The MID-certified three-phase meter for operation with current transformers
The HW group Meter 3f PRO380-Mb x/5A M-Bus is a static three-phase energy meter for indirect measurement via external current transformers (CTs) with an M-Bus interface. It measures and displays a range of instantaneous values, including voltage, current, active power, reactive power, apparent power, mains frequency and power factor – some of these values on the LCD display and others additionally via M-Bus.
MID-compliant for billing purposes: The PRO380-Mb x/5A complies with the Measuring Instruments Directive (MID) 2014/32/EU. This MID approval confirms the meter’s accuracy and quality and permits its use for billing purposes, for example in consumption-based cost allocation in multi-unit buildings.
For indirect measurement with current transformers: Unlike the direct-measurement version, this meter is not connected directly to the full load current. Instead, it is connected to external current transformers (CTs), which reduce the primary current to a secondary current of x/5A. This also makes the meter suitable for considerably higher currents than direct measurement would allow. The PRO380 series is also available as a standard version, a dual-tariff version, and with M-Bus and pulse output.
Indirect measurement, M-Bus and pulse output in one device
The PRO380-Mb x/5A combines precise energy measurement via current transformers with several data transmission options.
Indirect measurement via CTs
Three-phase measurement at 3x230V/400V via external current transformers with an x/5A secondary current.
MID-certified
Compliant with the Measuring Instruments Directive 2014/32/EU and suitable for billing purposes.
M-Bus interface
Digital reading of meter data via M-Bus in accordance with EN13757-3.
S0 pulse output
Additional forward and reverse pulse outputs for remote reading or accuracy testing.
Comprehensive measured values
Voltage, current, active, reactive and apparent power, mains frequency and power factor for each phase.
Infrared interface
Reading and configuration via PC software using an optical infrared interface.
How the PRO380-Mb x/5A is designed
The PRO380-Mb x/5A is housed in flame-retardant PC plastic and is designed for installation on a 35 mm DIN rail.
Housing and front cover
The housing is made of flame-retardant PC plastic and has a transparent, coloured protective cover over the connection terminals. The device weighs approximately 0.39 kg and clips onto a 35 mm DIN rail.
Two-line LCD display
A multifunctional 8-digit LCD display shows the current measured value in the upper line and the unit, phase and/or direction in the lower line. The blue backlight can be permanently switched on, switched off or activated by pressing a button.
Two control buttons
Two buttons on the front are used to scroll through the display pages and configure the device. Depending on the hold time (1, 3 or 5 seconds), the buttons are used for scrolling, opening a menu or confirming a setting.
Red status LED
A red LED on the front flashes proportionally to the measured energy flow – 10,000 pulses per kWh. The faster it flashes, the more power is currently flowing through the connected current transformers.
CT input terminals (CT1–CT3)
Instead of the phase conductors, the secondary cables of the three external current transformers (CT1, CT2 and CT3) are connected here on the input and output sides. The scaled measuring current (x/5A) is supplied through these connections.
Voltage measurement terminals (UL1–UL3, UN)
In addition to the CT inputs, the meter has dedicated terminals for measuring the voltage of each phase (UL1, UL2 and UL3) and for the neutral conductor (UN), as the voltage must be measured separately during indirect measurement.
S0 pulse outputs
Two electrically isolated open-collector outputs (terminals 18/19 for forward pulses and 20/21 for reverse pulses) output energy consumption proportionally as pulses. In this version, the outputs are always based on a CT ratio of 5/5.
M-Bus communication terminals
Digital M-Bus communication in accordance with EN13757-3 takes place via terminals 22/23.
External tariff input
External 230V AC voltage can be applied to terminals 24/25 to switch between tariffs T1 and T2.
Infrared port
The meter can be read and configured by direct contact using an optional infrared reading head and PC software via the optical infrared interface (IEC62056-21:2002 protocol).
Set the current transformer ratio before commissioning
Important note: The CT ratio must be programmed before commissioning and cannot be changed afterwards. An incorrectly configured CT ratio can result in incorrect billing values.
When switched on for the first time, the meter automatically prompts for the CT ratio.
- After switching on, the display shows “SEt Ct – CTx 0005”
- Select the secondary current /1 or /5
- Confirm by holding both buttons simultaneously for 3 seconds
- Enter the four-digit primary current (0001–9999)
- Confirm each digit individually by holding both buttons for 3 seconds
- The CT ratio is permanently stored after the final digit has been confirmed
What the PRO380-Mb x/5A displays
The meter displays a wide range of instantaneous values, individually for each phase and as a total value.
