water on both detection lines and checks the alarm functions of the device. The connected sensors and float switches are not checked in the process. Test these additionally directly at the point of use.
Detect water reliably and respond specifically
Two independent detection lines
One input for water sensors (AC) and one input for mini float switches (DC) per line.
Two relay outputs
Each detection line switches its own potential-free changeover relay, for example for a pump, shut-off valve, BUS system or alarm forwarding.
Alarm memory per line
Can be activated individually for each line using a wire bridge. Acknowledgement with RESET or via an external push-button.
Long cables
Up to 100 m for water sensors and up to 300 m for mini float switches, each with unshielded LIYY cable.
Flexible power supply
Operation with mains voltage or with 12 V or 24 V DC. With a connected battery, the device works as an uninterruptible power supply.
Optical and acoustic
Red SENSOR LED, green POWER LED and internal piezo buzzer that can be selectively muted.
12 V alarm output
For suitable external signalling devices such as LED or piezo sounder with its own driver, common for both lines.
Multiple detectors per input
Several water sensors or several mini float switches can be connected in parallel to one input.
For many applications
Fork sensors for conductive liquids, mini float switches for level monitoring and non-conductive liquids, switching point from approx. 4 cm level height.
What is included in the box
The SHT 5001 has no options and no additional variants. Water sensors, float switches, cables and external signalling devices are not included and are available separately.
- 1 × Water detector SHT 5001 for DIN rail
- 1 × Operating instructions
How the SHT 5001 is constructed
The SHT 5001 has all operating elements and connections on the front. The upper terminals belong to the sensors, the lower ones to the power supply and outputs. The device contains no parts that can be serviced by the user and must not be opened.
DIN-rail housing
The impact-resistant plastic housing is clipped onto a 35 mm DIN rail. It belongs in a small distribution board or fuse box.
Status indicators
The green POWER LED indicates that the device is supplied with voltage. The red SENSOR LED indicates an alarm: it lights continuously for detection line 1, flashes for detection line 2 and flashes more slowly when both lines have been triggered.
Test button and reset button
TEST simulates water on both detection lines and triggers the alarm functions. RESET acknowledges a stored alarm after the water message has ended. In the event of an active alarm without alarm memory, RESET only mutes the internal buzzer.
Upper terminals 13 to 24
These include the DC power supply (13/14), the wire bridges for the alarm memory (15/16 for line 1, 17/18 for line 2), the inputs for mini float switches (19, 20, 21) and the inputs for water sensors (22, 23, 24). Terminals 20 and 23 are common terminals for both lines.
Lower terminals 1 to 12
These include the mains connection L / N / PE (1 to 3), relay 1 with COM / NO / NC (4 to 6), relay 2 with COM / NO / NC (7 to 9), the input for an external acknowledgement button (10/11) and the 12 V alarm output (11/12).
Two detection lines with two inputs each
Detection line 1 uses terminals 19/20 for mini float switches and 22/23 for water sensors. Detection line 2 uses 20/21 and 23/24. An activated AC or DC input triggers the alarm of the respective line.
Two potential-free changeover relays
Relay 1 belongs to detection line 1, relay 2 to detection line 2. The relays operate independently of each other and provide the contacts COM, NO and NC. They do not supply any voltage themselves; the connected device requires a suitable separate power supply.
Internal piezo buzzer and 12 V alarm output
The buzzer and the alarm output report alarms from both lines jointly. Terminal 11 permanently carries +12 V; terminal 12 is the switched negative pole (open collector) in the event of an alarm. As soon as a device is connected to 11/12 or a wire bridge is fitted, the internal buzzer is muted.
Screw terminals
All connections are screw terminals. Open the screw, insert the wire or stranded conductor, then close the screw again. The screws must not be overtightened.
Correct installation and connection
Installation and connection should be carried out by a specialist. The device is installed in a dry location; only the sensor or float switch is located at the measuring point.
Installation
- Select a suitable installation location: a small distribution board or fuse box in a dry indoor area.
