The compact backup power supply for 12 V devices with power failure notification
The HW group UPS 12V is a backup power source for devices with 12 V DC supply. It delivers a stable output voltage of 12 V at up to 1.5 A and reports a failure of the external power supply via an integrated relay output. In terms of power supply, the UPS 12V is compatible with all HW group devices that are operated with 12 V power adapters.
In the IT sector, industry and households, an uninterruptible power supply is standard. For small devices such as monitoring systems, telephone systems (PBX) or controllers with a 12 V power adapter, however, there are hardly any suitable solutions, and a complex 230 V UPS is uneconomical for this purpose. This is where the UPS 12V comes in: it protects your device without significantly increasing the installation requirements.
Reliably protect small devices
The UPS 12V bridges power failures with a built-in battery and provides a timely signal to the connected device.
Built-in battery
The 1.3 Ah battery automatically takes over the supply of the connected device in the event of a mains failure.
Stable 12 V up to 1.5 A
Stable output voltage of 12 V with a load of up to 1.5 A.
Relay output
Failure of the external power supply is reported via a signal relay (50 V / 1 A).
Connection via pin connector
The device to be protected is simply connected to the pin connector (Power Out).
Same power adapter as the end device
The UPS is operated with a standard 12 V / 1.5 A power adapter, as is often already available for the end device.
Also with 5 V output
The UPS 12V and 5V variant additionally supplies devices with 5 V and reports its status via 1-Wire UNI.
Clear LED indicators
The green Power IN and Power OUT LEDs indicate mains and output status.
Compact and simple
Plastic housing with mechanical main switch, 135 x 60 x 90 mm, 750 g.
Four versions to choose from
The UPS 12V is available as a basic version and as a set with power adapter, each with and without an additional 5 V output.
Please note: The version must be selected above the shopping cart button via the “Select UPS12xx variant” option so that the desired version is ordered. A power adapter is only included in the two set versions.
UPS 12V
Basic version with UPS unit, 12 V / 1.3 Ah battery, pin connector for the device to be protected and integrated relay output for signalling power failures. A power adapter is not included, as the UPS is operated with a standard 12 V / 1.5 A power adapter that is often already available for the end device.
UPS 12V Set
The UPS 12V unit together with a matching 12 V / 1.5 A power adapter, which simplifies installation. Also includes the pin connector and the relay output function. Ideal for users who need a complete solution without additional components.
UPS 12V and 5V
Extends the functionality with an additional 5 V output that can be operated simultaneously with the 12 V output. With pin connector for both voltages and 1-Wire UNI output for status information. A power adapter is not included.
UPS 12V and 5V Set
Complete set consisting of UPS unit with 12 V and 5 V outputs and a 12 V / 1.5 A power adapter. Ideal for applications that need to protect 12 V and 5 V devices at the same time, e.g. combined network and control systems.
How the UPS 12V is designed
The UPS 12V is housed in a compact plastic enclosure (135 x 60 x 90 mm, 750 g). Connections, main switch and LEDs are easily accessible on the housing. The equipment differs depending on the version.
Barrel connector for the power adapter (Power IN)
External connection for the power adapter with 12 V, at least 1.5 A. The manufacturer specifies a barrel connector with 2.1 mm inner and 5.5 mm outer diameter.
Main switch
The red switch disconnects the battery. It may only be switched on during operation. If the UPS is not in use, switch the main switch off.
LED indicators
Power OUT lights up when the UPS output is switched on. Power IN lights up when the external power supply is connected. On the UPS 12V and 5V version, Overload (overload of the 12 V or 5 V branch) and Battery Fail (flashes in the event of battery failure) also indicate the status.
Pin connector Power Out
The device to be protected is connected here. On the UPS 12V it is a dual pin connector with 12 V. On the UPS 12V and 5V it is a triple pin connector (+5 V, GND, +12 V) with common ground potential (GND).
Pin connector of the signal relay (UPS 12V)
Triple pin with the connections NO (normally open), COM (common contact) and NC (normally closed). An outer pin is always connected to the middle pin (COM). The contact is rated for 50 V / 1 A.
