€449.00
The industrial GSM remote monitoring system for sites without LAN access
The HW group Ares 12 is an industrial device for remote monitoring and alarm notification via GSM, designed for sites without LAN access. It features an internal battery for power-failure backup and supports the connection of up to 14 external sensors as well as 2 digital dry-contact inputs for detectors.
The Ares 12 continuously monitors the readings of connected sensors. When a value reaches the alarm threshold, the device sends an email, an SMS, or calls predefined telephone numbers. The SensDesk portal can be used to configure the Ares, send alarms, and display measured values in graphs. The firmware can be updated remotely via FOTA (Firmware Over The Air), making the Ares 12 ideal for large-scale installations.
Up to 14 sensors and 2 detectors – even without LAN
The Ares 12 connects to the Internet exclusively via GSM/GPRS, making it suitable for locations without a network connection.
GSM/GPRS modem
Quad-band GSM/GPRS modem (850/900/1800/1900 MHz, GPRS Class 10/8) for worldwide cellular connectivity (SIM card not included).
14x 1-Wire / 1-Wire UNI (RJ11)
Connection for up to 14 sensors via an RJ11 bus (maximum total length: 60 m), for example temperature, humidity, current, voltage, or water leak detection.
2x DI with S0 pulse counter
Two digital inputs (dry contact, NO/NC) with 32-bit pulse counters that retain their values even during a power outage—ideal for electricity, gas, or water meters.
Internal battery backup
Rechargeable Li-Ion battery (1300 mAh) bridges power outages for up to 24 hours.
5x email / 5x SMS + call
Alarm notification by calling and sending text messages to up to 5 telephone numbers, as well as emails to up to 5 addresses; alternatively through the SensDesk portal.
Remote configuration & FOTA
Configuration locally via USB or remotely through the "AresConf" tab in the SensDesk portal; over-the-air firmware updates for large-scale installations.
Choose individually: base unit or starter kit
The HWg-Ares 12 is available either as a base unit only or as a complete starter kit with accessories.
Please note: The "HWg-Ares 12 plain" base unit does not include a power supply, antenna, or sensors. Only the "HWg-Ares 12 Tset" version includes the complete starter kit with accessories. The option must be selected before adding the product to the shopping cart.
HWg-Ares 12 plain
Ares12 base unit (2x DI, 14x 1-Wire UNI sensor inputs, internal battery). Device only, without additional accessories.
HWg-Ares 12 Tset
Ares 12 starter kit with universal power supply (US, EU, UK), temperature sensor, quad-band GSM antenna (3 m), HWg-Ares 12 base unit, mounting plate, and USB cable for configuration.
How the HWg-Ares 12 is designed
The robust metal enclosure is compact, measuring approximately 76 x 93 x 31 mm (W x H x D) and weighing about 150 g. It has an IP40 protection rating and is designed for operating temperatures from 5°C to 50°C.
Metal enclosure for desk, wall, rack, or DIN rail
Robust metal enclosure for industrial use, suitable for installation on a desk, wall, rack, or DIN rail (mounting plate included with the Tset).
SIM card slot with external GSM antenna
A SIM card slot and a connector for the quad-band GSM antenna (3 m, included with the Tset) establish the cellular connection.
2x RJ11 sensor connections ("Sensors")
Two RJ11 ports for 1-Wire and 1-Wire UNI sensors, allowing up to 14 sensors in total to be connected via a bus with a maximum length of 60 m.
DI terminals (IN1, IN2)
Two screw terminals for digital inputs (NO/NC dry contacts) with pulse-counter functionality, for example for detectors or meters; the right-hand terminal can be connected to 12V GND. Maximum cable length: 50 m.
Power supply (9–30V) with battery backup
Power is supplied through a barrel connector socket (Ø 2.1/5.5 mm) or a terminal block with 9–30 V DC (approximately 250 mA for each connection method). An internal rechargeable Li-Ion battery bridges power outages for up to 24 hours. The Tset includes a matching universal power supply (US, EU, UK).
USB connection and status LEDs
The USB connection (cable included with the Tset) enables the device to be configured directly from a PC without additional software. LEDs on the front of the device indicate power, modem, and alarm status.
