Precise Airflow Monitoring for Server Rooms and Industry
The Didactum Airflow Sensor is a key component for professional airflow monitoring in server rooms, data centers, and other critical business areas. In modern IT and industrial environments, reliable airflow monitoring is essential to ensure operational safety, energy efficiency, and the service life of technical equipment.
Server rooms and data centers form the backbone of a company's digital infrastructure. They house high-performance servers, network switches, storage systems, and other critical devices that generate significant heat during operation. Constant and effective cooling is therefore essential to prevent overheating, failures, and data loss. Airflow monitoring with the Didactum Airflow Sensor ensures that air conditioning systems, HVAC systems, and fans always operate optimally and that airflow is sufficient at all relevant points.
Even small disturbances in airflow—such as blocked ventilation grilles, defective fans, or incorrectly adjusted air conditioning systems—can lead to dangerous temperature increases. The Didactum Airflow Sensor detects such problems at an early stage by measuring airflow speed precisely in the range of 0 to 3 m/s. If a critical value is undershot, the Didactum Monitoring System can automatically trigger an alarm, increase the air conditioning output, or notify IT staff.
Airflow Sensor Design
The sensor is intentionally designed in two parts to allow optimal placement directly in the airflow.
The actual measuring head is located at the end of a slim arm approximately 60 cm long (overall dimensions approx. 600 × 18 × 18 mm, approx. 106 g) and is connected via an RJ9 connector (4P4C) to a small 3-pin JST connection unit. This connection unit is in turn connected to an analog sensor port (A1…A8) of the Didactum Monitoring System via a 2-meter RJ11/RJ12 cable (6P4C, standard telephone cable). This two-part design allows the measuring head itself to be placed flexibly and precisely in the airflow, while the connection unit can be conveniently mounted outside the airflow—for example, in a rack or control cabinet. The scope of delivery also includes a bendable mounting bracket made of 0.8 mm steel sheet, which can be individually adapted to the respective rack or cabinet geometry using pliers or side cutters.
How the Sensor Measures Airflow
The Didactum Airflow Sensor continuously measures airflow speed in the range of 0 to 3 m/s and delivers reliable measured values in near real time with a response time of only 0.1 seconds. Sensitivity is preset at the factory, so no manual calibration is required. The sensor is connected via the supplied cable to any analog port (A1…A8) of the Didactum Monitoring Unit. Thanks to plug-and-play functionality, the sensor is automatically detected and appears immediately in the “System Tree” of the web interface.
Installation and Placement
Installing the Didactum Airflow Sensor is particularly easy and flexible thanks to its well-designed two-part construction.
- Connect the measuring head to the 3-pin JST connection unit via the RJ9 connector (4P4C).
- Connect one end of the supplied RJ11/RJ12 cable to the connection unit and the other end to a free analog port (A1…A8) of the monitoring system.
- If necessary, bend the supplied mounting bracket with pliers or side cutters to match the rack or cabinet geometry.
- Position the measuring head as close as possible to the airflow source (e.g., air conditioner, fan) — the optimal installation distance is best determined by trial and error, as hardly any airflow can be measured at too great a distance.
- The sensor is automatically detected in the web interface and can be configured there with custom threshold values and alarm rules.
Safety note: The measuring head should be checked regularly for dust deposits and cleaned if necessary, as dust can impair measurement accuracy.
Scalability for Larger Installations
For larger monitoring systems or extensive facilities, the number of Airflow Sensors and the total cable length can be expanded using a Didactum Sensor Extension Unit. This also makes it possible to centrally monitor complex climate zones, large server rooms, or multiple floors. Configuration is conveniently carried out via the web-based Didactum Monitoring Interface, where individual threshold values, alarms (e.g., email, SMS, SNMP trap), and automatic control actions can be defined.
Monitoring Critical Business Areas
Airflow monitoring is important not only in server rooms, but also in many other sensitive areas.
Server Rooms & Data Centers
Ensures optimal cooling at racks, air outlets, and air conditioning systems.
Production & Industrial Facilities
Cooling of machines and control cabinets as well as monitoring of steam and dust extraction systems.
Laboratories & Clean Rooms
Compliance with hygiene and safety regulations through constant air circulation.
Warehouses & Logistics Centers
Uniform air circulation to prevent moisture damage and mold growth.
Office & Residential Buildings
Prevention of drafts, hot spots, or cold zones for a comfortable indoor climate.
HVAC System Optimization
Quick identification of fault sources and inefficient settings in ventilation systems.
