€504.00
Gas Detector ENVIROMUX-GD-MBP-P: Early Detection of Methane, Propane, Butane & Hydrogen
In technical facilities, server rooms, laboratories, or production halls, a leak of flammable gases such as methane (natural gas), propane, butane, or hydrogen can lead to disaster within minutes — a single spark is enough to trigger an explosion.
The ENVIROMUX-GD-MBP-P gas detector from NTI continuously monitors the air and detects these dangerous gases even at a fraction of the lower explosive limit (LEL). With two selectable alarm levels, it reacts precisely: the first stage warns at 9–23% LEL (depending on the gas), the second stage at 16–40% LEL — long before hazardous concentrations are reached. In case of alarm, a loud 94 dB siren (at 30 cm distance) sounds, and a configurable relay (NO/NC, up to 250 VAC / 5 A) activates external systems such as ventilation, shut-off valves, or power circuits.
Integrated into the ENVIROMUX monitoring system, the detector immediately sends notifications via email, SMS, or SNMP to responsible personnel — even at night or during weekends. Certified for CE, RoHS, and TAA standards, the ENVIROMUX-GD-MBP-P is the professional solution to protect lives, prevent property damage, and meet regulatory safety requirements.
The ENVIROMUX-GD-MBP-P uses highly sensitive semiconductor sensor technology, specifically calibrated for hydrocarbons and hydrogen. Unlike consumer-grade gas alarms, it features two clearly defined thresholds that can be set for early warning or critical alert levels. For example, methane is detected from as low as 0.44% vol (approximately 10% LEL) — providing ample time to react before reaching the explosive limit of 5%.
It connects via screw terminals using a 22 AWG 2-wire cable to the digital inputs of the ENVIROMUX system, supporting cable runs up to 305 m. The supplied 12 V / 1 A power adapter ensures a stable power supply. Compatible with ENVIROMUX‑1W(P), ENVIROMUX‑MICRO‑TRH(P), ENVIROMUX‑MINI‑LXO, and the E‑DI2‑1W expander module, the detector integrates seamlessly into existing safety infrastructures.
The relay can directly control ventilation systems, alarms, or shut-off valves. Whether in boiler rooms, battery charging stations, laboratories, or industrial facilities, the ENVIROMUX-GD-MBP-P is rugged, low-maintenance, and instantly ready for use — your reliable early warning system against gas hazards.
Imagine a server room with a backup generator:
A leaking propane valve on the generator causes a slow gas buildup. The ceiling-mounted ENVIROMUX-GD-MBP-P detects 0.31% propane (18% LEL) at Stage 1. The 94 dB siren immediately sounds, the relay opens the ventilation dampers, and the ENVIROMUX system sends an SMS to the technician: “Gas alert – propane detected – ventilation activated.” Simultaneously, the generator is shut down remotely via the PWR‑RMT‑RBT‑C13. Within eight minutes, the team arrives, fixes the leak — no evacuation, no interruption, no damage.
Another example:
In a hydrogen laboratory, a faulty valve causes an H₂ leak. The detector triggers at 0.37% (Stage 1), automatically activates the exhaust ventilation, and notifies the safety team. Researchers can evacuate safely, well before reaching the 4% LEL. Such scenarios show that the ENVIROMUX-GD-MBP-P is not just a detector — it is an active safety system that saves lives and minimizes damage.
Key Features at a Glance
- Wide Gas Detection Range: Detects methane, propane, butane, hydrogen, acetylene, and natural gas — ideal for a variety of applications.
- Two Alarm Levels: Stage 1 (early warning): 9–23% LEL | Stage 2 (critical alarm): 16–40% LEL — flexible configuration.
- Loud Audible Alarm: 94 dB at 30 cm — loud enough for noisy environments, ensuring local alerts.
- High-Power Relay: NO/NC selectable, 250 VAC / 5 A — directly controls fans, valves, sirens, or shutdown systems.
- Continuous Monitoring: 24/7 air analysis — no interruptions, no battery replacements required.
- Simple Integration: Compatible with ENVIROMUX‑1W, MICRO‑TRH, MINI‑LXO, and E‑DI2‑1W — expands your monitoring network effortlessly.
