€534.00
ENVIROMUX 2D: Compact Security for Small Server Rooms
In small and medium-sized businesses, every server room – whether in a cabinet, basement, or co-location – is a critical point.
A temperature rise due to a faulty air conditioner, a water leak from a pipe, or an unnoticed power outage can destroy expensive hardware within minutes and bring business operations to a standstill.
This is exactly where NTI’s ENVIROMUX 2D comes in: a compact yet powerful monitoring system specifically designed for smaller IT environments. It reliably monitors temperature, humidity, and the presence of liquids – and immediately alerts you when something goes wrong. Whether by e-mail, SMS, web alarm, SNMP trap, or voice call: you’ll always stay informed, even when you’re off-site. With only two external sensor ports, five digital inputs, and one relay output, it’s intentionally streamlined yet still expandable – ideal for server cabinets, small data centers, or remote locations.
Imagine you’re running an online shop backend in a 19-inch cabinet at your office. Suddenly, the temperature rises above 30°C because the ventilation fails. The ENVIROMUX 2D immediately detects this: the red LED flashes, an SMS reaches your IT administrator, and the relay automatically switches on an additional fan. The problem is solved within minutes – without data loss, downtime, or costly repairs.
This scenario is not hypothetical: a retail customer recently detected a water leak caused by a leaking roof using the ENVIROMUX 2D. The sensor triggered an alarm, the siren went off, and the team was able to secure the servers in time. Such cases demonstrate that proactive monitoring is essential even in small environments – and the ENVIROMUX 2D provides exactly that: easy installation, reliable operation, and immediate responsiveness.
What makes the ENVIROMUX 2D particularly attractive is its flexibility combined with minimal space requirements. It runs on a stable Linux system, supports DHCP or static IP, and can be configured from anywhere via a user-friendly web interface – on PC, tablet, or smartphone.
Installation is simple: zero-RU with mounting flanges, optional 1RU rackmount (front or rear), or DIN rail. With optional PoE power supply, dual redundancy, or 24V/48V DC, even the power plug becomes unnecessary. And thanks to the optional internal battery, monitoring continues during power outages – including a notification when power is restored. Whether in a tax advisor’s server cabinet, a training provider’s technical room, or a POP site: the ENVIROMUX 2D fits everywhere and protects where it matters most.
After these core advantages, let’s look at its practical applications and functions. The ENVIROMUX 2D is purpose-built for efficiency – ideal for environments where space and budget are limited. Here are the key features at a glance:
- Compact sensor design: 2 external configurable sensors + 5 digital inputs. Example: a temperature and a water sensor in a server cabinet detect overheating and leaks – the relay activates a pump or opens a window in case of an alarm.
- Multiple alert channels: E-mail, SMS (via USB modem or E-mail-to-SMS), web alarm, SNMP traps, voice calls. In a co-location rack, a provider recently detected rising humidity – an SMS reached the technician at night, who acted immediately to prevent condensation on cables.
- IP expansion: Up to 8 remote temperature/humidity sensors (E-MICRO), 4 1-Wire sensors (E-1W), or 2 remote power switches (PWR-RMT). This allows you to monitor remote rooms – for example, a storage room with backup servers – through a single system.
- Ping monitoring: Up to 64 network devices (routers, switches) can be pinged. If a device fails, a warning is triggered immediately – ideal for small networks without expensive NMS software.
- Scalability: Cascade up to 5 units via Ethernet. One master device controls four slaves – all data in one interface. Perfect for centrally monitoring multiple locations.
The ENVIROMUX 2D’s application areas are diverse and practical. In small server cabinets of SMEs, it replaces costly enterprise solutions: a law firm in Berlin uses it to protect a 24/7 file server – during a power outage, it automatically switches to UPS and sends an SMS notification. In co-location environments, it secures dedicated racks: a hosting provider combines it with IP cameras – when intrusion is detected, the sensor triggers a video recording and sends it via e-mail.