- Avoid unsuitable locations: directly above a cooker, combustion appliance, sink or drain, areas with dust, moisture or dirt, and potentially explosive rooms.
- Switch off the supply and any connected relay loads and secure them against being switched on again.
- Clip the SHT 5001 onto the 35 mm DIN rail.
- Fit only the water sensor or the mini float switch at the measuring point, never the detector itself.
- Carry out the complete functional test after installation and connection.
Connection
- Power supply: Mains voltage to L / N / PE (terminals 1 to 3) or DC voltage 12 V or 24 V to terminals 13/14. Mains and battery can be connected simultaneously: at 12 V the mains has priority, at 24 V the DC supply has priority. The changeover threshold is approx. 15 V
- Water sensor line 1: Terminals 22/23
- Water sensor line 2: Terminals 23/24
- Mini float switch line 1: Terminals 19/20
- Mini float switch line 2: Terminals 20/21
- Relay 1: Terminals 4 (COM), 5 (NO), 6 (NC)
- Relay 2: Terminals 7 (COM), 8 (NO), 9 (NC)
- External acknowledgement: Connect a potential-free normally open push-button with momentary action to terminals 10/11. It acts like pressing RESET; several push-buttons can be connected in parallel
- Alarm memory: Wire bridge at 15/16 for line 1 and at 17/18 for line 2. With the bridge fitted, the alarm remains stored after the message ends until RESET; relay, SENSOR indicator and alarm output 11/12 remain active until acknowledgement
- 12 V alarm output: At terminals 11/12 for suitable signalling devices such as LED, wire bridge (alarm current) or piezo sounder with its own driver. The total load is a maximum of 30 mA, even with several devices connected
Cables
- Use exclusively unshielded LIYY cable 2 × 0.14 mm²
- Water sensors (AC): cable length up to 100 m
- Mini float switches (DC): cable length up to 300 m
- The cable capacitance per detection line must not exceed 10 nF
- Never route sensor cables parallel to mains cables
- Several water sensors on the same AC input or several mini float switches on the same DC input can be connected in parallel. One is sufficient to trigger the associated detection line; the cable specifications must still be observed
What happens in the event of an alarm
Each detection line is assigned to its own relay: detection line 1 switches relay 1, detection line 2 switches relay 2. An activated input of a line triggers its alarm. The relays operate separately; the buzzer and the 12 V alarm output report both lines.
Optical
The red SENSOR LED lights continuously for line 1, flashes for line 2 and flashes more slowly when both lines have been triggered.
Acoustic
The internal piezo buzzer signals the alarm. It can be selectively muted.
Switching
The potential-free changeover relay associated with the detection line picks up.
External signalling
Flashing lights, signal horns, alarm forwarding or a BUS system can be switched via the relays. The alarm output 11/12 is available for suitable 12 V signalling devices.
Alarm memory and RESET
- Without alarm memory: The alarm ends automatically as soon as the detection line no longer triggers a message. RESET only mutes the internal buzzer while an alarm is still active; the relay remains switched until the message ends
- With alarm memory: The alarm remains stored until it is acknowledged with RESET or the external push-button at 10/11 after the water message has ended. If the message is still active, the alarm remains
- TEST with active alarm memory: The TEST alarm remains until RESET
- Buzzer muted: As soon as a device is connected to 11/12 or a wire bridge is fitted, the internal buzzer remains muted. The optical indication and relay function remain active
Water sensor or float switch?
The SHT 5001 processes both sensor types. Which one is right depends on the place of use. If technically possible, the manufacturer recommends mini float switches because they are significantly more robust and durable.
Water sensor (AC)
For normally dry surfaces, for example under appliances or near pipes. The electrodes detect conductive water. Prolonged wetting can cause corrosion and false alarms.
Mini float switch (DC)
For levels, containers, wells, shafts, tanks and prolonged water contact. Also usable with non-conductive liquids if the switch used is suitable for this. Switching point from approx. 4 cm level height.
Per detection line you can operate sensors on both inputs, i.e. one water sensor and one mini float switch. Each line evaluates its inputs independently and switches its own relay.