1-Wire UNI output (UPS 12V and 5V)
Connection for linking to a Poseidon2 or Ares 10. The status of the UPS is transmitted via this.
Reset/Start (UPS 12V and 5V)
Restores the power supply after an overload.
Battery
Built-in battery with 1.3 Ah. The UPS 12V and 5V additionally contains an internal 5 V converter for the 5 V output.
From mains operation to battery operation
The UPS is supplied by the same 12 V power adapter that also powers the end device. In the event of a failure, the battery takes over.
- In normal operation, the power adapter supplies the UPS and thus the connected device; the battery is charged
- If the external power supply fails, the 12 V battery immediately takes over the supply
- The Power IN LED goes out, the Power OUT LED remains lit
- On the UPS 12V the signal relay opens at the same time (NO opens, NC closes)
- The supplied device can report the failure or correctly terminate its activity
- After the power supply returns, the relay closes again and the battery is charged
- On the UPS 12V and 5V the 1-Wire UNI output reports battery voltage, battery current, the estimated operating time at the current load and the status of mains or battery operation
- Each of these values occupies a sensor position in the connected device. Values that are not required can be disabled via the “1-Wire UNI USB Calibrator”
Connection and functional check
Commissioning is carried out in a few steps.
- Connect the 12 V / 1.5 A power adapter to the UPS. Both green LEDs light up
- Connect the device to be protected to the Power Out pin connector
- Optional: Connect the relay output (UPS 12V) or 1-Wire UNI output (UPS 12V and 5V) to the monitoring device
- Switch on the UPS at the main switch
- For a functional check, unplug the power adapter: the Power IN LED goes out, the Power OUT LED remains on
- If the UPS is switched off at the main switch, the Power OUT LED also goes out
Suitable for HW group devices
The UPS 12V is compatible with all HW group devices that are operated with 12 V power adapters.
- Poseidon2 (3268, 4002)
- Damocles2 (MINI, 1208, 2404)
- HWg-Ares 12 and Ares 12 LTE
- Perseus Industrial 300, 310 and 315
- Perseus Energy 240
- Perseus Monitoring 140, 145, 150 and 155
- IP WatchDog2 (Industrial, Lite)
- PortStore5
- 1-Wire sensors such as Sensor 4-20mA 1W-UNI and Sensor WLD Relay 1W-UNI
- STE2 and HWg-WLD (listed as related products in the datasheet)
- Example in the datasheet: UPS 12V and 5V protects Poseidon2 3268 and STE2, status is transmitted via 1-Wire UNI
- Example in the datasheet: UPS 12V protects Damocles2 MINI, status is transmitted via the relay output
Important note on the main switch
Please note: The status of the UPS main switch is not indicated and must be checked visually by the switch position. The main switch disconnects the battery: Switch it on only during operation and off when the UPS is not in use.
Why the UPS 12V is the right choice
Right size
A compact alternative to a 230 V UPS for small 12 V devices.
Simple installation
Same 12 V power adapter as the end device, connection via pin connector.
Failure is reported
Relay output or 1-Wire UNI informs about the power failure.
Flexible versions
With or without 5 V output, with or without power adapter.
For HW group devices
Compatible with all HW group devices with 12 V power adapter.
24 months warranty
According to the manufacturer.
Typical areas of use
- Server room monitoring: Protection of sensors and monitoring devices
- Monitoring of switchboards
- Industrial control systems
- Security systems
- Network devices: Routers, switches or PBX systems
- Household applications: Smart home devices or security cameras with 12 V or 5 V
- IT, industry and households where a 230 V UPS would be uneconomical for small devices
- Reporting of power failures to the connected device so that it can safely terminate its activity
Frequently asked questions
What is the UPS 12V and what is it used for?
The UPS 12V is a backup power source for devices with 12 V DC supply. It delivers 12 V at up to 1.5 A, bridges power failures with its battery and reports the failure of the external supply via a relay output. Typical applications are monitoring systems, telephone systems and controllers.
Are there options or variants?
Yes, four: UPS 12V, UPS 12V Set (with power adapter), UPS 12V and 5V (additional 5 V output) and UPS 12V and 5V Set (with power adapter). Selection is made above the shopping cart button.