For remote locations or branches, the wireless option is invaluable: with a WLAN router and range extender, the ENVIROMUX 2D becomes wireless – a craft business monitors its workshop server without laying cables. It also performs reliably in technical rooms with high temperatures (up to 75°C in the industrial version) – for example, in production halls or control rooms.
- Example: Medical practice – Temperature in the medication server room increases due to air conditioner failure. ENVIROMUX 2D sends an e-mail alert, relay starts emergency ventilation: medicines stay cool, practice stays online.
- Example: School IT room – Water sensor detects leakage under the floor. SMS to caretaker, relay switches off water pump: no computer damage, classes continue smoothly.
- Example: Branch network – Router at a branch site fails. Ping alarm via SNMP to the headquarters, technician reboots remotely via SSH command: no on-site visit needed.
Integration into existing systems is straightforward: connect it to Nagios or Zabbix for graphical dashboards, or use MRTG for long-term trend tracking. The optional self-hosted management software can centrally manage up to 3,000 units – with group configuration and push updates. The web interface is mobile-optimized: on your smartphone, you can view all sensors at a glance, including alarm status.
On the device itself, LEDs provide local control: green = all good, red = alarm. With “Restore Defaults” and “System Reset”, you always maintain full control. Configuration via USB, Telnet, or SSH is fully secure thanks to AES-256 encryption and LDAP authentication. Up to 16 users can access the system simultaneously, each with individual rights.
- Application: Hospitality – Cooling server for order systems: temperature rise detected, SMS to head chef, relay activates backup cooling – no loss of revenue.
- Application: Craft enterprises – Workshop server: intrusion sensor triggers camera snapshot, e-mail with image sent to owner – evidence secured.
- Example: Energy provider – Transformer station: power failure detected, battery backup responds, maintenance logs generated – high availability ensured.
The ENVIROMUX 2D is the smart solution for anyone seeking professional monitoring – without complexity or high costs. With 50 configurable events and 20 smart alerts, you can respond flexibly: for example, combine “temperature > 28°C” with “no ping from switch” for targeted escalation. The logs store up to 1,724 records – perfect for audits or traceability.
The ENVIROMUX 2D reliably, flexibly, and cost-effectively protects small IT environments. It minimizes risks, maximizes availability, and saves stress – the ideal choice for SMEs, branch offices, and decentralized sites.
Available Versions:
- ENVIROMUX-2D
Environmental monitoring system for small businesses (standard model) - ENVIROMUX-2DB
Environmental monitoring system for small businesses, with backup power supply (battery) - ENVIROMUX-2D-D
Environmental monitoring system for small businesses, including DIN mounting kit - ENVIROMUX-2DB-D
Environmental monitoring system for small businesses, with backup power and DIN mounting kit - ENVIROMUX-2D-24V
Environmental monitoring system for small businesses, 24 V DC power supply - ENVIROMUX-2D-48V
Environmental monitoring system for small businesses, 48 V DC power supply - ENVIROMUX-2D-IND
Industrial environmental monitoring system for small businesses, suitable for high-temperature environments - ENVIROMUX-2D-POE
Environmental monitoring system for small businesses, Power over Ethernet (PoE)
YouTube
