Up to 8 Additional Analog Sensors per Expansion Unit
The Didactum Sensor Expansion Unit 8x Analog is a highly flexible CAN bus expansion designed specifically to significantly increase the capacity of any compatible Didactum Monitoring System. Each unit provides 8 additional RJ12 ports for analog sensors and connects directly to the CAN port of the monitoring system.
Thanks to the Autosense function, all connected sensors are automatically detected and displayed in the web interface within seconds, complete with name, type, readings, and status – no manual configuration is required. This saves time, reduces sources of error, and enables fast commissioning, even for large installations with dozens of sensors.
Thanks to intelligent daisy-chain technology over the CAN bus, multiple expansion units as well as other CAN-capable devices and sensors can be easily and space-efficiently linked together in a chain – ideal for monitoring complex, sprawling, or particularly sensitive environments such as data centers, server rooms, production halls, warehouse complexes, or critical infrastructure.
Typical Application Scenarios
The 8-port sensor expansion box can be used in almost any critical environment where the base sensor ports of a Didactum Monitoring System are not sufficient.
Data Centers
Monitoring of temperature, humidity, airflow, water intrusion, and power supply status across hundreds of racks – centrally managed via a Didactum system.
Industry 4.0
Connection of vibration sensors, pressure gauges, level sensors, and analog process variables in manufacturing facilities.
Building Management
Central monitoring of air conditioning, heating, ventilation systems, and security sensors in office complexes or hospitals.
Critical Infrastructure
Early detection of overheating, moisture, or power outages in substations, power plants, or telecommunications hubs.
Key Features of the Expansion Unit
Compact, robust, and ready for use in seconds – the unit was designed for continuous operation in technical rooms.
Compatibility
Suitable for all Didactum Monitoring Systems (50T, 100T, 300T, 500T, 550T, and others).
8 Sensor Ports
8 × RJ11/RJ12 ports (6P4C) for analog sensors with automatic detection.
2 CAN Ports
Two equivalent RJ12 connections (CAN1/CAN2) including an integrated termination switch (TR).
Long Range
Up to 225 m CAN bus length; sensor cables can be run 50–150 m depending on sensor type.
LED Status Indicators
Two LEDs (RUN/ERROR) show connection and configuration status in real time.
Central Configuration
Managed exclusively via the Didactum Monitoring System's web front end – no additional software.
Autosense Function
Connected sensors are automatically detected and integrated into the system in seconds.
Daisy-Chain Capable
Multiple units and other CAN devices can be combined in a single chain.
Scalability in Detail
Up to 10–32 CAN devices can be combined on a single CAN bus line – the exact upper limit depends on the total line length, signal quality, and power supply used. In practice, this means you can operate not only multiple 8-port sensor expansion boxes but also digital inputs, relay modules, temperature sensors, humidity sensors, smoke detectors, door-opening sensors, or motion detectors on a single CAN bus segment.
Up to 24 units of the 8-port sensor expansion box can be operated on a single CAN bus line – equivalent to up to 192 additional analog sensor ports on just one monitoring unit. This makes it possible to monitor even large-scale facilities such as multi-story buildings, production lines, or distributed IT infrastructure with just a single central Didactum system. When the maximum chain length is reached, the CAN-12V-1A power supply is required to ensure adequate power supply along the CAN bus line.
Note: Within a single CAN bus segment (i.e. between two actively terminated endpoints without a CAN power supply), the manufacturer recommends no more than 8 CAN units, sensors, and/or other CAN devices. For larger chains with more participants, use of the CAN-12V-1A power supply is required.
Power Supply and Stability
Normally, an external 12V/0.5A power supply is connected to the socket labeled "PWR." However, if only a single expansion unit is connected and the cable length from the monitoring unit to the expansion box does not exceed 10 m, the unit will also operate without an external power supply. In all other cases, using an external power supply is recommended.
