€202.40
AKCP Smoke Sensor SK00 - Professional Fire Protection for Critical Infrastructures
The SNMP-enabled Smoke Sensor SK00 from AKCP is specially designed for early fire detection in mission-critical environments. Server rooms, data centers, production sites, and warehouses can be completely destroyed by fire within minutes, leading to catastrophic economic and legal consequences.
Fire Risks in Critical Infrastructures
The causes of fires in IT infrastructures are diverse and often unpredictable. The most common fire causes include:
- Negligent or intentional arson
- Technical defects (faulty power supplies, server overheating)
- Lightning strikes and electrical surges
- Overheating of air conditioning and UPS systems
- Spontaneous combustion due to faulty wiring
- Short circuits and electrical faults
Since not every company has mirrored server rooms or redundant infrastructures, besides significant economic damage due to costly downtimes, legal consequences due to data loss or compliance violations may also arise.
Technical Specifications of the AKCP SK00 Smoke Sensor
The SK00 smoke detector is based on a photoelectric detection system and meets the highest safety standards:
Sensor Features:
- Sensor type: Photoelectric smoke detector
- Detection range: Smoke / No smoke (binary detection)
- Operating temperature: -20°C to 60°C (-4°F to 140°F)
- Alarm sound: 85dB at 3 meters distance
- Dimensions: Diameter 130mm, Height 51mm
- Power consumption: 290 mW (58mA)
Safety Features:
- Full function test button
- Automatic alarm reset
- Insect-resistant sensing chamber
- Low profile for optimal ceiling mounting
- Complies with UL 217 standard and BS 5839 pt 6 Grade F
- LED status indicator and strobe light on smoke detection
Network Integration and SNMP Monitoring
As an IP-capable smoke sensor, the SK00 integrates seamlessly into existing network monitoring systems. Connection is via standard RJ45 port with Cat5/Cat6 cable to AKCP sensorProbe or securityProbe base units.
The sensor has a unique OID (Object Identifier) and can be queried directly over the network via SNMP commands. This allows seamless integration into professional Network Management Systems such as Nagios, HP OpenView, WhatsUp Gold, or OpenNMS.
Alarm and Notification Systems
In the intuitive web GUI of AKCP sensorProbe and securityProbe devices, you can comfortably configure the smoke sensor and set various alarm options:
Notification types:
- Email alert: To up to 6 recipients simultaneously
- SMS notification: Via 3rd-party gateway
- SNMP trap: Direct forwarding to monitoring systems
- Integration: Into fire alarm systems and control panels
The disconnect alarm provides additional security by automatically notifying you if contact to the sensor is interrupted due to tampering or sabotage. This feature is especially important for monitoring remote sites and branch offices.
Installation and Mounting Options
For optimal smoke detection, the SK00 should be mounted on the ceiling. The sensor is suitable for room monitoring as well as direct installation in server and equipment cabinets.
Mounting options:
- Ceiling mount: Optimal smoke detection through rising smoke gases
- Cabinet installation: Direct protection of critical IT hardware
- Screw mounting: Secure fastening with supplied hardware
Scalable Monitoring Solutions
The AKCP smoke sensor offers flexible expansion options for infrastructures of different sizes:
Cabling and range:
- Daisy chaining: Up to 10 smoke sensors per port
- Sensor spacing: Maximum 30 meters between chained sensors
- Potential-free contact: Connection of multiple sensors via dry contact inputs
This configuration is ideal for fire monitoring of large infrastructures such as data centers, production halls, or multi-site environments.
Protecting Your IT Infrastructure
A fire in mission-critical areas can have existential consequences for small and medium-sized businesses. AKCP's network-based remote monitoring solutions provide professional protection even for remote branches and sites.
Advantages of AKCP fire monitoring:
- Early detection: Detection at the early stages of fire
- 24/7 monitoring: Continuous sensor surveillance
- Central management: All sites in one user interface
- Mapping functions: Immediate localization of critical alarms
- Redundant alerting: Multiple notification channels
Integration into Existing Security Systems
The SK00 can operate in parallel with existing fire alarm systems. Thanks to dual connection options (intelligent sensor port and dry contact), both AKCP monitoring and conventional fire alarm control panels can be controlled.
System integration:
- Parallel operation: With existing fire alarm systems
- SNMP integration: Into professional monitoring systems
- Web-based management: Central configuration and monitoring
- Alarm escalation: Stepwise notification by priority
Maintenance and Reliability
The AKCP SK00 smoke sensor is designed for low-maintenance continuous operation. The internal battery ensures continuous monitoring even during power outages. The autosense feature with disconnect alarm provides automatic fault detection for cable breaks or sensor failures.
Reliability features:
- Internal emergency power supply: Battery backup for power failures
- Automatic self-tests: Continuous function checks
- Insect resistance: Maintenance-free sensing chamber
- Long-term stability: Years of maintenance-free operation
The combination of professional hardware, intelligent network integration, and flexible alerting options makes the AKCP SK00 the ideal solution for fire protection of critical IT infrastructures. Whether single-site or multi-site environment – the SK00 smoke sensor provides reliable protection against fire damage and its catastrophic consequences.
YouTube
Datasheet 1
- Measurement Range: Smoke or no smoke
- Sensor Type: Photoelectric smoke detector
- Output Type: Open/closed contact switch
- Special Features:
- Loud 85 dB alarm at 3 meters
- Full-function test button
- Automatic alarm reset
- Insect-resistant detection chamber
- Low-profile design for ceiling mounting
- Compliant with UL 217 standard
- Suitable for installations per BS 5839 Part 6, Grade F
- Measurement Rate: Multiple readings per second
- Status Indicators:
- Status LED
- Strobe light when smoke is detected
- Operating Temperature:
- –20 °C to +60 °C
- 4 °F to 140 °F
- Interface: RJ-45 jack via UTP Cat 5 cable
- Communications Cable:
- Standard CAT5/6 LAN cable
- Maximum length: 150 meters (500 feet)
- Power Source:
- Interface module powered by base unit
- Internal battery in the smoke detector
- Full autosense including disconnect alarm
- Power Consumption: Typically 290 mW, 58 mA
- Dimensions:
- Diameter: 130 mm
- Height: 51 mm
- Mounting: Screw mounting
- Sensor Count: 1
Matching AKCP monitoring device
Matching extension units
Manufacturer information:
AKCess Pro Ltd.
267/4 Soi Sichon, Sutthisan Rd., Samsen Nok
Huai Khwang Bangkok, 10310
Thailand
Email: sales@akcp.com
Responsible person:
Didactum® Security GmbH
Marsweg 17
48163 Münster
Deutschland
Fon: +49 - 2501 - 9 78 58 80
Email: info@didactum-security.de