- Voltage for each phase (L1, L2 and L3)
- Current for each phase (L1, L2 and L3), based on the programmed CT ratio
- Total and phase-specific active power
- Total and phase-specific reactive power
- Total and phase-specific apparent power
- Total and phase-specific power factor (COS)
- Mains frequency
- Active and reactive energy, each as total, forward and reverse energy
For energy consumption, the display shows up to 99999.99 kWh and automatically changes to the format 999999.9 kWh above this value. A daily counter for forward energy is also available and can be reset by the user.
Digital reading in accordance with EN13757-3
The M-Bus interface digitally transmits meter data to a higher-level system, such as an M-Bus level converter or an HW group device with an M-Bus master.
- Factory baud rate 2400, adjustable to 300/600/1200/4800/9600
- Data format: 8 data bits, even parity, 1 stop bit (fixed and not changeable)
- Range up to 1000 m, cable type JYSTY (nx2x0.8)
- Up to 64 meters on one M-Bus line, depending on the level converter, baud rate and installation conditions
- Factory primary address 00; secondary address preset to the last 8 digits of the serial number
- Primary and secondary addresses and the baud rate can be changed via infrared or M-Bus
Display, buttons and configuration
The display and numerous settings can be controlled directly on the meter using the buttons.
- Automatic page change every 10 seconds, adjustable from 1 to 30 seconds
- Manual scrolling through all display pages using the buttons
- Individual measured values can be added to or removed from the automatic display sequence
- Backlight optionally permanently on, off or activated by pressing a button
- Total energy calculation method (Combination Code) selectable from seven options, such as forward only, reverse only or forward minus reverse
- Configuration menu (Program mode 3) protected by a four-digit password, factory setting 0000
Installation on a DIN rail
- Installation on a 35 mm DIN rail inside a control cabinet
- Installation only by qualified personnel
- Installation on a fire-resistant wall in a dry and well-ventilated environment
- Installation in an additional protective enclosure in dusty or otherwise contaminated environments
- After installation, the meter should be sealed to protect it against tampering
- Use of surge protection is recommended in environments with frequent voltage spikes, for example due to thunderstorms or welding equipment
For reliable continuous operation in control cabinets
- Operating temperature from -25 °C to +55 °C at 0 to 75 % relative humidity
- Storage temperature from -25 °C to +55 °C at 5 to 95 % relative humidity
- Accuracy class B (corresponding to 1 % measurement accuracy)
- IP51 protection against dust and dripping water
- Insulated, encapsulated meter with protection class II
- MID-certified in accordance with 2014/32/EU, dielectric strength 4 kV for 1 minute and impulse withstand voltage 6 kV
- 24-month manufacturer’s warranty
What is included in the delivery
Please check the delivery for completeness upon receipt and report any missing or damaged parts to your supplier immediately.
- Meter 3f PRO380-Mb x/5A M-Bus1 unit
Note: External current transformers (CTs) are required for indirect measurement, but are not included with the meter and must be purchased separately to match the respective installation.
Why the PRO380-Mb x/5A is a suitable choice
MID-certified
Suitable for consumption-based billing.
For high currents
Suitable for installations above the direct-measurement limit when used with current transformers.
M-Bus & S0
Digital remote reading and a conventional pulse output in one device.
Comprehensive measured values
Voltage, current, power and more can be viewed for each phase.
DIN rail installation
Space-saving installation in a control cabinet.
Dual-tariff capable
Switching between two tariffs via an external input.
Practical application examples
- Consumption measurement on main supply lines with currents above the direct-measurement limit
- Consumption-based billing in commercial and industrial buildings with existing current transformers
- Sub-metering of individual outgoing circuits in transformer stations or main distribution boards
- Integration into building management and energy management systems via M-Bus
- Centralised acquisition of several meters via an M-Bus master such as HWg-PWR or Perseus Energy
Frequently asked questions
What is the HW group Meter 3f PRO380-Mb x/5A M-Bus and what is it used for?
The PRO380-Mb x/5A is an MID-certified three-phase energy meter for indirect measurement via external current transformers with an M-Bus interface. Thanks to its MID approval, it is also suitable for billing purposes in installations with higher currents.
How does this meter differ from the direct-measurement PRO380-Mb 100A version?
The PRO380-Mb x/5A is connected via external current transformers (CTs), which reduce the primary current to a secondary current of x/5A. It measures current and voltage via separate terminals. In contrast, the 100A version is connected directly to the full load current and operates without external current transformers.
Are the current transformers included in the delivery?
No. External current transformers are required for operation, but must be purchased separately to match the respective installation.
How is the CT ratio configured?