Practical Application Examples
- HVAC monitoring: continuous measurement at server racks, air outlets, or air conditioning systems with automatic corrective action in the event of deviations.
- Production and industrial facilities: sufficient cooling of machines, control cabinets, and production lines to prevent overheating.
- Laboratories and clean rooms: compliance with required airflow values including automatic alarm notifications in the event of deviations.
- Comfort management: early detection and correction of drafts, hot spots, or cold zones in office and residential buildings.
- System performance optimization: rapid identification of maintenance needs or inefficient HVAC settings.
- Energy efficiency: demand-based control of ventilation and air conditioning systems, increasing ventilation only when actually needed.
What Is Included
Please check the scope of delivery for completeness upon receipt and report any missing or damaged parts to your supplier immediately.
- Didactum Airflow Sensor (measuring head + connection unit)1 piece
- RJ11/RJ12 connection cable, 2 m1 piece
- Mounting bracket for rack/cabinet installationincluded
Why the Airflow Sensor Is the Right Choice
Precise Measurement
Airflow monitoring in the range of 0 to 3 m/s with a 0.1 s response time.
Easy Installation
Plug-and-play thanks to the two-part design with flexible measuring head placement.
Factory Calibrated
Preconfigured sensitivity, no manual adjustment required.
Flexible Mounting
Bendable mounting bracket adapts to any rack or cabinet geometry.
Scalable
Expandable via the Didactum Sensor Extension Unit.
Versatile
IT, industry, laboratories, building services, and environmental control.
Energy Efficient
Targeted control of HVAC and ventilation systems saves costs.
Made in EU
Developed and manufactured in the European Union.
Frequently Asked Questions
What exactly does the Airflow Sensor measure?
The sensor measures airflow speed in the range of 0 to 3 m/s, for example near air conditioners, fans, or ventilation outlets, and provides reliable measured values in near real time with a response time of 0.1 seconds.
Why is the sensor made of two parts?
The actual measuring head is connected via an RJ9 cable to a small connection unit, which is then connected to the monitoring system via an RJ11/RJ12 cable. This two-part design allows the measuring head to be placed flexibly directly in the airflow while the connection unit can be mounted conveniently outside.
Where should the sensor be placed?
The measuring head should be installed as close as possible to the airflow source, such as directly at an air conditioner or fan. If the distance is too great, hardly any airflow can be measured; the optimal installation distance is therefore best determined by trial and error.
Do I need to adjust the sensor sensitivity?
No. Sensitivity is preset at the factory, so no manual calibration is required. The sensor is ready to use immediately after connection.
How is the mounting bracket adapted to my rack?
The supplied mounting bracket is made of 0.8 mm steel sheet and can be bent and trimmed individually with pliers or side cutters to fit the respective rack or cabinet geometry precisely.
What should I keep in mind during maintenance?
The measuring head should be checked regularly for dust deposits and cleaned if necessary, as dust can impair measurement accuracy.
Can I use multiple Airflow Sensors at the same time?
Yes. For larger monitoring systems or extensive facilities, the number of Airflow Sensors and the total cable length can be expanded with a Didactum Sensor Extension Unit, allowing complex climate zones or multiple floors to be centrally monitored.
Questions about the Airflow Sensor?
Our support team in Germany offers free advice on selection, installation, and configuration.
Didactum Airflow Sensor
Function
- Analog plug-and-play sensor for measuring airflow and wind speed
- Ideal for use in air conditioning systems, HVAC systems, fans, and ventilation systems
- Reliably monitors air circulation to ensure optimal operating conditions
- Direct connection to analog ports (A1...A8) of Didactum monitoring systems
- Expandable via extension unit
Measurement Range
- Air velocity: 0 to 3 m/s
- Measured variable: airflow / wind speed
- Response time: 0.1 seconds
- Preconfigured sensitivity
Connections
- Input: RJ9 (4P4C) for air velocity sensor
- Output: RJ11 / RJ12 (6P4C) to the monitoring system
- Cable: 2 m telephone cable included in delivery
- Maximum distance: up to 50 m to the central unit
Electrical Data
- Power consumption: 60 mW
Environmental Conditions
- Operating temperature: -10 °C to +80 °C
- Humidity: 5 % to 95 % (non-condensing)
Mechanical Data
- Dimensions: 600 × 18 × 18 mm
- Weight: 106 g
- Mounting: mounting bracket for installation in IT racks and cabinets included
General
- Origin: EU
- HS code: 9026 80 200