Switchable power distribution with 8 sockets, Gigabit Ethernet and environmental monitoring
The Didactum PDU-8T is a versatile, network-capable power distribution unit for effective load management in server rooms and technical cabinets. It allows switching on and off as well as remote reboot of up to eight individual sockets, providing flexible control over connected devices such as servers, network equipment or peripheral devices – ideal for racks with a higher number of devices.
As one of the few switchable PDUs with true Gigabit Ethernet (10/100/1000 Mbit/s), the PDU-8T is particularly suitable for environments where a high-performance network connection is required. In addition, it acts as a fully-fledged I/O controller: analogue sensor ports, a CAN bus for digital sensors, potential-free contacts and 12V relay outputs make it possible to centrally manage door control, fans, generators, UPS systems, circuit breakers and alarm systems.
With the ability to manage up to 700 elements – including notifications, triggers, timers, logic schemes, sensors and potential-free contacts – the PDU-8T offers robust functionality even for complex setups, controlled via an intuitive integrated web interface.
Eight sockets, individually remotely controllable
Each of the eight C13 sockets (110–240V AC, 50/60 Hz, bistable relays) can be switched on and off or rebooted independently of the others.
On / Off
Each socket can be switched manually or automatically via logic schemes.
Remote reboot
Non-responsive devices can be made accessible again by rebooting them remotely.
Bistable relays
The last switching state of each socket is retained even in case of a short power failure.
Logic schemes
Switching operations can be linked to conditions such as sensor values or schedules.
Gigabit Ethernet for high-performance environments
The PDU-8T features a 10/100/1000 Mbit/s Ethernet interface and is therefore one of the few switchable PDUs with full Gigabit Ethernet support. IPv4 is supported natively, IPv6 is available on request. This allows the PDU-8T to be integrated into networks with high data volumes without bottlenecks.
Far more than pure power distribution
In addition to socket control, the PDU-8T serves as a fully-fledged I/O controller for sensors and peripheral devices.
2 analogue sensor ports
For classic Didactum analogue sensors such as temperature or humidity.
CAN bus (2 ports)
For digital CAN sensors and extensions in a daisy chain.
2 potential-free contacts
For door, window or status contacts of external devices.
2 x 12V/0.25A relay outputs
For alarm sounders, sirens or other 12V actuators.
Integrated temperature sensor
Accuracy ±1 °C, integrated directly into the device.
USB camera & SD card
Micro-USB for camera connectivity, MicroSD slot for logs and system recovery.
This makes the PDU-8T suitable, for example, for door control, fan control, generator control, UPS monitoring, circuit breaker automation and integration of alarm systems.
Designed for eight sockets
Since the PDU-8T supplies twice as many sockets as the PDU-4T, the mains input is dimensioned accordingly.
C20 mains input
110–240V AC, 50/60 Hz, designed to supply all 8 sockets.
16A fuse
Larger input fuse compared to the PDU-4T (10A).
12V DC backup
Additional backup power input that takes over if the main power fails.
Optional extension modules
Via separately available extension modules, the PDU-8T can be adapted to individual requirements.
4G modem
For a network connection via mobile network, independent of the main line.
Modbus RTU extension
For integration of Modbus RTU-capable devices.
OSDPv2 reader extension
Alternative to the Modbus module for connecting access readers.
Of the two extension slots, only one module can be installed in each slot at a time (4G modem slot or Modbus/OSDP extension slot).
Full control via web interface, app and protocols
The integrated web interface provides access to virtual sensors, logic schemes and a wide range of notification types.
- Notifications via e-mail, FTP log, syslog, SMTP, SNMP traps, web-to-SMS and push
- Supported protocols: DHCP, HTTP, HTTPS, DynDNS, SSL, SNMP v1/v2c/v3, SMTP, FTP, Syslog, RADIUS, Modbus RTU, OpenVPN
- Virtual sensors: PING, timer, triggers, logic schemes, SNMP GET, up to 4 IP cameras, virtual calculation elements and more
- Environmental monitoring: temperature, humidity, voltage, water ingress, smoke and airflow via connected sensors
- Management of up to 700 elements such as notifications, triggers, timers, logic schemes and sensors
Application areas of the Didactum PDU-8T
The PDU-8T is suitable wherever reliable load management for a larger number of consumers is to be combined with environmental monitoring.