Changeover float switch and AND circuit
Changeover float switch on terminals 19/20/21
A mini float switch with changeover contact uses three cores on both detection lines: 19 = green (NC), 20 = brown (COM) and 21 = white (NO). One of the two detection lines is always active and the associated relay is picked up. The changeover switch occupies both DC inputs. Leave the alarm memory bridges 15/16 and 17/18 open for this mode of operation. A bridge at 11/12 mutes the internal buzzer.
Example solenoid valve, closed when de-energised: Relay 1 switches the valve via terminal 4 (COM) and terminal 5 (NO). When the level rises or in the event of a power failure, relay 1 drops out and the valve closes when de-energised. The specific valve and relay load must be correctly rated by a specialist.
AND circuit: alarm only when both lines are triggered
If a circuit is only to close when both detection lines have been triggered, the normally open contacts of both relays are connected in series: relay 1 via terminals 4-5 (NO), relay 2 via 7-8 (NO), and terminals 5 and 7 are bridged together. The load circuit between 4 and 8 is only closed when both relays pick up. A single triggered input does not close the load circuit.
The three-contact sensor SHT 5008 (Art. No. 300719) is suitable for this: green to terminal 22, brown to terminal 23, white to terminal 24. The middle contact forms two separate measuring paths with the two outer contacts; both contact pairs must be wetted for both lines to trigger. Alternatively, two separate sensors at 22/23 and 23/24 form the same AND function. When testing, wet both contact pairs.
Testing, cleaning, finding faults
Functional test
- Device test: Press TEST. All alarm functions are triggered. With active alarm memory the TEST alarm remains until RESET.
- Test sensors at the point of use: Wet the water sensors or actuate the mini float switches. TEST does not check these connections.
- Observe the response: Check the indication, buzzer and the connected devices, for example signal horn, valve or pump, in a controlled manner.
- Restore normal condition: End the water message and acknowledge a stored alarm with RESET or the external push-button.
Cleaning and care
- Protect the device against moisture, dust and direct sunlight
- Clean with a dry cloth, slightly damp if necessary
- Do not use solvent-based agents
- Check sensor electrodes for dirt and corrosion
- Check float switches for free movement
- Test sensors and float switches regularly at the point of use
- Do not open the device; repairs only by the manufacturer or authorised specialist personnel
Troubleshooting
- POWER LED off? Have the supply, cables and protection checked by a specialist: mains at 1 to 3 or DC at 13/14
- Unexpected alarm? Identify the affected line via the SENSOR LED. Check the measuring point for moisture, dirt or switch position
- Alarm remains? Are 15/16 or 17/18 bridged? RESET only works for a stored alarm after the message has ended. Check the measuring point again
- No buzzer sound? A connection or bridge at 11/12 mutes the internal buzzer. Have the wiring checked
- Repeated false alarms? Have sensors and cables checked for damage or contamination
- If the fault persists, contact Schabus Support. Do not open the device and do not repair it yourself
Behaviour in the event of an alarm
- Avoid the danger area: Keep your distance if there is water near electrical systems, do not touch wet parts and call in a specialist.
- Identify the detection line: SENSOR LED lights continuously: line 1. It flashes: line 2. If it flashes more slowly, both lines are activated.
- Eliminate the cause: Check for leakage or rising level. Secure the water supply or connected system only if it is safe to do so. Check the measuring point.
- Acknowledge only afterwards: After the message has ended, reset a stored alarm with RESET or the external push-button at 10/11.
Suitable accessories (available separately)
The SHT 5001 itself has no options. The following proprietary articles complement it for detection, signalling and extension.