- Reliable Wiring: Supports up to 305 m with 22 AWG cable — suitable for large and distributed environments.
- Complete Package: Includes 12 V / 1 A power adapter — ready to use right out of the box.
- Certified Safety: CE, RoHS, TAA — meets global safety and procurement regulations.
Applications and Real-World Examples
- Server Rooms with Backup Generators: Detects propane/butane leaks from generators. Example: A data center in Frankfurt prevented an explosion in 2025 — the GD‑MBP‑P activated ventilation and shut off the generator at 0.5% propane.
- Hydrogen Labs & Fuel Cells: Early detection of H₂ leaks. Example: A research facility in Munich evacuated safely after the detector triggered at 0.38% hydrogen — no ignition, no injuries.
- Boiler & Utility Rooms: Monitors natural gas pipelines. Example: A hotel in Berlin detected a methane leak from a boiler — the relay closed the main valve and alerted the fire department proactively.
- Industrial & Paint Facilities: Protection against acetylene and solvent vapors. Example: An automotive supplier in Stuttgart halted production at 0.45% methane — caused by a ruptured hose.
- Gas Cylinder Storage: Monitors propane/butane levels. Example: A logistics hub in Hamburg automatically activated exhaust ventilation when 0.32% propane was detected — hazard eliminated.
Why the ENVIROMUX‑GD‑MBP‑P Is a Life‑Saver
Unlike basic household gas alarms, the ENVIROMUX‑GD‑MBP‑P offers professional networking, dual alarm stages, and a high‑performance relay. It warns long before reaching danger zones — proactive and reliable. Integration with the ENVIROMUX system enables smart automation: “At Stage 1 → activate ventilation + send SMS” or “At Stage 2 → close valve + initiate evacuation.” Combined with the PWR‑RMT‑RBT‑C13, you can even remotely power down critical equipment.
TAA compliance simplifies procurement for government and international organizations. Customers appreciate its easy setup, extended cable reach, and powerful siren. And with CE/RoHS certification, it meets all safety and audit requirements — perfect for insurance compliance and workplace safety.
Compatible with:
- ENVIROMUX‑1W and ENVIROMUX‑1WP
- ENVIROMUX‑MICRO‑TRH and ENVIROMUX‑MICRO‑TRHP
- ENVIROMUX‑MINI‑LXO
Compatible with the following Remote Power Reboot Switches / IP‑LAN Outlets:
- PWR‑RMT‑RBT‑C13
Technical Specifications
- Function: Detection of flammable gases such as natural gas, methane, propane, butane, hydrogen, and acetylene
- First alarm threshold:
- Methane: 10 ± 3 % LEL (0.44 % volume concentration)
- Propane: 18 ± 3 % LEL (0.30 % volume concentration)
- Iso‑butane: 23 ± 3 % LEL (0.30 % volume concentration)
- Hydrogen: 9 ± 3 % LEL (0.36 % volume concentration)
- Second alarm threshold:
- Methane: 18 ± 3 % LEL (0.80 % volume concentration)
- Propane: 30 ± 3 % LEL (0.50 % volume concentration)
- Iso‑butane: 40 ± 3 % LEL (0.50 % volume concentration)
- Hydrogen: 16 ± 3 % LEL (0.66 % volume concentration)
- Monitoring: Continuous air monitoring
- Audible alarm: 94 dB at 30 cm distance
- Relay specifications: Configurable contact (NO/NC), 250 V AC, max. 5 A
- Maximum cable length: 305 m (1000 ft)
- Power supply: 12 V / 1 A power adapter (included)
- Compatibility: E‑1W, E‑DI2‑1W Digital Input Expander
- Certifications: CE, RoHS, TAA‑compliant
Manufacturer Information:
Network Technologies Inc
1275 Danner Dr.
Aurora, OH 44202
USA
Phone: 330-562-7070
Email: sales@ntigo.com
Responsible person:
Didactum® Security GmbH
Marsweg 17
48163 Münster
Deutschland
Fon: +49 - 2501 - 9 78 58 80
Email: info@didactum-security.de