- Data centres: efficient power management for servers and network equipment with optimal load distribution over 8 sockets
- Remote maintenance: remote reboot of non-responsive systems to avoid on-site interventions
- Environmental monitoring: centrally monitor temperature, humidity, voltage and smoke and generate automatic alarms
- Control of peripheral devices such as fans, generators and UPS systems in case of power failures
- Door control and access management via potential-free contacts and alarm relays
- Racks with high device density where a single 4-way PDU is no longer sufficient
What is included in the scope of delivery
Please check the scope of delivery upon receipt for completeness and immediately report missing or damaged parts to your supplier. In case of transport damage, please contact the responsible carrier directly.
- Power Distribution Unit Didactum PDU-8T1 piece
- Power cable Schuko to C13, 0.75 mm², 230V/10A1 piece
- Power cable IEC C13 socket to C14 plug2 pieces
- RJ-45 patch cable, 3 m (LAN/Ethernet)1 piece
- Micro-USB to USB adapter cable1 piece
- Terminal block, 3-pin, 3.81 mm1 piece
- Terminal block, 3-pin, 3.5 mm1 piece
- Terminal block, 2-pin, 3.81 mm1 piece
- 19" rack mounting brackets2 pieces
- Screws M3 x 8 mm6 pieces
- Self-adhesive rubber feet4 pieces
- Configuration guide1 piece
- Warranty card1 piece
Why the Didactum PDU-8T is the right choice
8 x remotely controllable
Switch on/off and reboot each socket independently of the others.
Gigabit Ethernet
Full 10/100/1000 Mbit/s network connection instead of Fast Ethernet only.
Fully-fledged I/O controller
Analogue ports, CAN bus, dry contacts and 12V relays in a single device.
Powerful input section
C20 connector with 16A fuse designed for 8 sockets.
Modular expandability
Optional 4G modem, Modbus RTU or OSDP extension.
19" rack mounting
Including mounting brackets for direct installation in a 1U rack.
Up to 700 elements
For complex monitoring and automation scenarios.
Made in EU
Developed and manufactured in the European Union.
More about the Didactum PDU-8T
Device detail page & tutorial
Overview of the device, interfaces, dimensions and all technical data in detail.
Go to detail page →Frequently asked questions
How many sockets can be switched independently?
The PDU-8T provides 8 C13 sockets (110–240V AC, bistable relays), each of which can be switched on and off or rebooted individually – manually via the web interface or automatically via logic schemes.
What is the difference between PDU-4T and PDU-8T?
The PDU-8T offers double the capacity with 8 instead of 4 sockets and therefore features a more powerful C20 mains input with a 16A fuse instead of a C14 input with 10A. The other functions such as Gigabit Ethernet, I/O controller and expansion options are identical.
Which sensors and devices can be connected additionally?
Via 2 analogue sensor ports and 2 CAN bus ports, classic analogue sensors as well as digital CAN sensors and extensions can be connected. In addition, 2 potential-free contacts and 2 x 12V/0.25A relay outputs are available for alarm sounders or other actuators.
Which extensions are available for the PDU-8T?
Optionally available are a 4G modem for a mobile network-based connection as well as a Modbus RTU extension or alternatively an OSDPv2 reader extension. Of the two extension slots, only one module can be used at a time.
Can a camera be connected for alarm verification?
Yes, a USB camera can be connected via the Micro-USB port and used for visual monitoring and recording of events.
The device does not start – what could be the reason?
First check the position of the “N…R” DIP switch on the rear side. If it is set to “R” (Restore), the device will not start in normal mode. Set the switch to “N” (Normal) to restore normal operation.
