€217.30
The Pt100 Cable Probe for Flexible Mounting and an Extended Measuring Range
The HW group Temp-485-Pt100 Cable3 is an industrial temperature sensor in which the actual Pt100 probe is separated from the RS-485 converter housing by a 2-meter cable. This allows the sensor to cover an extended measuring range of -50°C to +200°C and to be positioned flexibly at hard-to-reach measuring points or locations remote from the converter housing.
The converter housing is designed for wall mounting, is protected to IP65 against dust and water jets, and communicates via the RS-485 interface using a simple ASCII protocol. The probe itself additionally achieves protection class IP67. The Temp-485-Pt100 Cable3 is specifically designed for connection to the Poseidon2 4002 and is offered as a single version – there are no variants or options for this model.
Extended Measuring Range Thanks to External Cable Probe
By separating the measuring probe from the converter, even extreme temperatures and hard-to-reach measuring points can be reliably monitored.
Measuring Range -50°C to +200°C
Pt100 platinum measuring element with an accuracy of ±(0.25 + 0.002|t|) °C and a resolution of 0.1°C.
2m Cable Probe
The external Pt100 probe is connected to the converter housing via a 2-meter long, shielded silicone cable – ideal for flexible positioning.
IP65 (Converter) / IP67 (Probe)
The converter housing is protected against dust and water jets; the probe itself additionally achieves protection class IP67 for use in damp or wet environments.
RS-485 Communication
Transmission in a simple ASCII text protocol (9600 baud, 8N1); addressing via software or jumper, termination can be enabled via DIP switch.
Designed for Poseidon2 4002
The sensor is specifically designed for integration with the Poseidon2 4002, which jointly handles power supply and data transmission.
Low Power Consumption
Typically 2 mA in measuring mode, approx. 60 mA during RS-485 transmission.
How the Temp-485-Pt100 Cable3 Is Built
The converter housing (approx. 114 x 65 x 35 mm, approx. 181 g total) is designed for wall mounting and is suitable for operating temperatures of -30°C to 70°C (0–100% RH) as well as a storage environment of -30°C to 60°C (5–95% RH).
RS-485 Converter Housing (IP65)
The wall-mountable plastic housing accommodates the RS-485 electronics and is protected against dust and water jets.
External Pt100 Probe on 2m Cable
The measuring element (Pt100/A) is housed in a robust stainless-steel enclosure (material 17240, stem length 50 mm) with protection class IP67 and is connected to the converter via a 2-meter long, shielded 4-core silicone cable.
Terminal Block and RJ11 Connector
Connection to the RS-485 bus and power supply is made via a screw terminal block (CUU 2.5 mm²) as well as via an RJ11 connector.
Addressing and Bus Termination
The RS-485 bus address is set via software configuration or via jumpers; bus termination can be activated via a DIP switch if required.
Simple ASCII Protocol for Temperature Query
The Temp-485-Pt100 Cable3 belongs to the Temp-485-Pt100 product family and uses its simple, text-based RS-485 communication protocol.
- Communication: ASCII (9600 baud, 8N1)
- Multiple sensors can be operated on a shared RS-485 bus
- Address configuration via software or jumpers
- Bus termination optionally switchable via a DIP switch
- Compatible with the SNMP thermometer Poseidon for network connection
Power Supply and Data Transmission from a Single Source
The Temp-485-Pt100 Cable3 is specifically intended for combination with the Poseidon2 4002.
- Power supply directly from the Poseidon2 4002 (12–24 V) or alternatively externally with 10–35 V DC (reverse-polarity protected)
- Transmission of measured values over the Ethernet network via the Poseidon2 4002
- Centralized management of multiple Temp-485-Pt100 Cable3 sensors via a single Poseidon2 4002 device
Installation in a Few Steps
The Temp-485-Pt100 Cable3 is integrated directly into the RS-485 bus wiring of the Poseidon2 4002.
- Mount the converter housing on the wall at the desired location
- Place the external Pt100 probe on the 2 m cable flexibly at the actual measuring point
- Connect the terminal block or RJ11 connector via RS-485 (A, B) to the bus of the Poseidon2 4002
- Establish power supply: either directly from the Poseidon2 4002 (12–24 V) or externally with 10–35 V DC
- Assign a unique bus address via software or jumper if multiple sensors are operated on the same bus
- If required, activate bus termination via the DIP switch if the sensor is located at the end of the bus
- Set up the sensor in the Poseidon2 4002 to provide the measured values over Ethernet
Why the Temp-485-Pt100 Cable3 Is the Right Choice
Flexible Mounting
2 m cable probe enables measurements at hard-to-reach locations.
Extended Measuring Range
-50°C to +200°C for extreme temperatures.
Double Protection
IP65 on the converter, IP67 on the probe.
Optimized for Poseidon2 4002
Power supply and data transmission from a single source.
Precise Pt100 Measurement
High accuracy and 0.1°C resolution.
24-Month Warranty
According to the manufacturer, with 24 months warranty from the date of purchase.
Practical Application Examples
- Server room monitoring
- Industrial processes, tanks and pipelines
- Humid environments with risk of condensation, e.g. cold rooms
- Cooling and heating applications (cold stores, cryogenic systems, high-temperature processes)
- Building technology (HVAC systems)
- Hard-to-reach measuring points where the converter housing must be mounted separately
Practical example: On a pipeline with high process temperature, the external Pt100 probe of the Temp-485-Pt100 Cable3 is attached directly at the measuring point, while the RS-485 converter housing is conveniently mounted on the wall thanks to the 2 m cable. This allows reliable, continuous monitoring via a connected Poseidon2 4002 even in confined spaces or at high temperatures at the measuring point.
