€79.00
Current Measurement via Hall Effect Current Transformer Directly in the Monitoring System
The Didactum current transformer transmits the current values measured by a Hall effect current transformer to a Didactum monitoring system. This analog plug-and-play converter is connected to any analog port (A1 to A8) of a Didactum monitoring system or expansion unit and works with Hall effect current transformers with a 0–5V output signal and 12V DC power supply.
This article describes both available variants of the current transformer together: the AC variant for AC measurements and the DC variant for DC measurements. Both variants are identical in design, connection, and functionality, but differ in the type of external Hall effect current transformer they work with. The choice between AC and DC is made directly during the ordering process via the variant selection on this product page.
Individually configurable: AC or DC
The Didactum current transformer is already tailored during the ordering process to match the type of Hall effect current transformer already in use or planned.
Please note: The correct variant must be actively selected above the shopping cart button under “Select variant”. The AC variant works only together with an AC Hall effect current transformer, while the DC variant works only together with a DC Hall effect current transformer. An incorrect combination will not provide correct measurement values.
Select variant
AC
For monitoring AC current meters. Suitable for use with AC Hall effect current transformers for measuring alternating current.
DC
For monitoring DC current meters. Suitable for use with DC Hall effect current transformers for measuring direct current.
Both variants are identical in connection, structure, and function; details can be found in the “Structure” section below.
Current transformer connections
The current transformer has only a few, clearly separated connections for input, output, and the external current transformer.
Input: 3-pin terminal block
2.54 mm pitch. The external Hall effect current transformer is connected here using 3 wires (0–5V signal and 12V DC power supply).
Output: RJ11 6P4C
Connects the current transformer via RJ11 cable to an analog port (A1 to A8) of the Didactum monitoring system or a VT408 expansion unit.
The 12V DC power supply for the external Hall effect current transformer is provided by the Didactum monitoring system via the analog port and passed through by the current transformer to the current transformer sensor. A separate power supply for the current transformer sensor is not required.
Matching Hall effect current transformer required
The Didactum current transformer cannot be operated on its own. It absolutely requires an external Hall effect current transformer with 0–5V output and 12V DC supply, which performs the actual current measurement on the line.
HALL AC current transformer
Open AC current transformer for alternating current, available for measurement ranges from 5 to 50 A.
AC current transformer
AC current transformer for higher alternating currents, available for measurement ranges from 50 to 500 A.
DC current transformer
DC current transformer for direct current, available for measurement ranges from 50 to 500 A.
Alternatively, any other commercially available Hall effect current transformer with a suitable 0–5V output signal and 12V DC supply can also be used.
Install current transformer and sensor together
The current transformer sensor and Didactum current transformer are installed together.
Mount the current transformer sensor
Secure the Hall effect current transformer with screws and nuts. The line to be measured is guided through the aperture of the current transformer.
Connect to the monitoring system
Connect one end of the RJ11 cable to a free analog port (A1 to A8) of the Didactum monitoring system and the other end to the RJ11 port of the current transformer.
Wire the current transformer sensor
Connect the 3 wires to the Hall effect current transformer according to the wiring diagram using the 3-pin terminal block of the current transformer.
Safety instructions: Observe the applicable regulations for installation in the respective country as well as the relevant accident prevention regulations, in addition to internal company work, operating, and safety rules. The specified technical limits, especially the permissible ambient temperature range, must not be exceeded under any circumstances. Also check the maximum insulation voltage of the current transformer sensor and the maximum permissible cable diameter of the line to be measured before installation.
Full control over thresholds, trends, and automation
The current transformer integrates seamlessly into the Didactum web interface and delivers precise measurement values as well as actionable insights.
- Individual thresholds (Lower Critical, Lower Warning, Normal, Upper Warning, Upper Critical) per measurement point
- Logic schemes for automated actions when limit values are exceeded, e.g. in case of overload
- Clear, individually configurable dashboard
- Graphical trend display and continuous logging of measurement values
- Notifications via email, SMS, SNMP trap, and other channels
Areas of application for the current transformer
- Monitor circuits and outgoing feeders in electrical distribution boards to detect overloads
- Monitor power consumption of critical IT and facility equipment in the data center
- Measure generator load and detect over- or underload
- Monitor input and output current of UPS systems to assess backup performance
- Monitor motors, pumps, compressors, and production machines for load changes
- Record charging and discharging currents of battery banks and energy storage systems
- Check the power yield of solar inverters and other renewable energy systems
- Detect wear or defects early based on changed current consumption
What is included in the package
Please check the contents upon receipt for completeness and report any missing or damaged parts to your supplier immediately. The external Hall effect current transformer (AC or DC) is not included in this scope of delivery and must be ordered separately.