Questions about the Didactum PDU-8T?
Our support team in Germany will advise you free of charge on selection, installation and configuration.
Gerätebeschreibung | ||
|
| Didactum PDU 4T | Didactum PDU 8T |
| Beschreibung |
|
|
| Geräteverwaltung | Web/SNMP | Web/SNMP |
| Sensorzugang | Dreistufig nach Login | Dreistufig nach Login |
| Schnittstelle und unterstützte Protokolle | ||
| LAN | Ethernet 10/100 Mbit | Ethernet 10/100 Mbit |
| Betriebssystem | Linux v. 6.2 | Linux v. 6.2 |
| Benutzeroberfläche | Beliebiger Browser | Beliebiger Browser |
| Memory RAM | 128 Mb | 128 Mb |
| CPU Geschwindigkeit | 720 MHz | 720 MHz |
| CPU Kerne | 2 | 2 |
| Uhr | Built-in | Built-in |
| Timer | Built-in Watchdog | Built-in Watchdog |
| Maximale Anzahl von Sensoren: physikalische Sensoren, Trockenkontakte, Relais | 100 | 100 |
| Maximale Anzahl von Elementen: Benachrichtigungen, Trigger, Timer, Logik, Sensoren, Trockenkontakte, SNMP Get, SNMP Trap, Dial Task und andere Elemente | 700 | 700 |
| Netzwerk / Protokollunterstütung | ||
| LTE-Gateway-Modus | Internetzugang (Routing für internes Netzwerk) Modem separat zu bestellen | Internetzugang (Routing für internes Netzwerk) Modem separat zu bestellen |
| LTE-Zugangsmodus | Internetzugang über LTE (Modem separat zu bestellen) | Internetzugang über LTE (Modem separat zu bestellen) |
| Netzwerkprotokplle: | DHCP; HTTP; HTTPS; SNMP v1, v2c, v3; SMTP; FTP; Syslog; TLS | DHCP; HTTP; HTTPS; SNMP v1, v2c, v3; SMTP; FTP; Syslog; TLS |
| Modbus RTU (nur mit USB-Konverter) | Mit Erweiterung | Mit Erweiterung |
| Modbus TCP / IP | Ja | Ja |
| Static Routing | Ja | Ja |
| Dynamic DynDNS | Ja | Ja |
| Zugang über RADIUS-Server | Ja | Ja |
| VPN | Ja | Ja |
| SSL Installation | Ja | Ja |
| NTP Server | Ja | Ja |
| Alarme / Benachrichtigungen | ||
| Alarmarten | E-Mail, FTP-Protokoll, Syslog, SMTP, SNMP-Traps, SMS (Modem ist separat zu bestellen), Web-to-SMS | E-Mail, FTP-Protokoll, Syslog, SMTP, SNMP-Traps, SMS (Modem ist separat zu bestellen), Web-to-SMS |
| Maximale Anzahl der "Mail to"-Empfänger in einer E-Mail-Benachrichtigung: | 20 | 20 |
| Eine maximale Anzahl von "SMS an"-Empfängern in einer SMS-Benachrichtigung: auch die maximale Anzahl von Telefonnummern | 20 | 20 |
| Virtuelle Sensoren | ||
| Ping | Integriertes Pingen | Integriertes Pingen |
| IP-Kameras: Verbinden Sie die IP MJPEG-Kamera mit einem Proxy über das Master-Modul. Nur Anzeige, keine Aufzeichnung. | 4 | 4 |
| Get SNMP | Lesen von Daten aus externen Geräten über SNMP PDU GET (v1/2c) | Lesen von Daten aus externen Geräten über SNMP PDU GET (v1/2c) |
| Logische Schemata: | Ja | Ja |
| Timer | Ja | Ja |
| Trigger | Ja | Ja |
| SNMP Traps | Ja | Ja |
| Virtuelles mathematisches Element | Ja | Ja |