When switched on for the first time, the meter automatically prompts for the CT ratio: first the secondary current (/1 or /5), followed by the four-digit primary current. Each entry is confirmed by holding both buttons simultaneously for 3 seconds. The CT ratio must be programmed before commissioning and cannot be changed afterwards.
How can the data be read?
The data can be read digitally via the M-Bus interface in accordance with EN13757-3. An S0 pulse output and an infrared interface for direct reading via PC software are also available.
How many meters can be operated on one M-Bus line?
Up to 64 meters per bus, depending on the M-Bus level converter, the selected baud rate and the installation conditions.
How is the PRO380-Mb x/5A installed?
The meter clips onto a 35 mm DIN rail and should be installed on a fire-resistant wall in a dry and well-ventilated environment.
Does the PRO380-Mb x/5A support two tariffs?
Yes. An external 230V AC input at terminals 24/25 can be used to switch between tariffs T1 and T2.
Questions about the PRO380-Mb x/5A?
Our support team in Germany provides free advice on selection, installation and configuration.
HW-group Meter 3f PRO380-Mb x/5A M-Bus
General Data
- Three-phase energy meter for current transformers (CT version) with x/5A
- M-Bus communication
- Nominal voltage: 230/400 V AC (3~)
- Operating voltage: 3 × 230/400 V ±20 %
- Housing: flame-retardant PC plastic
- International standard: EN 50470-1/3
- Accuracy class: B (1 % accuracy)
Electrical Data
- Base current (Ib): 1.5 A (CT version)
- Maximum rated current (Imax): 6 A (CT version)
- Operating current range: 0.4 % Ib to Imax
- Overcurrent withstand: 30 × Imax for 0.01 s
- Operating frequency: 45–60 Hz
- Power consumption: ≤2 W/phase or ≤10 VA/phase (active – reactive)
Insulation Strength
- AC withstand voltage: 4 kV for 1 minute
- Impulse withstand voltage: 6 kV, 1.2 μs waveform
- Protection class: II
Pulse Outputs
- Test output via red LED: 10,000 pulses/kWh
- Pulse rates: 10,000 / 2,000 / 1,000 / 100 / 10 / 1 / 0.1 / 0.01 pulses/kWh
-
Pulse width at 1,000 / 2,000 / 10,000 pulses:
- 0–4,999 W: 40 ms
- 5,000–9,999 W: 20 ms
- 10,000–19,999 W: 10 ms
- 20,000–39,999 W: 5 ms
- >40,000 W: 2.5 ms
-
Pulse width at 100 pulses:
- <50,000 W: 40 ms
- >50,000 W: 20 ms
- Other pulse rates: always 40 ms
Measurement Accuracy
- At 0.05 Ib, Cos φ = 1: ±1.5 %
- At 0.1 Ib, Cos φ = 0.5L: ±1.5 %
- At 0.1 Ib, Cos φ = 0.8C: ±1.5 %
- At 0.1 Ib to Imax, Cos φ = 1: ±1.0 %
- At 0.2 Ib to Imax, Cos φ = 0.5L: ±1.0 %
- At 0.2 Ib to Imax, Cos φ = 0.8C: ±1.0 %
Data Storage
- Data retention for more than 10 years without power supply
M-Bus Communication
- Bus type: M-Bus
- Baud rates: 300 / 600 / 1,200 / 2,400 / 4,800 / 9,600 baud
- Default baud rate: 2,400 baud
- Range: ≤1,000 m
- Downlink: voltage modulation from master to slave
- Uplink: current modulation from slave to master
- Cable: JYSTY (n × 2 × 0.8)
- Protocol: EN 13757-3
- Unit loads: ±2
- Maximum number of meters: 64 per bus*
Infrared Interface
- Infrared wavelength: 900–1,000 nm
- Communication distance: direct contact
- Protocol: IEC 62056-21:2002 (IEC1107)
Environmental Conditions
- Permitted operating humidity: ≤75 %
- Permitted storage humidity: ≤95 %
- Operating temperature, DC version: -40 to +70 °C
- Operating temperature, CT version: -25 to +70 °C
- Protection rating: IP51
Connection Data
-
Maximum conductor cross-section for power connections:
- 25 mm² for flexible conductors
- 35 mm² for solid copper conductors
Dimensions & Weight
- Height without protective cover: 92.4 mm
- Height: 141 mm
- Width: 70 mm
- Depth: 63 mm
- Weight: 0.39 kg net
Additional Data
- Protection against the ingress of dust and water: IP51
- Insulated-enclosed meter with protection class II
- *The maximum number of meters per bus depends on the converter used, the baud rate, and the installation conditions. The maximum possible number of meters is reduced at higher baud rates.