- Didactum current transformer (AC or DC, depending on the ordering option)1 piece
- RJ11 cable 6P4C, 2 m1 piece
- 3-pin terminal block, 2.54 mm1 piece
- 3-pin terminal block, 3.81 mm1 piece
- 3-wire connection cable, 2 m1 piece
- Screw B4.2 x 16 mm1 piece
- Self-adhesive label1 piece
Why this current transformer is the right choice
High accuracy
1% measurement accuracy in signal transmission from the current transformer sensor.
AC and DC available
Select the matching variant for alternating or direct current measurement.
Plug and play
Automatic detection at the analog port, no manual setup required.
No separate power supply
The 12V supply for the current transformer sensor is provided directly via the analog port.
Compact
Small form factor (80 × 19 × 20 mm), desktop or wall mounting.
Long range
Up to 50 m distance to the monitoring system or expansion unit.
Expandable
Add additional current transformers easily via the VT408 expansion unit.
Made in EU
Developed and manufactured in the European Union.
Frequently asked questions
What is the difference between the AC and DC variants?
Both variants are identical in connection and function. The AC variant is intended for use with AC Hall effect current transformers for AC measurement, while the DC variant is intended for use with DC Hall effect current transformers for DC measurement. The correct variant is selected during ordering via the options menu.
Can I use the AC variant with a DC current transformer sensor?
No. The AC variant works only with AC Hall effect current transformers, and the DC variant works only with DC Hall effect current transformers. An incorrect combination will not provide correct measurement values.
Is the external Hall effect current transformer included in the package?
No. The Didactum current transformer absolutely requires an external Hall effect current transformer with a 0–5V output and 12V DC supply, which must be ordered separately.
How is the current transformer connected?
The current transformer is connected via RJ11 cable to any analog port (A1 to A8) of the Didactum monitoring system. The external Hall effect current transformer is connected via a 3-wire cable to the 3-pin terminal block of the current transformer.
Does the current transformer sensor need its own power supply?
No. The 12V DC supply for the current transformer sensor is provided by the Didactum monitoring system via the analog port and passed through by the current transformer.
Can the current transformer be operated independently without a monitoring system?
No. The current transformer itself provides no display or analysis and must always be used together with a Didactum or Vutlan monitoring system and a suitable external Hall effect current transformer.
Questions about the Didactum current transformer?
Our support team in Germany will advise you free of charge on selection, installation, and configuration.
Didactum AC/DC Current Transformer
General Data
- AC/DC current transformer for measuring alternating and direct current
- Hall-effect current sensor for contactless current measurement
- Analog plug-and-play sensor
- Transmitter/converter for integration with Didactum and Vutlan monitoring systems
- Made in the EU
Technical Data
- Measurement principle: Hall effect
- Sensor type: Analog
- Accuracy: ±1%
- Power consumption: approx. 1 mW
Connections
- Input: 3-pin current terminal block (2.54 mm pitch)
- Output: RJ11 (6P4C)
- Maximum cable length to the monitoring system or VT408 expansion module: 50 m
- Maximum distance when powered via the analog port: up to 225 m
Compatibility
- Didactum monitoring systems with analog port
- Vutlan monitoring systems
- 8-port analog port expansion module
Power Supply
- Powered via the analog port of the Didactum/Vutlan monitoring system or the VT408 expansion module
- No separate power supply required
Mounting
- Tabletop mounting
- Wall mounting
Environmental Conditions
- Operating temperature: -10 °C to +80 °C
- Relative humidity: 0–95% (non-condensing)
Dimensions & Weight
- Dimensions: 80 × 19 × 20 mm (L × W × H)
- Weight: approx. 20 g
Scope of Delivery
- Didactum AC/DC current transformer
Manufacturer information:
Didactum® Security GmbH
Im Mühlenfeld 4
48163 Münster
Deutschland
Fon:
(+49) 250 19 71 63 54 / (+49) 171 33 11 577
Email: info@didactum-security.de