| Logische Schemata | Ja | Ja |
| Modbus TCP/IP | Read / Write | Read / Write |
| Stromversorung | ||
| Stromzufuhr | 110-240V, 50-60 Hz | 110-240V, 50-60 Hz |
| Eingang / Einlass: 110-240V AC, 50/60Hz | C14 Fuse 10A | C20 Fuse 16A |
| Sicherung | 10A | 16A |
| Ausgänge /Steckplätze: Bistabile Relais mit Anzeige auf der Frontplatte. C13, 110-240V AC, 50/60 Hz. | 4 | 8 |
| Stromverbrauch | ||
| Gesamte Stromlast | 2,4 kW |
|
| Leistungsmessung | Nein | Nein |
| Eingangsklemme für die Stromreservierung | DC 12V Notstromversorgung, 3,81mm, 2P | DC 12V Notstromversorgung, 3,81mm, 2P |
| Ausgänge | ||
| Relaisausgänge: 12V 0,25A | x2 | x2 |
| Sockets | x4 IEC 320 C13 | x8 IEC 320 C13 |
| Eingänge | ||
| Analoger Anschluss: 6P6C für den Anschluss eines analogen Sensors. (erweiterbar über CAN-Bus) | x2 eingebaut & erweiterbar | x2 eingebaut & erweiterbar |
| CAN-Anschluss: Anschluss von CAN-Bus-Sensoren und -Geräten | x1 Anschluss, max. 32 Geräte | x1 Anschluss, max. 32 Geräte |
| Trockenkontakteingänge (Kontaktschließer/Digitaleingänge) | x2 eingebaut & erweiterbar | x2 eingebaut & erweiterbar |
| Modbus RTU (RS-485): Max. Leitungslänge 1000m | Durch Erweiterung | Durch Erweiterung |
| OSDP v2 reader | Durch Erweiterung | Durch Erweiterung |
| Weitere Anschlüsse | ||
| Ethernet Port | 10/100 Mbit | 10/100 Mbit |
| Micro USB | USB 2.0 HS | USB 2.0 HS |
| Switch Normal / Recovery: | setzt das Gerät auf die Werkseinstellungen zurück | setzt das Gerät auf die Werkseinstellungen zurück |
| Externer Speicher / Logs | ||
| Micro SD Kartensteckplatz | SDXC bis zu 512 GB | SDXC bis zu 512 GB |
| SD-Karten-Formatierung | FAT 32 | FAT 32 |
| USB-Flash-Laufwerk: Protokolle, Sensormesswerte, Elementeinstellungen usw. | Ja | Ja |
| Senden des Systemprotokolls an E-Mail: Protokolle, Sensordaten, Elementeinstellungen, etc. | Ja | Ja |
| Sensor-Dump-Dateien: Speichern der sekündlichen Abtastwerte von analogen Sensoren und Detektoren | Ja | Ja |
| Senden an FTP-Server: Protokolle, Sensordaten, Elementeinstellungen usw. | Ja | Ja |
| Maximale Anzahl von Protokolldateien: | 10.000 Protokolle/Tage | 10.000 Protokolle/Tage |
| Stichprobenrate/Zeitraum (Protokolle, Diagramme) | 1 s | 1 s |
| Syslog | Ja | Ja |
| Umgebungsmerkmale | ||
| Betriebstemperatur: | 0 bis 60°C | 0 bis 60°C |
| Lagertemperatur | -25 bis 85°C | -25 bis 85°C |
| Betriebsfeuchtigkeit | 0 bis 90%, nicht kondensierend | 0 bis 90%, nicht kondensierend |
| Lagerfeuchtigkeit | 0 bis 95%, nicht kondensierend | 0 bis 95%, nicht kondensierend |
| Sonstige Merkmale | ||
| Installation | 19“ | 19“ |
| Maße (L x B x H) in mm | 440 x 44 x 80 | 440 x 44 x 80 |
| Gewicht | 1,3 kg | 1,5 kg |
| Externe Chassis-Erdung | M4-Gewinde | M4-Gewinde |