In larger configurations with many expansion units, power demand increases along the CAN bus chain. This is where the dedicated CAN-12V-1A power supply comes in: it is integrated directly into the CAN bus line and reliably supplies power to all downstream devices. Without this additional power supply, voltage would drop too much across long chains or with many devices, which can lead to unstable operation or failures. It is recommended to use the power supply approximately every 8–12 units or whenever the line length exceeds 50 meters.
Flexible Mounting Options
Depending on the installation location, the expansion unit can be mounted in three different ways. The respective mounting accessories are sold separately.
Wall Mounting
Four M3 threaded holes on the bottom of the housing secure the wall bracket for mounting on a wall or surface.
DIN Rail Mounting
Two M4 threaded holes on the bottom of the unit accommodate the DIN rail bracket, used to mount the device onto a DIN rail.
19" Rack Mounting
The rackmount kit allows one or two expansion units to be mounted space-efficiently in 1 rack unit (1U) of a 19" rack.
Matching Mounting Accessories
The following accessories are not included in the scope of delivery and are ordered separately.
Rackmount Kit
Allows mounting of the sensor expansion and device in a 19" server rack at 1U height.
ITEM: DI15001
DIN Rail Bracket
Allows mounting of the expansion unit onto a DIN rail.
ITEM: DI15005
Rackmount Kit for 2 Expansion Units
Allows two expansion units to be mounted together in a 19" server rack at 1U height.
ITEM: DI15002
Setup in a Few Steps
Commissioning is done without additional software directly through the monitoring system's web front end.
- Connect the unit's CAN input to the CAN input of the preceding CAN unit or the monitoring system using the included RJ11/RJ12 cable
- Set the TR bus terminators on the connected CAN units accordingly: only "ON" (i.e. "TR" position) on the last device in the chain, "OFF" on all units in between
- If needed, connect an external 12V power supply to the "Power" socket (required for cable lengths over 10 m or multiple units in the chain)
- Connect analog sensors to ports A1–A8 – they are automatically detected via Autosense
- Access and individually configure the expansion unit and its connected sensors in the Didactum Monitoring System's web interface under "CAN Bus"
- Define the desired notification and alarm types (email, SMS via optional GSM modem, SNMP trap, siren, or relay switching)
What's Included
Please check the delivery for completeness upon receipt and report any missing or damaged parts to your supplier immediately.
- Didactum Expansion Unit (8x Analog)1 piece
- RJ11/RJ12 connection cable (CAN)1 piece
- Quick start guide1 piece
Wall bracket, DIN rail bracket, rackmount kit, and an additional CAN-12V-1A power supply are optional accessories and are not included in the scope of delivery.
Why the Expansion Unit Is the Right Choice
+8 Sensor Ports
Each unit immediately extends the system by 8 analog sensor connections.
Autosense
Connected sensors are automatically detected and configured.
Daisy-Chain
Up to 24 units per CAN bus line – up to 192 additional ports.
Long Range
Up to 225 m CAN bus length for flexible installations.
Flexible Mounting
Wall, DIN rail, or 19" rack mounting possible.
No Additional Software
Configuration entirely through the monitoring system's web interface.
Compact & Robust
Small housing (129 × 28.6 × 56 mm), operation from -10 °C to +80 °C.
Made in EU
Developed and manufactured in the European Union.
Practical Applications
- Expanding a Didactum Monitoring System with additional temperature and humidity sensors
- Connecting further smoke detectors, water sensors, and door contacts in server rooms
- Building large sensor networks in multi-story buildings via daisy-chaining
- Retrofitting existing monitoring installations without replacing the base unit
- Distributed sensor points in production lines and warehouses
- Central monitoring of multiple racks via a single CAN bus chain
The Didactum Sensor Expansion Unit 8x Analog enhances the capabilities of any Didactum Monitoring System by enabling the addition of further analog sensors, ensuring comprehensive environmental monitoring and reliable protection of critical infrastructure.