- Water sensors: Fork sensors, floor sensors and cable sensors for detecting conductive water on dry surfaces
- Mini float switches: For level monitoring, containers, wells, shafts, tanks and non-conductive liquids; in suitable versions also as changeover switches
- Three-contact sensor SHT 5008 (Art. No. 300719): For AND circuits with two measuring paths
- LIYY control cable 2 × 0.14 mm² (sold by the metre): For extending the detection lines. Use exclusively unshielded LIYY cable and observe the cable lengths and cable capacitance
- Signal horn: As external signalling device via relay or alarm output
- Flashing light: As optical external signalling device
- Combined warning light: For buildings, technical rooms or industrial plants with increased warning requirements
- GSM dialler and WWD 200: For alarm forwarding via the potential-free relay contacts
What the SHT 5001 is not
- It is not a substitute for the proper installation, maintenance and inspection of water pipes and fittings
- It is not intended for wet environments; the control unit itself must be installed in a dry indoor area
- It is not suitable for potentially explosive atmospheres
- Via TEST it only checks its own alarm functions, not the connected sensors
- The 12 V alarm output is only intended for suitable signalling devices, not for larger loads. Connect piezo sounders only with their own driver
- The relay contacts are potential-free and do not supply any operating voltage. Switching capacity and connected loads must be correctly rated by a specialist
- A water sensor is not intended for permanently moist environments; mini float switches are suitable for this
- The manufacturer is not liable for damage resulting from improper use, modifications to the device or failure to observe the operating instructions
Manufacturer’s notes
- Read the operating instructions carefully before installation and commissioning, pay particular attention to the safety notes and keep the instructions
- Installation and connection only by a qualified specialist. Connection to the mains voltage must be carried out by a specialist
- Before working on the terminals, switch off the supply and any connected relay loads and secure them against being switched on again
- Take account of the mains voltage and connected relay loads
- The device must not be used by children or persons with reduced physical, sensory or mental capabilities unless they are supervised or have been instructed in safe use
- The SHT 5001 is intended for use in residential, commercial and light industrial areas as well as in small businesses, for example in residential buildings, sales areas or rooms of commercial enterprises with household-like use
- Do not open the device; there are no parts inside that can be serviced or repaired by the user
- Packaging material must be kept out of the reach of children
- Always carry out the complete functional test after installation, connection or modification
- The EU declaration of conformity can be requested from the manufacturer or downloaded from the manufacturer’s website
Warranty, guarantee and disposal
The SHT 5001 is covered by the statutory warranty of at least 2 years in the EU. In the event of material defects and quality deficiencies, the manufacturer repairs or replaces the device free of charge provided it has been used in accordance with the operating instructions. In addition, Elektrotechnik Schabus offers a 5-year guarantee that can be registered online. Repairs and spare parts are available directly from the manufacturer, even beyond the statutory warranty.
The device bears the CE marking. The declaration of conformity can be found on the manufacturer’s website.
The SHT 5001 must not be disposed of with household waste. The crossed-out wheeled bin symbol reminds you to use the take-back systems so that the materials can be reused in an environmentally friendly manner at the end of their service life (WEEE Reg. No. DE91394868). Further information is available from your local waste advice centre or from the manufacturer.
Service and returns
In the event of a service case, first contact the manufacturer and describe the fault as precisely as possible: what has happened, when does it occur and what indication does the device show? Many questions can already be resolved by telephone or e-mail. In the event of a warranty claim, a description of the fault, proof of purchase and your complete contact and delivery details are required.
If necessary, after consultation pack the device securely against breakage and enclose a description of the fault, contact details and a copy of the proof of purchase. The manufacturer cannot accept unfranked shipments. Repairs and maintenance may only be carried out by the manufacturer or authorised specialist personnel. Service hours are Monday to Thursday from 8:00 a.m. to 12:00 p.m. and from 1:00 p.m. to 5:00 p.m. and Friday from 8:00 a.m. to 12:00 p.m.
Why the SHT 5001 is suitable
Two lines, two relays
Two independent detection lines, each with its own potential-free changeover relay.
For long distances
Cables up to 100 m for water sensors and up to 300 m for mini float switches.
Flexible power supply
Mains voltage, 12 V or 24 V DC, with battery as uninterruptible power supply.
Needs-based alarm memory
Can be activated individually for each line using a wire bridge, acknowledgement via RESET or external push-button.
Many signalling paths
LED, buzzer, 12 V alarm output and relays for horn, GSM dialler, WWD 200 or BUS system.