Frequently Asked Questions
What is the HW group Temp-485-Pt100 Cable3 and what is it used for?
The Temp-485-Pt100 Cable3 is a Pt100 temperature sensor with an external 2-meter cable probe and an RS-485 converter housing. It is suitable for industrial environments, server rooms, and applications with extreme temperatures or hard-to-reach measuring points.
Are there different variants or options?
No. The Temp-485-Pt100 Cable3 is offered as a single version with a permanently connected 2 m cable. There are no variants or options for this model.
What distinguishes the Cable3 from other Temp-485-Pt100 models?
With the Cable3, the Pt100 probe is separated from the RS-485 converter housing by a 2-meter cable instead of protruding directly as a stem from the housing. This enables flexible positioning at the actual measuring point while the converter can be mounted in an easily accessible location. In addition, the Cable3 covers a significantly larger measuring range of -50°C to +200°C.
Which devices is the sensor compatible with?
The Temp-485-Pt100 Cable3 is specifically designed for connection to the Poseidon2 4002, which handles power supply and data transmission over Ethernet. In addition, it uses the simple RS-485 ASCII protocol common to the entire Temp-485-Pt100 product family.
How accurately does the sensor measure?
The Pt100 probe covers a measuring range of -50°C to +200°C, with an accuracy of ±(0.25 + 0.002|t|) °C and a resolution of 0.1°C.
Is the sensor suitable for humid environments?
Yes. The converter housing meets protection class IP65, the external probe additionally IP67 – both are thus protected against dust and water jets and suitable for humid environments or environments that occasionally come into contact with water.
How is the sensor powered?
The Temp-485-Pt100 Cable3 can be powered directly from the Poseidon2 4002 with 12–24 V or alternatively operated via an external, reverse-polarity protected power source with 10–35 V DC. Power consumption is typically 2 mA in measuring mode and approx. 60 mA during RS-485 transmission.
How is the bus address of the sensor set?
Addressing is performed either via software configuration over the RS-485 interface or via jumpers on the device. Bus termination can additionally be activated via a DIP switch if the sensor is located at the end of the bus.
Questions about the Temp-485-Pt100 Cable3?
Our support team in Germany provides free advice on selection, sensors and configuration.
Monitoring devices
Other available sensors
Extension units
Accessories
Mounting Plate D Bracket for Ares and Poseidon2 Operating environment: -3°C - 85°C / 0%RH - 100%RH Storage environment: -30°C - 60°C / 5%RH - 95%RH Dimensions: 74 x 6 x 120 (W x H x D) / 58g Warranty: 24 months Wall mounting plate for Ares, Poseidon2 3266/68 and other products.
DB9 LapLink Cable 2m A LapLink cable (also known as Lablink or null-printer cable) is a cable used to connect two computers directly via a cable connection. Housing: Plastic Type: Cable
DIN-Rail Box Set A mounting kit for installing HW-group devices on a DIN rail. Applications and Use: Mounting kit for installing HW-group devices with metal housing on a DIN rail. Operating environment: -30°C - 85°C / 0%RH - 100%RH Storage environment: -30°C - 60°C / 5%RH - 95%RH Dimensions: 45 x 11 x 105 (W x H x D) / 22g
Mounting Kit Screw set for mechanical mounting Applications and Use: Screw set for mechanical fastening
Mounting Plate E- 1U Rack (cabinet) mounting plate, 1U mounting for HW-group Ares and Poseidon2 devices Operating environment: -30°C - 85°C / 0%RH - 100%RH Storage environment: -30°C - 60°C / 5%RH - 95%RH Dimensions: 127 x 45 x 94 (W x H x D) / 137g Warranty: 24 months Rack (cabinet) mounting plate, 1U mounting for HW-group Ares, Poseidon2 3266/3268 and other products.
Mounting Plate L DIN Rail DIN rail mounting plate for Ares, Poseidon2 3268, and other products. Features: Metal housing Wall mounting Applications and Use: Profiles for metal-encapsulated HWg devices for wall mounting. Dimensions: 150 x 120 x 45 (W x H x D) / 65g Warranty: 24 months
Mounting Kit for Poseidon2 4002 and HWg-SMS-GW3 Applications and Use: Mounting kit for Poseidon2 4002 and HWg-SMS-GW3 Operating environment: -30°C - 85°C / 0%RH - 100%RH Storage environment: -30°C - 60°C / 5%RH - 95%RH Dimensions: 136 x 45 x 16 (W x H x D) / 165g Warranty: 24 months
Rack Shelf 1U A versatile solution for easy mounting of HW-group devices in 1U racks. Operating environment: -30°C - 85°C / 0%RH - 100%RH Storage environment: -30°C - 60°C / 5%RH - 95%RH Dimensions: 485 x 44 x 104 (W x H x D) / 597g Warranty: 24 months Housing: Metal Type: Wall mounting This shelf makes it easy to use devices in racks. You can even combine different 1U products and sensors.
Software
Manufacturer information:
HW group s. r. o.
Rumunská 26
Prague, 120 00
Czech Republic
Phone: +420 222 511 918
Email: sales@hwg.cz
Responsible person:
Didactum® Security GmbH
Im Mühlenfeld 4
48163 Münster
Deutschland
Fon:
(+49) 250 19 71 63 54 / (+49) 171 33 11 577
Email: info@didactum-security.de