€41.40
AKCP Current Transformers - Professional Measurement Technology for Industrial Applications
Revolutionary Split-Core Current Transformers for Easy Installation
AKCP current transformers revolutionize the way current monitoring is implemented in industrial and commercial facilities. These innovative split-core current transformers are specially designed for simple, fast, safe, and hassle-free installation, enabling seamless connection between monitoring systems and existing power supply installations.
Innovative Split-Core Technology Without Operational Interruption
The decisive advantage of AKCP clip-on current transformers lies in their unique split-core design. These measurement transformers can be installed without disconnecting cables or busbars. While conventional current transformers typically require interrupting the primary circuit to pass cables or busbars through the transformer core or connect to the primary terminals, the AKCP transformer core can simply be opened, installed, and connected—all without any power supply interruption.
Versatile Application Areas in Measurement Technology
Current measurement technology with AKCP products covers a wide range of industrial requirements:
Overcurrent Detection and Protection Functions
The precise measurement transformers reliably detect overcurrents, providing crucial protection for electrical systems. This function is especially important in critical industrial applications, where undetected overloads can lead to costly downtime.
Ground Fault Detection for Maximum Safety
Current monitoring also includes ground fault detection, which is an essential safety aspect in electrical installations. This function helps prevent fires and other hazardous situations.
Precise Energy Measurement and Monitoring
For energy monitoring, AKCP current transformers offer highly accurate measurement essential for billing purposes and optimizing energy consumption. Integration into analog-to-digital circuits enables modern digital data processing.
Building and Facility Management
In the field of building and facility management, these measurement transformers enable continuous current monitoring, contributing to optimized operating costs and preventive maintenance.
Technical Excellence and Practical Benefits
Compact Design for Easy Mounting
The compact size of the AKCP split-core current transformers allows easy mounting even in tight spaces. The thoughtful design takes into account the practical requirements of modern switchgear.
Generous Opening for Versatile Applications
The wide inner window of the clip-on current transformers allows clamping of large cables or busbars. This flexibility makes them suitable for a variety of installation scenarios.
Comprehensive Size Range
The broad range of available sizes ensures that a suitable current transformer is available for virtually any existing installation. From small distributions to large industrial plants, AKCP offers the right solution.
High Accuracy and Reliability
The measurement technology of AKCP current transformers is characterized by exceptional precision and long-term reliability. These features are essential for professional current measurement technology.
Product Variants for Different Requirements
CTXXXX/5A Series for High-Power Applications
- The CTXXXX/5A series includes current transformers for primary currents from 100A to 5000A with a standardized 5A secondary current. These current transformers comply with international standards (IEC44-1, BS7626) and offer accuracy classes from 0.5 to 3.0. With a maximum voltage of 0.72/3kV and frequencies of 50/60Hz, they are suitable for most industrial applications.
CTXXX/5V Series for Direct Analog Inputs
- The CTXXX/5V split-core current transformers provide a 0-5 VDC output and are ideal for applications that do not require full power monitoring. These clip-on current transformers can be connected directly to A2D inputs of SPX+ or Wireless A2D adapters. With current ranges from 5A to 500A and a constant accuracy of 2% of full scale, they offer a cost-effective solution for energy monitoring.
Integration into Modern Monitoring Systems
AKCP current transformers are seamlessly integrated into the AKCP ecosystems and connect to power meters compatible with securityProbe and sensorProbe+ platforms. This integration enables comprehensive current monitoring with configurable parameters for monitoring and alerting based on various measurement factors.
The user-friendly interface allows setting specific parameters for current measurement technology and configuring different alert scenarios. This makes the systems especially valuable for critical infrastructures where reliable current monitoring is essential.
Time and Cost Savings through Innovative Technology
AKCP measurement transformers save both time and installation costs while offering a higher level of safety during work. The easy installation without operational interruption significantly reduces downtime and minimizes risk for installation technicians. These advantages make AKCP current transformers the first choice for professional measurement technology in demanding industrial environments.
Electrical Properties:
- Primary current range: 100A - 5000A
- Secondary current: 5A, 1A
- Maximum voltage: 0.72/3kV
- Frequency: 50/60Hz
- Rated burden: 1VA - 30VA
- Accuracy class: 0.5 / 1.0 / 3.0
- Short-time thermal current: 1th = 100 x ln
- Rated safety factor: FS < 5
Standards and Approvals:
- Standard approval: IEC44-1, BS7626
Available Models with Dimensions:
- DP-23: 20x30x51x89x111mm, Weight: 0.75 kg
- DP-58: 50x80x78x114x145mm, Weight: 0.90 kg
- DP-88: 80x80x108x144x145mm, Weight: 1.05 kg
- DP-812: 80x120x108x144x185mm, Weight: 1.25 kg
- DP-816: 80x160x120x184x245mm, Weight: 4.3 kg
CTXXX/5V Current Transformer (Split-Core)
Electrical Properties:
- Primary current range: 5A - 500A
- Output voltage: 1-5V DC (0-5V DC scaling)
- Maximum voltage: 720V
- Frequency: 50/60Hz
- Accuracy: 2% of full scale
- Connection cable: 2-wire cable to A2D input
Operating Environment:
- Temperature: -25°C to +60°C
- Humidity: 20% - 80% (non-condensing)
Available Current Classes:
- 5A - 50A
- 10A - 100A
- 100A - 300A
- 100A - 500A
Mechanical Properties:
- Split-core design for easy installation
- Opening angle: 180°
- Wide inner window for large cables or busbars
- Compact design for easy mounting
- Various sizes for existing installations
Applications:
- Overcurrent detection
- Ground fault detection
- Measurements
- Analog-digital circuits
- Building and facility management
Compatibility:
- Connection with Current Transformer Power Meter
- Compatible with securityProbe and sensorProbe+ platforms
- Direct connection to A2D input module on SPX+ or wireless A2D adapter
Manufacturer information:
AKCess Pro Ltd.
267/4 Soi Sichon, Sutthisan Rd., Samsen Nok
Huai Khwang Bangkok, 10310
Thailand
Email: sales@akcp.com
Responsible person:
Didactum® Security GmbH
Marsweg 17
48163 Münster
Deutschland
Fon: +49 - 2501 - 9 78 58 80
Email: info@didactum-security.de