Long-term storage and integration with third-party systems
The Ares 12 stores measurement values locally, even when the connection is interrupted.
- Integrated data logger for more than 250,000 records (4 MB memory)
- Data can be sent as an email attachment or downloaded via USB
- Data display through the SensDesk portal, its iOS/Android app, or third-party software such as Nagios
- The HWg-PDMS software can convert S0 pulses into costs per period and export them to MS Excel
- Compatible with third-party software such as SCADA systems; developer examples are available in the HWg SDK (Borland C++, MS Visual, VB, C#, PHP, Java, and others)
- Data transmission to the SensDesk portal via the HWg-Push protocol
A sensor value outside the defined safe range or a status change at a DI input triggers an alarm by email or "SMS + call", or activates a relay using the optional "Relay Output 1-Wire UNI" accessory.
Reliable notification even without LAN
The Ares 12 sends alarms directly through the cellular network—independently of an on-site Internet connection.
Standalone device alarms
Email to up to 5 addresses (SMTP with TLS), as well as SMS messages and voice calls to up to 5 telephone numbers directly from the device.
Portal alarms (SensDesk)
Alarm notification and reporting can be implemented entirely through the SensDesk portal, including alarm reminders and periodic status reports.
Relay outputs via accessories
With the optional "Relay Output 1-Wire UNI" module, up to 4 relay outputs (up to 50V/1000mA) can be remotely controlled.
Advanced conditions
Email and SMS templates, as well as alarm reminders, help make recurring alarms clear and traceable.
Compatible with numerous HWg sensors
Up to 14 sensors can be connected to the RJ11 sensor bus.
- Motion detector
- Water detector
- Door contact
- Gas detector
- Smoke detector
- Electricity meter
- Gas meter (pulse counter)
- Water meter (pulse counter)
Electricity, gas, and water meters can be connected through the DI inputs with pulse-counter functionality; external relay outputs can be retrofitted using the "Relay Output 1-Wire UNI" accessory.
Commissioning in just a few steps
The Ares 12 can be configured locally via USB, without additional software, or remotely through the SensDesk portal.
- Mount the device on a desk, wall, or DIN rail (mounting plate included with the Tset)
- Insert the SIM card and screw on the GSM antenna (antenna included with the Tset; SIM card available separately)
- Connect the power supply (9–30 V DC; a power supply unit is already included with the Tset)
- Connect the device to a PC using the USB cable and configure it locally, or use the SensDesk portal for remote configuration ("AresConf")
- Connect 1-Wire or 1-Wire UNI sensors to the RJ11 ports
- Optional: connect detectors to the DI terminals (IN1, IN2)
- Set alarm thresholds and email, SMS, and call recipients
- Optional: configure integration with the SensDesk portal
Why the HWg-Ares 12 is the right choice
Independent of LAN
Remote monitoring via GSM/GPRS for sites without a network connection.
Battery backup
The internal battery bridges power outages for up to 24 hours.
Up to 14 sensors
Extensive sensor connectivity through a single RJ11 bus.
FOTA capable
Remote firmware updates, ideal for large installations.
Robust metal enclosure
Designed for industrial environments and suitable for versatile installation.
24-month warranty
According to the manufacturer, covered by a 24-month warranty from the date of purchase.
Practical application examples
- GPRS monitoring of machinery and its environment
- ATMs—environmental monitoring without interfering with their connectivity
- Art exhibitions and storage facilities
- Storage facilities for food or materials
- Refrigeration systems and cooling equipment
Practical example: In a remote warehouse without a LAN connection, the Ares 12 monitors the temperature of a cold room using a 1-Wire UNI sensor and the status of a door contact connected to a DI input. If the threshold is exceeded or the door is opened, the device immediately sends an SMS and places a call to the responsible personnel—independently of any local Internet connection.
Frequently asked questions
What is the HW group HWg-Ares 12 and what is it used for?
The HWg-Ares 12 is an industrial remote monitoring device for sites without LAN access. It connects via GSM/GPRS, monitors up to 14 sensors and 2 digital inputs, and sends alerts by email, SMS, or telephone call. Typical applications include machinery, ATMs, art storage facilities, food storage facilities, and cooling systems.