Is a power adapter included in the scope of delivery?
Only with the set versions. The basic versions UPS 12V and UPS 12V and 5V are supplied without a power adapter, as the UPS is operated with a standard 12 V / 1.5 A power adapter that is often already available for the end device.
Which power adapter is required?
A power adapter with 12 V and at least 1.5 A. Connection is via a barrel connector (inner 2.1 mm, outer 5.5 mm). The manufacturer offers, among others, the “12V/1.5A Wall plug adaptor INT” with three interchangeable plugs (EUR, UK, US).
What does the relay output mean?
On the UPS 12V a signal relay (50 V / 1 A) signals the power failure. NO is open in the idle state, i.e. when the power supply is disconnected, and closes when the device is supplied from the external power adapter during operation. NC closes in the event of a failure of the external supply. In this way the connected device can report the failure or safely terminate its activity.
What is the difference between UPS 12V and UPS 12V and 5V?
The UPS 12V and 5V additionally has a 5 V output (12 V / 1.5 A and 5 V / 0.5 A, usable simultaneously) with an internal 5 V converter. Instead of the signal relay it offers a 1-Wire UNI output with status values and additionally the Overload and Battery Fail LEDs as well as the Reset/Start button. The UPS 12V delivers 12 V up to 1.5 A and reports via the relay.
Which status values does the 1-Wire UNI output provide?
On the UPS 12V and 5V: battery voltage, battery current, estimated operating time at the current load and mains or battery operation. Each value occupies a sensor position in the connected device (e.g. Poseidon2 or Ares 10). Values that are not required can be disabled via the “1-Wire UNI USB Calibrator”.
How do I check the function?
Connect the power adapter, switch on the UPS and then unplug the power adapter. The Power IN LED goes out, the Power OUT LED remains on. When the UPS is switched off, Power OUT also goes out.
What do the LEDs mean?
Power OUT: output switched on. Power IN: external power supply connected. Overload (UPS 12V and 5V): overload of the 12 V or 5 V branch. Battery Fail (UPS 12V and 5V): flashes in the event of battery failure. After an overload the Reset/Start button restores the power supply.
Is the status of the main switch indicated?
No. The status of the main switch is not indicated and must be checked by the switch position. The main switch disconnects the battery and should only be switched on during operation.
What is the battery capacity?
1.3 Ah at 25 °C. The capacity depends on the temperature: 85 % at 0 °C, 100 % at 25 °C and 102 % at 40 °C.
What load can the UPS supply?
The UPS 12V delivers up to 1.5 A at the 12 V output. The UPS 12V and 5V delivers 12 V / 1.5 A plus 5 V / 0.5 A; both outputs can be used simultaneously.
Which devices is the UPS 12V compatible with?
With all HW group devices that are operated with 12 V power adapters, e.g. Poseidon2, Damocles2, Ares 12, Perseus and IP WatchDog2.
Questions about the UPS 12V?
Our support team in Germany will advise you free of charge on selection, sensors and configuration.
- UPS 12V:
Includes 12V/1.3Ah battery and a pin connector for connecting the device to be protected - NO power supply included - UPS 12V Set:
UPS 12V unit and a matching 12V/1.5A power supply, including pin connector and relay output function. - UPS 12V and 5V:
Includes an additional 5V output that can be operated simultaneously with the 12V output - NO power supply included - UPS 12V and 5V Set:
UPS unit with 12V and 5V outputs a 12V/1.5A power supply and dual terminal connectors.