From the manufacturer
Made in Germany, German manufacturer since 1992, personal specialist advice without call centre, ISO 9001:2015 certified.
Service included
5-year guarantee can be registered, repairs and spare parts directly from the manufacturer.
Areas of application
- Control cabinets and sub-distribution boards
- Technical rooms
- Flat roofs
- Cisterns
- Pump sumps
- Shafts
- Industrial plants
- Level monitoring in containers, tanks and wells
- Water shut-off via a solenoid valve
- Pump control and alarm forwarding
The Schabus SHT 5001: Because a drop should not become a flood.
Frequently asked questions
How is the SHT 5001 powered?
The SHT 5001 can be operated with mains voltage or with 12 V or 24 V DC. If a battery is also connected, it takes over the supply in the event of a power failure and the device then works as an uninterruptible power supply. At 12 V the mains has priority, at 24 V the DC supply has priority. The changeover threshold is approx. 15 V. The mains connection may only be carried out by a specialist.
Which sensors can I connect and when do I use which one?
Water sensors are suitable for normally dry environments, for example under washing machines, dishwashers or in technical rooms. They should not be exposed to permanently moist environments. Mini float switches are suitable for permanently moist zones, for level monitoring, for non-conductive liquids and for wells, shafts or tanks. The manufacturer recommends always using mini float switches if technically possible, as they are more robust and durable.
How long may the cables to the sensors be?
Up to 100 m for water sensors, up to 300 m for mini float switches. The prerequisite is unshielded LIYY cable 2 × 0.14 mm². The cable capacitance per detection line must not exceed 10 nF. Do not route the cables parallel to mains cables in order to avoid interference.
What does alarm memory mean and how does it work?
With a wire bridge at 15/16 (line 1) or 17/18 (line 2), a triggered alarm remains stored until it is reset, using the RESET button on the front or an external push-button at terminals 10/11. Without alarm memory the alarm ends automatically as soon as no more water is reported. The function can be selected separately for each of the two detection lines. With a stored alarm the associated relay, the SENSOR indication and the alarm output 11/12 remain active until acknowledgement.
How is the alarm signalled?
In the event of water contact or level exceedance, the red SENSOR LED lights up or flashes, the internal buzzer sounds, the changeover relay associated with the line switches and the common 12 V alarm output is activated. Both detection lines trigger separate relays; buzzer and alarm output apply jointly to both lines.
How many sensors can I connect per detection line?
Each detection line has one AC input for water sensors and one DC input for mini float switches. Several suitable sensors or float switches can be connected in parallel to one input. As soon as one of them responds, the associated detection line is triggered. All detectors on one line jointly switch the associated relay. The specifications for cable length and cable capacitance must be observed.
Does the TEST button also check the connected sensors?
No. TEST simulates water on both detection lines and checks the alarm functions of the device. Water sensors and mini float switches are not checked in the process. These must additionally be tested at the point of use by wetting the sensors or actuating the float switches.
How can I tell which detection line has been triggered?
The red SENSOR LED indicates the affected line: for detection line 1 it lights continuously, for detection line 2 it flashes. If both lines are activated, it flashes more slowly. The green POWER LED indicates that the device is supplied with voltage.
Why is the SENSOR LED lit even though no warning tone can be heard?
The internal buzzer is muted as soon as a device is connected to 11/12 or a wire bridge is fitted. In the event of an active alarm without alarm memory, pressing RESET also mutes the buzzer. The optical indication and the relay function remain active.
What happens if the alarm does not stop?
First check whether the sensor is still reporting water, because as long as the alarm condition exists the alarm remains. If there is no more water and the alarm still does not stop, the alarm memory is probably active: a stored alarm can only be reset with RESET or the external push-button after the water message has ended. Then check whether the bridges 15/16 or 17/18 are fitted.
Can I end an still active water alarm with RESET?
No. As long as the sensor or float switch continues to report water, the alarm condition remains. In the case of an alarm without memory, RESET only mutes the internal buzzer; the associated relay remains switched.