What is the difference between "plain" and "Tset"?
"HWg-Ares 12 plain" includes only the base unit (2x DI, 14x 1-Wire UNI sensor inputs, internal battery), without additional accessories. "HWg-Ares 12 Tset" also includes a universal power supply, temperature sensor, quad-band GSM antenna (3 m), mounting plate, and USB cable for configuration. The option is selected before adding the product to the shopping cart.
Does the Ares 12 require a LAN connection?
No. The Ares 12 does not have Ethernet and connects exclusively via the cellular network (GSM/GPRS). It is specifically designed for sites without a network connection.
How many sensors and detectors can be connected?
Up to 14 sensors can be connected via the RJ11 bus (maximum total length: 60 m). In addition, 2 digital inputs (IN1, IN2) with pulse counters are available for external dry-contact detectors (maximum cable length: 50 m).
What happens during a power outage?
The Ares 12 has an internal rechargeable Li-Ion battery (1300 mAh) that keeps the device operating for up to 24 hours during a power outage, allowing monitoring and alarm notification to continue.
How is the Ares 12 configured?
Locally via the USB connection directly from a PC, without additional software, or remotely through the "AresConf" tab in the SensDesk portal. Firmware updates can also be installed remotely via FOTA (Firmware Over The Air).
Questions about the HWg-Ares 12?
Our support team in Germany provides free advice on product selection, sensors, and configuration.
- HWg-Ares 12 Plain:
Includes the base unit with 14x 1-Wire UNI/1-Wire inputs
2x digital inputs with S0 pulse counters, internal battery, and USB cable for configuration
Without additional accessories. - HWg-Ares 12 Tset:
Includes the base unit (as in the Plain model) as well as a temperature sensor (3 m cable, extendable up to 60 m), a QuadBand GSM antenna (3 m), a universal power adapter (US, EU, UK), and a mounting plate for easy installation.
GSM/GPRS Connection:
- Quad-band 850/900/1800/1900 MHz, GPRS class 10/8
- GSM phase 2/2+ compliant
- Class 4 (2 W @ 850/900 MHz), Class 1 (1 W @ 1800/1900 MHz)
- Supported protocols: IP, TCP, UDP, HTTP, SNTP, SMTP, HWg-PUSH
Sensors:
- Up to 14 sensors via 1-Wire UNI
- RJ11 connector (1-Wire bus)
- Sensor range: up to 60 m
- HWg original accessories: 1-Wire & 1-Wire UNI
Digital Inputs:
- 2× DI (I1, I2) for external detectors
- Supports NO/NC dry contacts
- Sensitivity: 1 (On) = 0-500 Ω
- Maximum distance: up to 50 m
Power Supply:
- Input voltage: 9-30 V DC
- Current consumption: typically 500 mA
- Connection: Jack (2.1 mm inner, 5.5 mm outer) + terminal block
- Internal battery for up to 24 hours backup
Physical Parameters:
- Operating temperature: +5 to +50 °C (+41 to +122 °F)
- Storage temperature: -25 to +85 °C (-13 to +185 °F)
- Dimensions: 76 × 93 × 31 mm
- Weight: 150 g
- Mounting: Wall or DIN rail
Alerting:
- 5× email notifications
- 5× SMS + voice call
- Alerting via SensDesk portal
- Supports iOS and Android mobile apps
Configuration & Features:
- Remote configuration via SensDesk portal
- FOTA (Firmware Over The Air) for mass deployment
- USB data port for local configuration
- Data logging with email attachments or USB download
EMC Certification:
- FCC Part 15, Class B
- CE - EN 55022, EN 55024, EN 61000
Manufacturer information:
HW group s. r. o.
Rumunská 26
Prague, 120 00
Czech Republic
Phone: +420 222 511 918
Email: sales@hwg.cz
Responsible person:
Didactum® Security GmbH
Im Mühlenfeld 4
48163 Münster
Deutschland
Fon:
(+49) 250 19 71 63 54 / (+49) 171 33 11 577
Email: info@didactum-security.de