UPS 12V and 5V
Output Voltage/Current:
- 12 V / 1.5 A + 5 V / 0.5 A
- Simultaneous power supply to devices at both outputs possible
Power Adapter:
- 12 V / 1.5 A
Accumulator:
- Capacity: 1.3 Ah (at 25 °C)
- Temperature-dependent capacity: 0 °C = 85%, 25 °C = 100%, 40 °C = 102%
Signaling:
- 1-Wire UNI output: 1×
- Accumulator voltage
- Accumulator current
- Estimated operating time at current UPS load
- Status: Mains operation / Battery operation
Dimensions (W × H × D) / Weight:
- 135 × 60 × 90 mm / 750 g
Operating Temperature Range:
- -20 °C to +60 °C
Accumulator Switch:
- Mechanical
UPS 12V
Output Voltage/Current:
- 12 V (double pin) / 1.5 A
Power Adapter:
- 12 V / 1.5 A
Accumulator:
- Capacity: 1.3 Ah (at 25 °C)
- Temperature-dependent capacity: 0 °C = 85%, 25 °C = 100%, 40 °C = 102%
Signaling:
- Signaling relay: 50 V / 1 A
- NO (Normally Open): Opens in case of power failure
- NC (Normally Closed): Closes in case of power failure
Dimensions (W × H × D) / Weight:
- 135 × 60 × 90 mm / 750 g
Operating Temperature Range:
- -20 °C to +60 °C
Accumulator Switch:
- Mechanical
LED Indicators
Status LEDs:
- Power OUT – lights up when UPS output is on
- Power IN – lights up when external power supply is connected
- Overload – lights up when the 12V or 5V branch is overloaded
- Battery Fail – flashes in case of accumulator failure
Further monitoring devices
Available sensors
Accessories
DB9 LapLink Cable 2m A LapLink cable (also known as Lablink or null-printer cable) is a cable used to connect two computers directly via a cable connection. Housing: Plastic Type: Cable
Mounting Plate D Bracket for Ares and Poseidon2 Operating environment: -3°C - 85°C / 0%RH - 100%RH Storage environment: -30°C - 60°C / 5%RH - 95%RH Dimensions: 74 x 6 x 120 (W x H x D) / 58g Warranty: 24 months Wall mounting plate for Ares, Poseidon2 3266/68 and other products.
DIN-Rail Box Set A mounting kit for installing HW-group devices on a DIN rail. Applications and Use: Mounting kit for installing HW-group devices with metal housing on a DIN rail. Operating environment: -30°C - 85°C / 0%RH - 100%RH Storage environment: -30°C - 60°C / 5%RH - 95%RH Dimensions: 45 x 11 x 105 (W x H x D) / 22g
Mounting Kit Screw set for mechanical mounting Applications and Use: Screw set for mechanical fastening
Mounting Plate E- 1U Rack (cabinet) mounting plate, 1U mounting for HW-group Ares and Poseidon2 devices Operating environment: -30°C - 85°C / 0%RH - 100%RH Storage environment: -30°C - 60°C / 5%RH - 95%RH Dimensions: 127 x 45 x 94 (W x H x D) / 137g Warranty: 24 months Rack (cabinet) mounting plate, 1U mounting for HW-group Ares, Poseidon2 3266/3268 and other products.
Mounting Plate L DIN Rail DIN rail mounting plate for Ares, Poseidon2 3268, and other products. Features: Metal housing Wall mounting Applications and Use: Profiles for metal-encapsulated HWg devices for wall mounting. Dimensions: 150 x 120 x 45 (W x H x D) / 65g Warranty: 24 months
Mounting Kit for Poseidon2 4002 and HWg-SMS-GW3 Applications and Use: Mounting kit for Poseidon2 4002 and HWg-SMS-GW3 Operating environment: -30°C - 85°C / 0%RH - 100%RH Storage environment: -30°C - 60°C / 5%RH - 95%RH Dimensions: 136 x 45 x 16 (W x H x D) / 165g Warranty: 24 months
Rack Shelf 1U A versatile solution for easy mounting of HW-group devices in 1U racks. Operating environment: -30°C - 85°C / 0%RH - 100%RH Storage environment: -30°C - 60°C / 5%RH - 95%RH Dimensions: 485 x 44 x 104 (W x H x D) / 597g Warranty: 24 months Housing: Metal Type: Wall mounting This shelf makes it easy to use devices in racks. You can even combine different 1U products and sensors.
Software
Manufacturer information:
HW group s. r. o.
Rumunská 26
Prague, 120 00
Czech Republic
Phone: +420 222 511 918
Email: sales@hwg.cz
Responsible person:
Didactum® Security GmbH
Im Mühlenfeld 4
48163 Münster
Deutschland
Fon:
(+49) 250 19 71 63 54 / (+49) 171 33 11 577
Email: info@didactum-security.de