Can the SHT 5001 switch a pump or a shut-off valve?
Yes, the two potential-free changeover relays can switch suitable external devices. Potential-free means that the relay contacts themselves do not provide any operating voltage: the connected device requires a suitable power supply. Connection and dimensioning must be carried out by a specialist. The separate 12 V alarm output is only intended for suitable signalling devices with a maximum of 30 mA.
May I install the SHT 5001 directly in a damp shaft or outdoors?
No. The control unit must remain dry and be installed in a dry indoor area; it offers no protection against water. Only the sensor or float switch suitable for the application is fitted at the monitored location. Suitable float switches must be used for permanently present water contact.
Can a circuit only react when two sensors report water at the same time?
Yes, with an AND circuit. For this the normally open contacts of both relays are connected in series (relay 1: 4-5, relay 2: 7-8, terminals 5 and 7 bridged). The circuit then only closes when both detection lines have been triggered. This is possible with the three-contact sensor SHT 5008 or with two separate water sensors. The connection example is in the operating instructions.
How do I switch a solenoid valve so that it is closed when de-energised?
Connect the valve via relay 1 to terminals 4 (COM) and 5 (NO). When the level rises or in the event of a power failure, relay 1 drops out and the valve closes when de-energised. For this a mini float switch with changeover contact is used on terminals 19/20/21; the alarm memory bridges remain open. The specific valve and relay load must be correctly rated by a specialist.
Do sensors and float switches need to be checked regularly?
Yes. Check water sensors for contamination and corrosion and float switches for free movement. Test the function directly at the point of use; the TEST button on the SHT 5001 does not replace this check. In the event of repeated false alarms, sensors, cables and connections should be checked by a specialist.
Are there options or additional variants?
No. The SHT 5001 has no options. Sensors, float switches, extension cable and external signalling devices are separate accessory articles. Note the article number: the SHT 5001 has the article number 400748.
How long is the guarantee valid?
The statutory warranty of at least 2 years in the EU applies. In addition, the manufacturer Schabus offers a 5-year guarantee that can be registered online.
Questions about the water detector SHT 5001?
Our support team in Germany will advise you free of charge on selection, installation and configuration.
Water Detector SHT 5001 – DIN Rail
The SHT 5001 is a professional water detector designed for mounting on a 35 mm DIN rail. It is suitable for industrial use, building automation, and safety-related installations. The device supports both AC sensors and DC mini float switches and offers two potential-free changeover relays.
Technical Data
- Operating voltage: 100–240 V AC / 50–60 Hz or 12–24 V DC (battery)
- Power consumption: approx. 2–3 W / VA (depending on operating mode)
- Switching capacity: max. 250 V~ / 30 V= / 5 A
- Operating temperature range: +5 °C to +45 °C
- Storage temperature: –20 °C to +70 °C
- Protection class: IP 20 (for dry indoor areas)
- Humidity range: 5–90 % rH (non-condensing)
- Dimensions (H×W×D): 90 × 72 × 57 mm (4 DIN rail modules)
Sensor & Measurement
- Detection lines: 2 sensors (AC) and/or 2 mini float switches (DC)
- Measuring voltage: AC 115 Hz / 2.5 Vpp, DC 12 V
- Alarm threshold: AC < 80 kΩ / DC < 180 kΩ
- Cable lengths: AC up to 100 m, DC up to 300 m (max. 10 nF)
Alarm & Relays
- Alarm output: 12 V / max. 30 mA
- Sound pressure level: 65 dB(A) (10 cm distance), piezo buzzer
- Relay contacts: 2 potential-free changeover relays
Manufacturer information:
Electrical engineering Schabus GmbH & Co. KG
Baierbacher Straße 150
83071 Stephanskirchen
Germany
Telephone: +49 80 36 / 674 979 – 0
Email: info@elektrotechnik-schabus.de
Responsible person:
Didactum® Security GmbH
Im Mühlenfeld 4
48163 Münster
Deutschland
Fon:
(+49) 250 19 71 63 54 / (+49) 171 33 11 577
Email: info@didactum-security.de