More on the Expansion Unit
Installation & Commissioning
Detailed instructions on connections, LED status, mounting, and setup of the 8-port sensor expansion box.
Go to instructions →Firmware & Updates
Current firmware versions along with instructions for updating and recovery.
Go to firmware page →Live Demo
Try out the web interface of the Didactum Monitoring System online, no obligation.
Go to demo →Frequently Asked Questions
What is the Didactum Sensor Expansion Unit 8x Analog and what is it used for?
It is a CAN bus expansion that increases the number of analog sensors that can be connected to a Didactum Monitoring System by 8 ports at a time. It is needed when the built-in sensor ports of a monitoring system (e.g. 4 or 8 ports) are not sufficient and additional temperature, humidity, smoke, water, or motion sensors need to be connected.
Which Didactum Monitoring Systems is the expansion unit compatible with?
The expansion unit is compatible with all Didactum Monitoring Systems that feature a CAN bus port, including the 50T, 100T, 300T, 500T, and 550T models.
How many expansion units can I connect to a monitoring system?
Up to 24 expansion units can be operated on a single CAN bus line, equivalent to up to 192 additional analog sensor ports. In general, up to 10–32 CAN devices can be combined on a CAN bus line; the exact limit depends on line length, signal quality, and power supply. For a single CAN bus segment without an additional power supply, the manufacturer recommends no more than 8 CAN units or sensors.
Do I need an additional power supply for the expansion unit?
If only a single expansion unit is connected and the cable length to the monitoring system is 10 m or less, the unit operates without an external power supply. In all other cases, as well as when more than 12 CAN devices are in the chain, an external 12V/0.5A power supply or the CAN-12V-1A power supply is recommended or required to stabilize the power supply.
What mounting options are available for the expansion unit?
The unit can be mounted on a wall or surface using a wall bracket, attached to a DIN rail via a DIN rail bracket, or installed with up to two units in 1 rack unit of a server cabinet using a 19" rackmount kit. The respective mounting accessories are sold separately.
How do I set the TR termination correctly?
The TR switch must be set to "TR" (to the left) if the unit is the last one in the CAN bus chain or if the chain length exceeds 10 m. For all units in between in the chain, "TR" remains switched to the right (off).
Questions about the Expansion Unit?
Our support team in Germany is happy to advise you free of charge on selection, scaling, installation, and compatibility.
Datasheet 1
Didactum Expansion Unit for Sensors 8x Analog
Function
- Expansion unit for connecting additional analog sensors to Didactum monitoring systems
- Each unit expands the system with 8 additional analog sensor ports
- Automatic detection and integration of all connected sensors
- Ideal for scaling complex monitoring and infrastructure environments
CAN Bus Expansion
- Supports daisy-chain cabling via CAN bus
- Up to 10–32 CAN devices per CAN bus chain possible
- Up to 24 expansion modules per CAN bus line supported
- Compatible with additional CAN sensors and expansion modules
Communication
- Device type: CAN bus expansion device
- Network interface: CANopen
- Inputs: 8 × analog sensor ports RJ11/RJ12 6P4C
- CAN connections: 2 × RJ-12
- Chain connection: yes
System Expansion
- Suitable for expanding complex monitoring environments
Power Supply
- Input voltage: 12V DC
- Maximum CAN bus length: 225 m
- Maximum sensor cable length: 50–150 m (depending on sensor type)
- If more than 12 CAN devices are used within a CAN bus chain, an additional CAN 12V/1A power supply is required
Mechanical Data
- Dimensions: 129 × 28.6 × 56 mm
- Weight: 0.5 kg
- Status indicators: Red (error) / Green (operation)
- TR switch for activating the termination resistor at the end of the CAN bus chain
Mounting Options
- Wall mounting (optional)
- 1U mounting kit for 2 × units (optional)
Environmental Conditions
- Operating temperature: -10 °C to +80 °C
General
- Origin: EU
- HS Code: 8471 50 000