- e-2d:
Basic Unit - e-2db:
Basic Unit with Emergency Power Supply (Backup Battery) - e-2d-d:
Basic Unit including DIN Mounting Kit - e-2db-d:
Basic Unit with Emergency Power Supply and DIN Mounting Kit - e-2d-24v:
Basic Unit with 24 V DC Power Supply - e-2d-48v:
Basic Unit with 48 V DC Power Supply - e-2d-ind:
Basic Unit suitable for high-temperature environments - e-2d-poe:
Basic Unit with Power over Ethernet (PoE)
Technical Specifications
- RJ45 Sensor Ports
- 2x RJ45 jacks for NTI temperature, humidity, liquid, smoke, glass break, vibration, and motion sensors
- Two alert levels: non-critical and critical
- Power supply: +12VDC, 100mA per port
- Digital Inputs (Dry Contact)
- 5 screw terminal pairs for dry contacts and liquid sensor
- Dry contact
- Output voltage: +5VDC (current-limited to 10mA)
- Maximum resistance to close contact: 300 kΩ
- Relay Output
- 1 screw terminal pair with isolated relay contacts
- Normally open / normally closed
- Maximum switching load: 1A at 125VAC or 30VDC
- USB Ports
- 2x USB Type-A (for modem or data download to USB stick)
- 1x USB Type-B (for PC console connection)
- Ethernet Port
- 1x RJ45 jack
- 10/100 Base-T Ethernet, full/half-duplex
- AUX Power Output
- 1 screw terminal pair
- +12VDC, 500mA
- Optional Backup Battery
- Rechargeable sealed lithium battery
- Powers the device for up to 2 hours during power failure
- Protocols
- HTTP/HTTPS, SNMP V1/V2c/V3, SMTP, TCP/IP, Syslog, SNTP, DHCP, SSHv2, SSLv3, TLS v1.2, LDAPv3, XOAUTH2, AES 256-bit, 3DES, Blowfish, RSA, EDH-RSA, Arcfour, IPv6, WAP 2.0, RADIUS
- XOAUTH2 support for secure e-mail authentication (e.g. Gmail)
- SNMP-compatible, queryable via SNMP
- Operation/configuration via Web (HTTP/HTTPS), Telnet, SSH, or USB interface
- REST API (JSON output), e-mail, Syslog, SMS notifications
- Browser and System Compatibility
- Browsers: Internet Explorer 6+, Firefox 1.5+, Chrome, Safari (Mac 1.3+/PC 3.0+)
- Systems: Windows 7/8/10/11, Windows Server 2008–2022, Solaris, Linux, FreeBSD, macOS 10–12
- Network Functions
- DHCP support for automatic IP addressing
- SNMP traps, e-mail notifications (up to 17 recipients)
- Event log accessible via web
- Dimensions (W x D x H)
- E-2D, E-2DB, E-2D-IND, E-2D-POE: 5.82 x 3 x 1.75 in (148 x 76 x 44 mm)
- E-2D-D, E-2DB-D: 5.82 x 3.3 x 1.75 in (148 x 84 x 44 mm)
- E-2D-24V, E-2D-48V: 10.63 x 3.11 x 1.75 in (270 x 79 x 44 mm)
- Optional 1RU rackmount kit available
- Mounting possible with front or rear sensor ports
- Weight
- E-2D: 1.0 lb (0.45 kg)
- Power Supply
- Dual DC power inputs (automatic failover switching)
- Input: 100–240 VAC, 50/60 Hz via AC adapter
- Includes 9VDC/3A AC adapter (second optional)
- Output voltage: 9–12 VDC
- Power consumption: 10 W
- Optional PoE support: IEEE 802.3af, 802.3at (no proprietary standards such as Cisco Discovery Protocol)
- Optional 24VDC supply: 9–36 VDC (nominal 24 VDC)
- Optional 48VDC supply: 18–72 VDC (nominal 48 VDC, with DC-DC converter PWR-48V-12V1-6A)
- MTBF
- E-2D: 229,580 hours
- E-2DB: 230,693 hours
- Environmental Conditions
- Operating temperature:
- E-2D: 32–140°F (0–60°C)
- E-2D-IND: -4–167°F (-20–75°C)
- Storage temperature: -22–140°F (-30–60°C)
- Humidity: 5–90% (non-condensing)
- Operating temperature:
- Certifications: CE, RoHS, EN51055, EN50121-3-2
- Warranty: 2 years
Manufacturer Information:
Network Technologies Inc
1275 Danner Dr.
Aurora, OH 44202
USA
Phone: 330-562-7070
Email: sales@ntigo.com
Responsible person:
Didactum® Security GmbH
Marsweg 17
48163 Münster
Deutschland
Fon: +49 - 2501 - 9 78 58 80
Email: info@didactum-security.de